Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate
Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate image
Get Latest Price Request a quote
Quick Details
Product Details
APPLICATION:
Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
1.AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
2. The aluminum alloy conductors are used in replace of singlelayer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
3.AAAC referred to have higher strength but lower conductivity than pure aluminum.Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.
STANDARDS:
ASTM B399, BS EN50183 ,BS 3242,DIN 48201,IEC 61089
All Aluminium Alloy Conductors(AAAC) ASTM B 399 | |||||||
AREA | Stranding | Wire Dia. | Approx. overall diameter |
Weight | Nominal Breaking Load |
Nom. DC resistance at 20 Deg. |
|
Nominal | Actual | ||||||
AWGorMCM | (mm2) | (mm) | (mm) | (kg/km) | (kN) | (ohm/km) | |
6 | 13.3 | 7 | 1.554 | 4.67 | 37 | 4.22 | 2.5199 |
4 | 21.15 | 7 | 1.961 | 5.89 | 58 | 6.71 | 1.5824 |
2 | 33.63 | 7 | 2.474 | 7.42 | 93 | 10.68 | 0.9942 |
1/0 | 53.48 | 7 | 3.119 | 9.36 | 148 | 16.97 | 0.6256 |
2/0 | 67.42 | 7 | 3.503 | 10.51 | 186 | 20.52 | 0.4959 |
3/0 | 85.03 | 7 | 3.932 | 11.8 | 234 | 25.86 | 0.3936 |
4/0 | 107.23 | 7 | 4.417 | 13.26 | 296 | 32.63 | 0.3119 |
250 | 126.66 | 19 | 2.913 | 14.57 | 349 | 38.93 | 0.2642 |
300 | 152.1 | 19 | 3.193 | 15.97 | 419 | 46.77 | 0.2199 |
350 | 177.35 | 19 | 3.447 | 17.24 | 489 | 52.25 | 0.1887 |
400 | 202.71 | 19 | 3.686 | 18.43 | 559 | 59.74 | 0.1650 |
450 | 228 | 19 | 3.909 | 19.55 | 629 | 67.19 | 0.1467 |
500 | 253.35 | 19 | 4.12 | 20.6 | 698 | 74.64 | 0.1321 |
550 | 278.6 | 37 | 3.096 | 21.67 | 768 | 83.80 | 0.1202 |
600 | 303.8 | 37 | 3.233 | 22.63 | 838 | 91.38 | 0.1102 |
650 | 329.25 | 37 | 3.366 | 23.56 | 908 | 97.94 | 0.1016 |
700 | 354.55 | 37 | 3.493 | 24.45 | 978 | 102.20 | 0.0944 |
750 | 380.2 | 37 | 3.617 | 25.32 | 1049 | 109.60 | 0.0880 |
800 | 405.15 | 37 | 3.734 | 26.14 | 1117 | 116.80 | 0.0826 |
900 | 456.16 | 37 | 3.962 | 27.73 | 1258 | 131.50 | 0.0733 |
1000 | 506.71 | 37 | 4.176 | 29.23 | 1399 | 146.10 | 0.0660 |
AAAC (Characteristics of A2 Conductors) IEC 61089 | |||||||
Code number | Area | Number of wires |
Diameter | Linear mass |
Rated strength |
D.C resistance | |
Wire | Cond | ||||||
mm2 | mm | mm | kg/km | kN | Ohm/km | ||
16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
40 | 46 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
100 | 115 | 19 | 2.7 | 13.9 | 316.3 | 33.95 | 0.2877 |
125 | 144 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 0.2302 |
160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
250 | 288 | 19 | 4.39 | 22 | 790.8 | 84.88 | 0.1151 |
315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
560 | 645 | 61 | 3.67 | 33 | 1778.4 | 190.14 | 0.0516 |
630 | 725 | 61 | 3.89 | 35 | 2000.7 | 213.9 | 0.0458 |
710 | 817 | 61 | 4.13 | 37.2 | 2254.8 | 241.07 | 0.0407 |
800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.68 | 0.0321 |
1000 | 1151 | 91 | 4.01 | 44.1 | 3179 | 339.53 | 0.0289 |
1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
All Aluminlum Alloy Conductors(AAAC) BS EN 50183 | |||||||
Code Name | Area | No.of wires | Diameter | Mass per unit length |
Rated strength | DC resistance | |
Wire | Cond. | ||||||
mm2 | mm | mm | kg/km | kN | Ω/km | ||
BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
HAZEL | 59.9 | 7 | 3.3 | 9.90 | 163.4 | 17.66 | 0.5494 |
PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
OAK | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 35.07 | 0.2767 |
MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
SYCAMORE | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
UPAS | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
YEW | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
TOTARA | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 146.93 | 0.0666 |
RUBUS | 586.9 | 61 | 3.5 | 31.5 | 1622.0 | 173.13 | 0.0567 |
SORBUS | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
ARAUCARIA | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
REDWOOD | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
All Aluminium Alloy Conductors (AAAC) BS EN 50183 | |||||||
Designation | Area | Stranding wire Dia. | Overall Diameter |
Nominal Breaking Load |
Nominal DC Resistance at 20ºC |
Standard Weight | |
mm2 | No | Φ | mm | kN | Ohm/km | kg/km | |
ASTER 22 | 22 | 7 | 2 | 6 | 7.15 | 1.4989 | 60 |
ASTER 34.4 | 34.4 | 7 | 2.5 | 7.5 | 11.17 | 0.9593 | 93.8 |
ASTER 54.6 | 54.6 | 7 | 3.15 | 9.45 | 17.73 | 0.6042 | 148.9 |
ASTER 75.5 | 75.5 | 19 | 2.25 | 11.3 | 24.55 | 0.4388 | 207.4 |
ASTER 117 | 117 | 19 | 2.8 | 14 | 38.02 | 0.2833 | 321.2 |
ASTER 148 | 148.1 | 19 | 3.15 | 15.8 | 48.12 | 0.2239 | 406.5 |
ASTER 181.6 | 181.6 | 37 | 2.5 | 17.5 | 59.03 | 0.1831 | 500.3 |
ASTER 228 | 227.8 | 37 | 2.8 | 19.6 | 74.04 | 0.146 | 627.6 |
ASTER 288 | 288.3 | 37 | 3.15 | 22.1 | 93.71 | 0.1154 | 794.3 |
ASTER 366 | 366.2 | 37 | 3.55 | 24.9 | 115.36 | 0.0908 | 1008.9 |
ASTER 570 | 570.2 | 61 | 3.45 | 31.1 | 185.33 | 0.0585 | 1576 |
ASTER 851 | 850.7 | 91 | 3.45 | 38 | 276.47 | 0.0394 | 2360.7 |
ASTER 1144 | 1143.5 | 91 | 4 | 44 | 360.22 | 0.0293 | 3173.4 |
ASTER 1600 | 1595.9 | 127 | 4 | 52 | 502.72 | 0.021 | 4427.5 |
AAAC 6201- All Aluminium Alloy Conductor AS 1531 | |||||||
Code Name | Strands/ Wire Diameter |
Overall Diameter (Approx) |
Calculated Equivalent Aluminium Area |
Sectional Area |
Approx. Mass |
Calculated Minimum Breaking Load |
D.C.Resistence at 20ºC |
mm | mm | mm2 | mm2 | kg/km | kN | Ω/km | |
Agate | 7/1.75 | 5.25 | 14.3 | 16.84 | 46 | 4.71 | 1.972 |
Amethyst | 7/2.25 | 6.75 | 23.7 | 27.83 | 76 | 7.78 | 1.194 |
Diamond | 7/2.50 | 7.50 | 29.3 | 34.36 | 94 | 9.64 | 0.967 |
Dolomite | 7/2.75 | 8.25 | 35.4 | 41.58 | 114 | 11.6 | 0.799 |
Emerald | 7/3.00 | 9.00 | 42.2 | 49.48 | 136 | 13.9 | 0.671 |
Garnet | 7/3.75 | 11.3 | 65.8 | 77.28 | 211 | 21.7 | 0.43 |
Jade | 7/4.50 | 13.5 | 94.8 | 111.3 | 304 | 31.2 | 0.298 |
Jasper | 7/4.75 | 14.3 | 106 | 124.0 | 340 | 34.8 | 0.268 |
Opal | 19/3.25 | 16.3 | 134 | 157.6 | 433 | 44.2 | 0.212 |
Patronite | 19/3.50 | 17.5 | 155 | 182.80 | 502 | 51.3 | 0.183 |
Pearl | 19/3.75 | 18.8 | 178 | 209.8 | 577 | 58.8 | 0.159 |
Ruby | 37/3.00 | 21.0 | 221 | 261.60 | 720 | 73.5 | 0.128 |
Ruthenium | 37/3.25 | 22.8 | 260 | 307.00 | 845 | 86.1 | 0.109 |
Rutile | 19/4.75 | 23.8 | 285 | 336.7 | 925 | 94.4 | 0.09991 |
Sapphire | 37/3.75 | 26.3 | 345 | 408.50 | 1125 | 115 | 0.0819 |
Spinel | 61/3.25 | 29.3 | 427 | 506.10 | 1396 | 135 | 0.0662 |
Tantalum | 61/3.50 | 31.5 | 495 | 586.90 | 1620 | 156 | 0.0572 |
Topaz | 61/3.75 | 33.8 | 568 | 673.40 | 1858 | 179 | 0.0498 |
Zircon | 91/4.50 | 49.5 | 1220 | 1447 | 3997 | 384 | 0.0232 |
We are China Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Conductor Products
Bare Conductor AAAC All Aluminum Alloy Stranded Conductor
AAAC Cable AAAC Conductor to ASTM B399
3/0AWG Amherst AAAC Aluminum Alloy Bare Conductor Overhead Cable
IEC61089 All Aluminum Alloy Condcutor AAAC 450
All Aluminum Alloy Conductor Cables (AAAC)
Popular Aluminum Alloy Conductor Products
132kv Transmission Lines Aluminum Alloy Conductor AAAC Hazel 500mm2
Bare Stranded All Aluminium Alloy AAAC Deodar Conductor with BS 50183 Standard
Cable Nu Almelec 1X75.5 mm2 Aster Conductor
2AWG 6201 AAAC Aluminum Alloy Conductor
IEC61089 All Aluminum Alloy Condcutor AAAC 315
British Sizes 3242 All Aluminum Alloy Condcutor AAAC Upas
Popular Conductor Products
ASTM B232 ACSR Finch Conductor Overhead Bare Conductor
Electrical Cable Low Voltage (LV) PVC/XLPE Insulated Armoured
Hawk 477 Mcm Bare Electric Aluminum Conductor ACSR
Bare Conductor for Overhead Conductor ACSR 100m2 Dog BS-215 Part 2
BS Standard Bare Greased Conductor AAC Conductor
Popular renmincable Products
Copper Conductor Insulated Steel Tape Armored PVC Sheathed Power Cable
Solid Copper Wire Thw Thwn Electrical Cable
Overhead Hard Drawn Bare Aluminum Sca Conductor ACSR Conductor
Factory Supply Reasonable Price Bare AAC Conductor Aluminum Cable
120mm 4 Core Steel Tape Armoured Sta Underground Electric Cable
150mm2 Bare Aluminium Stranded Overhead Cable AAAC Conductor
Tags: AAAC Conductor, Aluminum Alloy Conductor, Conductor, renmincable