Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Setter
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Setter image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Specification
Duplex service drop | |||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
Bare | OD | ||||||||
AAC | |||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
AAAC | |||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
ACSR | |||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
DESCRIPTION | INSULATED PHASE CONDUCTORS | Average Insulation Thickness | ||||
Type | Nominal cross-section area | Wire Number in the conductor | Max. resistance at 20 o C | Average diameter of conductors | Rated Strength | |
mm 2 | Number | Ohm/km | Mini mm Max. mm | Mini KN | mm | |
PHASE, NEUTRAL, and PUBLIC LIGHTING |
16 | 7 | 1.910 | 4.6 5.1 | 1.9 | 1.2 |
25 | 7 | 1.200 | 5.8 6.3 | 3.0 | 1.4 | |
35 | 7 | 0.868 | 6.8 7.3 | – | 1.6 | |
50 | 7 | 0.641 | 7.9 8.4 | – | 1.6 | |
70 | 12 | 0.443 | 9.7 10.2 | – | 1.8 | |
95 | 19 | 0.320 | 11.0 12.0 | – | 1.8 | |
120 | 19 | 0.253 | 12.0 13.1 | – | 1.8 | |
150 | 19 | 0.206 | 13.9 15.0 | – | 1.7 | |
PORTER | 54.6 | 7 | 0.630 | 9.2 9.6 | 16.6 | 1.6 |
70 | 7 | 0.500 | 10.0 10.2 | 20.5 | 1.5 | |
95 | 19 | 0.343 | 12.2 12.9 | 27.5 | 1.6 |
We are China Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Setter manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable 6 AWG Setter Products
Popular Duplex 6 AWG Setter Cable Products
Popular Factory Price Duplex Service Drop Products
Factory Price Duplex Service Drop Cable ABC Cable 2 AWG Chow
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Dachshund
Factory Price Duplex Service Drop Cable ABC Cable 6AWG Collie
Factory Price Duplex Service Drop Cable ABC Cable 2AWG Doberman
Factory Price Duplex Service Drop Cable ABC Cable 2 AWG Schnauzer
Factory Price Duplex Service Drop Cable ABC Cable 1AWG Airedale
Popular huatongcable Products
600V XLPE Copper Conductor PVC / XLPE Insulated Electric Power Cable
High Voltage AAC/ACSR Cable to IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110 Standard
ABC Cable (duplex, triplex, quadruplex service drop) , XLPE Insulation
U160bp Insulator Suspension Insulator with Zinc Sleeve
Competitive Price! ACSR Stranded Conductor, AAC/AAAC /ACSR /Acss /Aacsr /Gsw Bare Conductor
15kv, 30kv 1c500sqmm Power Cable for Nicaragua
Tags: Cable 6 AWG Setter, Duplex 6 AWG Setter Cable, Factory Price Duplex Service Drop, huatongcable