0.6/1kv, 1.8/1kv, 3.6/6kv, 6/10k, 8.7/15kv, 12/20kv, 18/30kv, 26/35kv XLPE Cable
0.6/1kv, 1.8/1kv, 3.6/6kv, 6/10k, 8.7/15kv, 12/20kv, 18/30kv, 26/35kv XLPE Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Power Cable
Standards
Products can be manufactured according to GB standard, IEC standard, ASTM standard, BS standard and DIN and other standard and customers` specific requirements.
Specification
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
4. PVC or XLPE sheathed.
5. Number of cable cores: one core (Single core),two cores(Double cores),three cores, four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core), five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Number of Cores & Nominal Cross-section Area
Number of Cores | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Section Area (mm2) | 4 – 500 | 2.5 – 500 | 2.5 – 300 | 4 – 300 | 2.5 – 300 | 2.5 -300 | 4 – 300 | 2.5 – 95 |
Installation:
1. The installation temperature should not over 20ºC, If the ambient temperature is lower than 0ºC, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 35kv D.C.
In air:
1. As the single core cable laying in parallel, the distance between the cable’s center is 2 times (for cables which cross section area of conductor ≤185mm2) and
90mm (for cables which cross sectional area of conductor≥240mm2)
2. Ambient temperature: 30ºC
3. Max. temperature of conductor: 70ºC
4. Rating factors of current rating for ambient temperature:
Air temperature | 20ºC | 25ºC | 35ºC | 40ºC | 45ºC |
Rating factors | 1.12 | 1.06 | 0.94 | 0.87 | 0.79 |
Direct in ground:
1. When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.
2. Ambient temperature: 25ºC.
3. Max. temperature of conductor: 70ºC.
4. Soil thermour resistivity: 1.0ºC. m/w.
5. Depth: 0.7m
6. Rating factors under different ambient temp.:
Air temperature | 15ºC | 20ºC | 30ºC | 35ºC |
Rating factors | 1.11 | 1.05 | 0.94 | 0.88 |
PVC Insulation Electric Cable
TYPE | Description of Cable |
Main Applications |
|
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
XLPE Insulated electric cable
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV |
YJLV ZR-YJLV |
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable |
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable |
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
We are China 0.6/1kv, 1.8/1kv, 3.6/6kv, 6/10k, 8.7/15kv, 12/20kv, 18/30kv, 26/35kv XLPE Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminium Core Products
Aluminium Core PVC Sheath Power Cable Underground Used
1kv/3kv Aluminium Core Power Cable IEC60502-1 61304 60754 Standard
Aluminium Core with Insulation Overhead Cable 2*10mm2 ABC
Popular huatongcable Products
Aluminum - Clad Steel Conductors (ACS) SA1a/SA1b IEC61089 DIN 48201
ASTM B399 AAAC Cable All Aluminium Alloy Conductors
Overhead Triplex Service Drop Zuzara Aerial Bundled Cable for Transmission Line
8000 Series Aluminum Alloy Concentric Cable
Aluminum Conductor, Aluminum Clad Steel Reinforced, ACSR for Overhead Telecommunication
Bare Aluminum Conductor Steel Reinforced ASTM Standard ACSR Cable
Popular IEC60502-1 61304 60754 Standard Products
1kv/3kv Aluminium Core Power Cable IEC60502-1 61304 60754 Standard
Popular Power Cable Products
35kv 1*185mm2 Sta Armoured XLPE Insulation Power Cable
95mm 120mm 110kv High Voltage XLPE Insulated 3 Core Underground Power Cable
Hot Selling PVC Insulated Copper Wire Electric Power Cable
0.6/1kv Low Voltage Steel Wire Armoured PVC/XLPE Insulated Jacket Electric Power Cable
Aluminum Alloy AAAC Conductor 500mm2 800mm2 1000mm2 Overhead Cable
Tags: Aluminium Core, huatongcable, IEC60502-1 61304 60754 Standard, Power Cable