0.6/1kv 16mm 4 Core Copper PVC Insulated Swa Armored Cable

China 
                        0.6/1kv 16mm 4 Core Copper PVC Insulated Swa Armored Cable
                      manufacture and supplier

0.6/1kv 16mm 4 Core Copper PVC Insulated Swa Armored Cable image

Get Latest Price Request a quote

Quick Details

0.6/1kv 16mm 4 Core Copper PVC Insulated Swa Armored Cable

16mm armored cable

Jytop

YJV

ISO

Copper/ Aluminum

Round Wire

PVC

PVC

DC & AC

Low and Medium Voltage Cable

Construction, Industrial, Power Station

0.6/1kv

4 Veff Kv

-20 Deg

-40deg~ +90deg

18 X Od

JYTOP

Reel or Drum

4X150sq. Mm

Zhengzhou, China

8544492100

Product Details

0.6/1kv 16mm 4 Core Copper PVC insulated SWA Armored Cable 

Application

Armored copper cable is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Construction

 

   
Conductor Aluminium conductor, round stranded compressed (RM).
Insulation XPLE compound, UV-resistant.
Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth.

Electrical Properties

Rated Voltage 0.6/1kV
Test Voltage 4 Veff kV
Minimum Laying Temperature -20°C
Operating Temperature -40°C~ +90°C
Maximum Short-circuit Temperature 250°C
Maximum Conductor Temperature 80°C
Minimum Bending Radius 18×OD

Construction Parameters

BS 7870

Number of Cores x Nominal Cross Section Overall Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.×mm² mm Kg/Km Ω/Km KN A
1×16 RM 8.0 74 1.910 2.5 72
1×25 RM 9.0 106 1.200 4.0 107
1×35 RM 10.5 138 0.868 5.5 132
1×50 RM 11.8 182 0.641 8.0 165
1×70 RM 13.0 252 0.443 10.7 205
1×95 RM 15.4 333 0.320 13.7 240
1×120 RM 17.0 408 0.253 18.6 290
1×150 RM 19.0 502 0.206 23.2 334
1×185 RM 21.0 611 0.164 28.7 389
1×240 RM 24.0 801 0.125 37.2 467
2×16 RM 15.6 147 1.910 2.5 72
2×25 RM 18.0 208 1.200 4.0 107
2×35 RM 20.0 277 0.868 5.5 132
2×50 RM 23.5 361 0.641 8.0 165
2×70 RM 25.4 505 0.443 10.7 205
2×95 RM 30.3 666 0.320 13.7 240
2×150 RM 38.0 1004 0.206 23.2 334
4×16 RM 18.8 286 1.910 2.5 72
4×25 RM 21.2 430 1.200 4.0 107
4×35 RM 24.1 553 0.868 5.5 132
4×50 RM 27.8 746 0.641 8.0 165
4×70 RM 31.8 1009 0.443 10.7 205
4×95 RM 37.8 1332 0.320 13.7 240
4×120 RM 54.4 1632 0.253 18.6 290
4×50 + 1×25 RM 31.9 814 0.641/1.200 8.0/4.0 165/107
4×50 + 1×35 RM 31.9 845 0.641/0.868 8.5/5.5 165/132
4×70 + 1×25 RM 36.0 1105 0.443/1.200 10.7/4.0 205/107
4×70 + 2×25 RM 40.0 1217 0.443/1.200 10.7/4.0 205/107
4×95 + 1×25 RM 41.8 1438 0.320/1.200 13.7/4.0 240/107
4×95 + 2×25 RM 42.0 1544 0.320/1.200 13.7/4.0 240/107
4×120 + 1×25 RM 59.0 2050 0.253/1.200 18.6/4.0 290/107

Other cross-sections can be offered upon request.

TNB Specification(IEC 60502)

Number of Cores x Nominal Cross Section Overal Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.×mm² mm Kg/Km Ω/Km KN A
1×16+1×25 RM 15.3 160 1.910 2.5 72
3×16+1×25 RM 19.0 290 1.200 4.0 107
3×25+1×25 RM 23.2 400 0.868 5.5 132
3×35+1×25 RM 25.6 500 0.641 8.0 165
3×50+1×35 RM 30.0 680 0.443 10.7 205
3×70+1×50 RM 34.9 920 0.320 13.7 240
3×95+1×70 RM 40.6 1270 0.253 18.6 290
3×120+1×70 RM 44.1 1510 0.206 23.2 334
3×150+1×95 RM 49.2 1870 0.164 28.7 389
3×185+1×120 RM 54.9 2340 0.125 37.2 467
3×25+1×25+1×16 RM 23.2 470 1.910 2.5 72
3×35+1×25+1×16 RM 25.6 560 1.200 4.0 107
3×50+1×35+1×16 RM 30.0 740 0.868 5.5 132
3×70+1×50+1×16 RM 34.9 980 0.641 8.0 165
3×95+1×70+1×16 RM 40.6 1330 0.443 10.7 205
3×120+1×70+1×16 RM 44.1 1580 0.320 13.7 240
3×150+1×95+1×16 RM 49.2 1940 0.206 23.2 334
3×185+1×120+1×16 RM 54.9 2410 1.910 2.5 72

Other cross-sections can be offered upon request.

HD 626 S1

number of cores x nominal cross section outer diameter total weight max. conductor- resistance min. breaking load of conductor strand current rating in the air 1)
mm² ca. mm ca. kg/km Ohm/km kN A
2x 16 RM 15.6 147 1.910 2.5 72
2x 25 RM 18.0 208 1.200 4.0 107
2x 35 RM 20.0 277 0.868 5.5 132
2x 50 RM 23.5 361 0.641 8.0 165
4x 16 RM 18.8 286 1.910 2.5 72
4x 25 RM 21.2 430 1.200 4.0 107
4x 35 RM 24.1 553 0.868 5.5 132
4x 50 RM 27.8 746 0.641 8.0 165
4x 70 RM 31.8 1009 0.443 10.7 205
4x 95 RM 37.8 1332 0.320 13.7 240
4x 120 RM 54.4 1632 0.253 18.6 290
4x 35 + 1x 35 RM 30.0 694 0.868/0.868 5.5/5.5 132/132
4x 50 + 1x 25 RM 31.9 814 0.641/1.200 8.0/4.0 165/107
4x 50 + 1x 35 RM 31.9 845 0.641/0.868 8.5/5.5 165/132
4x 70 + 1x 25 RM 36.0 1105 0.443/1.200 10.7/4.0 205/107
4x 70 + 2x 25 RM 40.0 1217 0.443/1.200 10.7/4.0 205/107
4x 70 + 1x 35 RM 36.2 1150 0.443/0.868 10.7/5.5 205/132
4x 70 + 2x 35 RM 40.1 1289 0.443/0.868 10.7/5.5 205/132
4x 95 + 1x 25 RM 41.8 1438 0.320/1.200 13.7/4.0 240/107
4x 95 + 1x 35 RM 41.8 1467 0.320/0.868 13.7/5.5 240/132
4x 95 + 2x 25 RM 42.0 1544 0.320/1.200 13.7/4.0 240/107

Other cross-sections can be offered upon request.

NFC 33-209

Number of Cores x Nominal Cross Section Overal Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.×mm² mm Kg/Km Ω/Km KN A
2×10 RM 12.8 93 3.080 1.5 38
4×10 RM 15.4 183 3.080 1.5 38
2×16 RM 14.8 129 1.910 2.3 72
2×16 RN + 2×1.5 RE 14.8 176 1.910/12.100 2.3 72
4×16 RM 17.8 257 1.910 2.3 72
4×16 RN + 2×1.5 RE 17.8 304 1.910/12.100 2.3 72
2×25 RM 18.0 202 1.200 3.8 107
2×25 RM + 2×1.5 RE 18.0 249 1.200/12.100 3.8 107
4×25 RM 21.7 404 1.200 3.8 107
4×25 RM + 2×1.5 RE 21.7 451 1.200/12.100 3.8 107
2×35 RM 20.8 269 0.868 5.2 132
2×35 RM + 2×1.5 RE 20.8 316 0.868/12.100 5.2 132
4×35 RM 25.1 539 0.868 5.2 132
4×35 RM + 2×1.5 RE 25.1 586 0.868/12.100 5.2 132
2×50 RM 23.4 352 0.641 7.6 165
2×50 RM + 2×1.5 RE 23.4 399 0.641/12.100 7.6 165
1×54.6 RM + 3×25 RM 21.7 507 0.630/1.200 3.8 107
1×54.6 RM + 3×25 RM + 1×16 RM 24.3 573 0.630/1.200/1.910 3.8/2.3 107/72
1×54.6 RM + 3×25 RM + 2×16 RM 29.7 639 0.630/1.200/1.910 3.8/2.3 107/72
1×54.6 RM + 3×25 RM + 3×16 RM 31.1 705 0.630/1.200/1.910 3.8/2.3 107/72
1×54.6 RM + 3×35 RM 25.1 615 0.630/0.868 5.2 132
1×54.6 RM + 3×35 RM + 1×16 RM 28.1 680 0.630/0.868/1.910 5.2/2.3 132/72
1×54.6 RM + 3×35 RM + 2×16 RM 34.3 748 0.630/0.868/1.910 5.2/2.3 132/72
1×54.6 RM + 3×35 RM + 3×16 RM 35.9 814 0.630/0.868/1.910 5.2/2.3 132/72
1×54.6 RM + 3×35 RM + 1×25 RM 28.1 714 0.630/0.868/1.200 5.2/3.8 132/107
1×54.6 RM + 3×50 RM 28.2 741 0.630/0.641 7.6 165
1×54.6 RM + 3×50 RM + 1×16 RM 31.6 806 0.630/0.641/1.910 7.6/2.3 165/72
1×54.6 RM + 3×50 RM + 2×16 RM 38.6 875 0.630/0.641/1.910 7.6/2.3 165/72
1×54.6 RM + 3×50 RM + 3×16 RM 40.4 940 0.630/0.641/1.910 7.6/2.3 165/72
1×54.6 RM + 3×50 RM + 1×25 RM 31.6 841 0.630/0.641/1.200 7.6/3.8 165/107
1×54.6 RM + 3×70 RM 33.0 950 0.630/0.443 10.2 205
1×54.6 RM + 3×70 RM + 1×16 RM 37.0 1014 0.630/0.443/1.910 10.2/2.3 205/72
1×54.6 RM + 3×70 RM + 2×16 RM 45.2 1083 0.630/0.443/1.910 10.2/2.3 205/72
1×54.6 RM + 3×70 RM + 3×16 RM 47.3 1148 0.630/0.443/1.910 10.2/2.3 205/72
1×54.6 RM + 3×70 RM + 1×25 RM 37.0 1048 0.630/0.443/1.200 10.2/3.8 205/107
1×54.6 RM + 3×70 RM + 2×25 RM 45.2 1150 0.630/0.443/1.200 10.2/3.8 205/107
1×54.6 RM + 3×70 RM + 3×25 RM 47.3 1250 0.630/0.443/1.200 10.2/3.8 205/107
1×54.6 RM + 3×95 RM 37.4 1176 0.630/0.320 13.5 240
1×54.6 RM + 3×95 RM + 1×16 RM 41.9 1243 0.630/0.320/1.910 13.5/2.3 240/72

Other cross-sections can be offered upon request.

AS/NZS 3560 Part 1

Number of Cores x Nominal Cross Section Overall Diameter Weight Minimum Breaking Load Current Rating
No.×mm² mm Kg/Km KN A
2×16 RM 15.0 140 4.4 78
2×25 RM 17.6 210 7.0 105
2×35 RM 19.6 270 9.8 125
2×50 RM 22.8 370 11.4 150
2×95 RM 30.6 680 15.3 230
3×25 RM 19.0 310 8.8 97
3×35 RM 21.1 410 9.8 120
3×50 RM 24.6 550 11.4 140
4×16 RM 18.1 290 8.8 74
4×25 RM 21.2 410 14.0 97
4×35 RM 23.7 550 19.6 120
4×50 RM 27.5 740 28.0 140
4×70 RM 31.9 1000 39.2 175
4×95 RM 36.9 1370 53.2 215
4×120 RM 40.6 1690 67.2 250
4×150 RM 43.9 2020 84.0 280

Other cross-sections can be offered upon request.


We are China 0.6/1kv 16mm 4 Core Copper PVC Insulated Swa Armored Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 11kv Armored Cable Products

11kv Aluminum Conductor XLPE Insulated PVC Cable 1X150sq. mm

Middle Voltage XLPE Cable with Copper Conductor Aluminum Wire Armoured

6.35/11kv Aluminum Conductor XLPE Insulated Power Cable

Mv Armored Cable 11kv XLPE Insulation Steel Tape Armored Cable

6.35/11kv Aluminum Conductor XLPE Insulation Tape Armored Cable

Mv 6.35/11kv XLPE Insulation Steel Tape Armored Power Cable

Popular jytopcable Products

Tinner Copper Thhn Wire with Nylon Jacket

Flexible Wire with Copper Conductor

450/750V PVC Insulated PVC Sheathed Electric Wire with Flexible Conductor

H05V-K PVC Insulated Conductor with Fine Wired

Bare Conductor AAC with Standard DIN48201

AAC 35mm2 All Aluminum Conductor to DIN 48201

Popular PVC Insulated Cable Products

0, 6/1 Kv Cu Conductor PVC/XLPE Insulated Power Cable

ISO CCC TUV CB Approved Wire XLPE Insulation PVC Sheathed Power Cable

0.6/1kv XLPE Swa Power Cable

Yvz2V-U, Yvz2V-R, Nyry Galvanized Steel Armoured Underground Power Cable

150mm Copper Conductor XLPE Insulated Armoured Power Cable

450/750V PVC Used as Power

Popular Steel Wire Armoured Cable Products

10mm 16mm 25mm 3 Core Steel Wire Armoured Cable Swa Copper XLPE Electrical Wire

Yjv Swa Steel Wire Armoured Copper/Aluminium Conductor XLPE/PVC Insulated Electrical Power Cables

Copper Conductor XLPE Insulated Armoured Electrical Cable

0.6/1kv Type Mv PVC/Swa/PVC 70mm 4 Core Copper Cable with Armored

3X4mm2 Copper Conductor XLPE Insulated Armored Electrical Cable

0.6/1kv PVC/Swa/PVC 35mm 4 Core Copper Armoured Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION