Quick Details
Product Details
ASTM BS Standard 0.6/1kv pvc/xlpe/pe insulatedDuplex aerial bundle cable, abc cable
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
A, 2, 3, 4 power cores consisting of strandard aluminium conductor, insulated with XLPE or PVC, PE.
B, One sheath lighting aluminium conductor with XLPE insulation(optional)
C, One messenger Al-alloy (bare or covered)
It meets or exceeds the following specification:
A, Aluminium wire, 1350-H19 for electrical purposes.
B, Aluminium conductor, concentric-lay-stranded.
C, Aluminium conductor, concentric-lay-stranded, coated steel reinforgorced(ACSR, AAC, AAAC)
D, Concentric-lay stranded 6201-T81 conductors.
E, Compressed Round Stranded Aluminium consuctors using single input wire.
Specifications:
Conductor: Aluminum
Insulation: PVC, XLPE, PE
Application: Overhead line
Core: 2.3, 4 core( Duplex, triplex, quoduplex)
Code word |
AWG or kcmil |
Bare Neutral Messenger | Phase Conductor | Weight Kg/km |
Allowable Ampacities(A) |
|||||||
ACSR | Rated strength Ibs. | AAC | Insul Thick. mm |
XLPE |
PE |
|||||||
Number | Dia mm | Number | Dia mm | Number | Dia mm | |||||||
Setter | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 111 | 85 | 70 |
Bull | 1*1/0AWG+1*1/0AWG | 1 | 3.37 | 6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 427 | 205 | 160 |
Shepherd | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 113 | 85 | 70 |
Eskimo | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 171 | 115 | 90 |
Terrier | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 173 | 115 | 90 |
Chow | 1*2AWG+1*2AWG | 1 | 2.67 | 6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 266 | 150 | 120 |
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Number and nominal diameter of wires mm |
||||||||||
Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
+Auxiliary conductors or cores only |
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
Table 02
1 | 2 |
Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
54.6 | 25,35,50,70,95 |
70 | 70,95,120 |
95 | 95,120,150 |
—————————————————————————————————————————–
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Table 03
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |
We are China 0.6/1kv ABC Cable, Aerial Bundle Cable, XLPE Insulated ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6/1kv ABC Cable Products
ASTM ABC XLPE PE PVC Insulated Aerial Bundled Electrical Cable
Duplex Service Drop Aerial Bundled Cable XLPE Insulated ABC Cable
Competitive Price of 0.6/1kv Aerial Bundled Cable ABC Cable
0.6-1kv XLPE Insulated Service Aerial Bundled Aluminum Overhead ABC Cable
XLPE PE PVC Insulated Aerial Bundled Electrical ABC Cable
Low Voltage Aerial Bundled Cable
Popular ABC Cable Products
ABC Cable Overhead Cable Aerial Bundled Cable
People's Cable Group of Best Selling Medium Voltage Aerial Bundled Cable
IEC BS Standard Single Core PE/XLPE Insulated Overhead ABC Cable
Low Voltage PE Insulated 6 Gauge ABC Cable
0.6-10kv Aluminum Overhead ABC Power Cable
1/0 AWG 2/0 AWG 4/0 AWG Service Drop Wire Twisted Aluminum ABC Cable
Popular Aerial Bundled Cable Products
High Quality Competitive Price of Aerial Bundled Cable ABC Cable
Aerial Bundled Cable XLPE Insulated 2*35mm2 - AS/NZS 3560.1
Al XLPE ABC Cable (Aerial Bundled Cable)
High Quality 70mm2/54.6mm2 Aerial Bundled Cable
ISO9001 16mm2 25mm2 ABC Aerial Bundled Cable Electrical Wire with Factory Price
1kv XLPE/PVC Insulated ABC Aerial Bundle Cable From Maufacturer
Popular jytopcable Products
Middle Voltage XLPE Cable with Copper Conductor Aluminum Wire Armoured
All Aluminum Alloy Conductor AAAC Cable Bare Aluminium Conductor
N2xcy/N2xcwy/Na2xcwy Cu/PVC Power Cable to DIN/VDE 0276
15kv Aluminum Stw Cable for Size of 3X70mm2
AAC Conductor All Aluminum Conductor 70mm 185mm DIN
N2xsy Low Voltage XLPE/PVC Insulated Copper Wire Armoured Power Cable N2xry
Tags: 0.6/1kv ABC Cable, ABC Cable, Aerial Bundled Cable, jytopcable