Quick Details
Product Details
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
A, 2, 3, 4 power cores consisting of strandard aluminium conductor, insulated with XLPE or PVC, PE.
B, One sheath lighting aluminium conductor with XLPE insulation(optional)
C, One messenger Al-alloy (bare or covered)
It meets or exceeds the following specification:
A, Aluminium wire, 1350-H19 for electrical purposes.
B, Aluminium conductor, concentric-lay-stranded.
C, Aluminium conductor, concentric-lay-stranded, coated steel reinforgorced(ACSR, AAC, AAAC)
D, Concentric-lay stranded 6201-T81 conductors.
E, Compressed Round Stranded Aluminium consuctors using single input wire.
Specifications:
Conductor: Aluminum
Insulation: PVC, XLPE, PE
Application: Overhead line
Core: 2.3, 4 core( Duplex, triplex, quoduplex)
|
Code word |
AWG or kcmil |
Bare Neutral Messenger | Phase Conductor | Weight Kg/km |
Allowable Ampacities(A) |
|||||||
| ACSR | Rated strength Ibs. | AAC | Insul Thick. mm |
XLPE |
PE |
|||||||
| Number | Dia mm | Number | Dia mm | Number | Dia mm | |||||||
| Setter | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 111 | 85 | 70 |
| Bull | 1*1/0AWG+1*1/0AWG | 1 | 3.37 | 6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 427 | 205 | 160 |
| Shepherd | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 113 | 85 | 70 |
| Eskimo | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 171 | 115 | 90 |
| Terrier | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 173 | 115 | 90 |
| Chow | 1*2AWG+1*2AWG | 1 | 2.67 | 6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 266 | 150 | 120 |
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01
| Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
| Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
| Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
| 25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
| 35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
| 50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
| 70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
| 95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
| 120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
| 150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
| Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
| 25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
| 16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
| 25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Number and nominal diameter of wires mm |
||||||||||
| Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
| 70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
| +Auxiliary conductors or cores only | ||||||||||
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
Table 02
| 1 | 2 |
| Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
| 54.6 | 25,35,50,70,95 |
| 70 | 70,95,120 |
| 95 | 95,120,150 |
—————————————————————————————————————————–
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Table 03
| Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
| Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
| Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
| 25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
| 35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
| 50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
| 70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
| 95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
| 120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
| 150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
| Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
| 25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
| 16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
| 25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
| 25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
| 35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
| 50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
| 54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
| 70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |
|
We are China 0.6/1kv Aerial Bundle Cable (IEC, ASTM, Sans, NFC Standards) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Products
Factory Price Overhead Cable AAC AAAC ACSR Conductor Service Drop ABC Cable Price
Supply, deliver, string and set to work 50mmx3C+50mm Aerial Bundled Cable (ABC)
High Quality ABC-PVC/XLPE Insulated Aerial Bundled Cable
High Quality 33kv Medium Voltage Sevice Drop ABC Aerial Bundle Cable
Astmb-232 4/0AWG ABC 3 Phase Twist Aluminum Duplex Aerial Bundle Overhead Cable
0.6/1kv XLPE Insulated Duplex/ Triplex Service Drop Aerial Bundle Overhead ABC Cable
Popular ABC Cable Products
Duplex Service Drop AAAC Alloy Neutral Messenger Cable
0.6/1kv Low Voltage Twisted Aluminum Core XLPE Insulated ABC Cable
Aerial Bundled Cable ABC Cable Used for Overhead Power Transmission
Copper Wire Overhead ABC Cable Aerial Bundled XLPE Cable
0.6/1kv XLPE Insulated ABC Cable
Low Voltage 3X50+54.6mm2 Overhead Aluminum ABC Cable NFC 33209 Standard
Popular Aerial Bundle Cable Products
Overhead Transmission Twisted ABC Aerial Bundled Cable
Overhead Aluminum Conductor XLPE Insulation ABC Cable
XLPE Insulation Aluminum Alloy Cable
Aerial Bundle Cable /Service Drop Cable/Overhead Cable
Aluminum Conductor Service Drop, Aerial Bundle XLPE ABC Cable
Low Voltage Overhead Aluminum Twisted Selfsupporting ABC Cable 2 Core
Popular jytopcable Products
Medium Voltage 11kv Cable, Swa Cable, Single Core Cable
Copper Conductor Armoured XLPE 2xy 2xyby 2xyry Cable 0.6/1kv
Mv XLPE Insulation Power Cable with Copper Wire Shield and Steel Tape Armored
XLPE Insulation Swa Steel Wire Armoured Underground Electrical Power Cable
Overhead Transmission Line ABC Aerial Bunched Cables
Tags: ABC, ABC Cable, Aerial Bundle Cable, jytopcable