0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable
0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Rated Voltage: 0.6/1kv Conductor material: copper
Insulation material: PVC Sheath Material: PVC
Core: 1,2,3, 4,5, 3+1,3+2,4+1 Certificate: ISO, CCC,BV
Standard: GB/T12706-2002
Trademark: jytop or OEM
Installation temperature: not lower than 0°C
Operating Temperature: 70°C Max
Short-circuit Max. Conductor Temperature: 160°C
Short-circuit Max : 5s
Bending radius: not be less than 15 times of cable outer diameter
Application: Being laid indoors, in tunnels or in ducts, unable to bear mechanical external force.
Technical data of 0.6/1KV, Single core, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 1x10mm2 | RM | 1.0 | 0.2 | 1.8 | 12.9 | 3.08 |
| 1x16mm2 | RM | 1.0 | 0.2 | 1.8 | 13.9 | 1.91 |
| 1x25mm2 | RM | 1.2 | 0.2 | 1.8 | 14.3 | 1.20 |
| 1x35mm2 | RM | 1.2 | 0.2 | 1.8 | 15.5 | 0.868 |
| 1x50mm2 | RM | 1.4 | 0.2 | 1.8 | 17.2 | 0.641 |
| 1x70mm2 | RM | 1.4 | 0.2 | 1.8 | 19.0 | 0.443 |
| 1x95mm2 | RM | 1.6 | 0.2 | 1.8 | 21.3 | 0.320 |
| 1x120mm2 | RM | 1.6 | 0.2 | 1.8 | 22.9 | 0.253 |
| 1x150mm2 | RM | 1.8 | 0.2 | 1.8 | 24.9 | 0.206 |
| 1x185mm2 | RM | 2.0 | 0.2 | 1.8 | 27.1 | 0.164 |
| 1x240mm2 | RM | 2.2 | 0.2 | 1.8 | 30.2 | 0.125 |
| 1x300mm2 | RM | 2.4 | 0.5 | 2.0 | 35.2 | 0.100 |
| 1x400mm2 | RM | 2.6 | 0.5 | 2.1 | 38.8 | 0.0778 |
| 1x500mm2 | RM | 2.8 | 0.5 | 2.2 | 43.0 | 0.0605 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, two cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 2×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 12.9 | 18.1 |
| 2×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.7 | 12.1 |
| 2x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 15.5 | 7.41 |
| 2x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.5 | 4.61 |
| 2x10mm2 | RM | 1.0 | 0.2 | 1.8 | 19.1 | 3.08 |
| 2x16mm2 | RM | 1.0 | 0.2 | 1.8 | 21.2 | 1.91 |
| 2x25mm2 | SM | 1.2 | 0.2 | 1.8 | 18.6 | 1.20 |
| 2x35mm2 | SM | 1.2 | 0.2 | 1.8 | 20.1 | 0.868 |
| 2x50mm2 | SM | 1.4 | 0.2 | 1.8 | 22.4 | 0.641 |
| 2x70mm2 | SM | 1.4 | 0.5 | 2.0 | 26.9 | 0.443 |
| 2x95mm2 | SM | 1.6 | 0.5 | 2.1 | 30.3 | 0.320 |
| 2x120mm2 | SM | 1.6 | 0.5 | 2.2 | 32.6 | 0.253 |
| 2x150mm2 | SM | 1.8 | 0.5 | 2.3 | 35.5 | 0.206 |
| 2x185mm2 | SM | 2.0 | 0.5 | 2.5 | 39.1 | 0.164 |
| 2x240mm2 | SM | 2.2 | 0.5 | 2.7 | 43.6 | 0.125 |
| 2x300mm2 | SM | 2.4 | 0.5 | 2.8 | 47.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, three cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 3×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.4 | 18.1 |
| 3×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.3 | 12.1 |
| 3x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.1 | 7.41 |
| 3x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 4.61 |
| 3x10mm2 | RM | 1.0 | 0.2 | 1.8 | 20.0 | 3.08 |
| 3x16mm2 | RM | 1.0 | 0.2 | 1.8 | 22.3 | 1.91 |
| 3x25mm2 | SM | 1.2 | 0.2 | 1.8 | 21.3 | 1.20 |
| 3x35mm2 | SM | 1.2 | 0.2 | 1.8 | 23.2 | 0.868 |
| 3x50mm2 | SM | 1.4 | 0.2 | 1.9 | 26.2 | 0.641 |
| 3x70mm2 | SM | 1.4 | 0.5 | 2.0 | 31.1 | 0.443 |
| 3x95mm2 | SM | 1.6 | 0.5 | 2.2 | 35.4 | 0.320 |
| 3x120mm2 | SM | 1.6 | 0.5 | 2.3 | 38.2 | 0.253 |
| 3x150mm2 | SM | 1.8 | 0.5 | 2.4 | 41.7 | 0.206 |
| 3x185mm2 | SM | 2.0 | 0.5 | 2.6 | 46.0 | 0.164 |
| 3x240mm2 | SM | 2.2 | 0.5 | 2.8 | 51.4 | 0.125 |
| 3x300mm2 | SM | 2.4 | 0.5 | 3.0 | 56.5 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 3+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 3×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 14.9 | 12.1 | 18.1 |
| 3×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 16.7 | 7.41 | 12.1 |
| 3×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 18.2 | 4.61 | 7.41 |
| 3×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 20.8 | 3.08 | 4.61 |
| 3×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 23.5 | 1.91 | 3.08 |
| 3×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 24.2 | 1.20 | 1.91 |
| 3×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 25.9 | 0.868 | 1.91 |
| 3×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.0 | 30.5 | 0.641 | 1.20 |
| 3×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.9 | 0.443 | 0.868 |
| 3×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.3 | 38.5 | 0.320 | 0.641 |
| 3×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 41.8 | 0.253 | 0.443 |
| 3×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.5 | 45.0 | 0.206 | 0.443 |
| 3×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.7 | 49.9 | 0.164 | 0.320 |
| 3×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 2.9 | 55.5 | 0.125 | 0.253 |
| 3×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.1 | 61.0 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, four cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 4×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.2 | 18.1 |
| 4×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.1 | 12.1 |
| 4x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 7.41 |
| 4x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 4.61 |
| 4x10mm2 | RM | 1.0 | 0.2 | 1.8 | 21.6 | 3.08 |
| 4x16mm2 | RM | 1.0 | 0.2 | 1.8 | 24.1 | 1.91 |
| 4x25mm2 | SM | 1.2 | 0.2 | 1.8 | 23.8 | 1.20 |
| 4x35mm2 | SM | 1.2 | 0.2 | 1.8 | 25.9 | 0.868 |
| 4x50mm2 | SM | 1.4 | 0.5 | 2.0 | 31.4 | 0.641 |
| 4x70mm2 | SM | 1.4 | 0.5 | 2.1 | 35.0 | 0.443 |
| 4x95mm2 | SM | 1.6 | 0.5 | 2.3 | 39.9 | 0.320 |
| 4x120mm2 | SM | 1.6 | 0.5 | 2.4 | 43.1 | 0.253 |
| 4x150mm2 | SM | 1.8 | 0.5 | 2.6 | 47.3 | 0.206 |
| 4x185mm2 | SM | 2.0 | 0.5 | 2.8 | 52.3 | 0.164 |
| 4x240mm2 | SM | 2.2 | 0.5 | 3.0 | 58.4 | 0.125 |
| 4x300mm2 | SM | 2.4 | 0.5 | 3.2 | 64.3 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, five cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables , CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 5×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.0 | 18.1 |
| 5×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 16.1 | 12.1 |
| 5x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 7.41 |
| 5x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 19.8 | 4.61 |
| 5x10mm2 | RM | 1.0 | 0.2 | 1.8 | 23.3 | 3.08 |
| 5x16mm2 | RM | 1.0 | 0.2 | 1.8 | 26.2 | 1.91 |
| 5x25mm2 | SM | 1.2 | 0.2 | 1.8 | 26.1 | 1.20 |
| 5x35mm2 | SM | 1.2 | 0.5 | 2.0 | 30.7 | 0.868 |
| 5x50mm2 | SM | 1.4 | 0.5 | 2.1 | 34.6 | 0.641 |
| 5x70mm2 | SM | 1.4 | 0.5 | 2.3 | 38.9 | 0.443 |
| 5x95mm2 | SM | 1.6 | 0.5 | 2.5 | 44.4 | 0.320 |
| 5x120mm2 | SM | 1.6 | 0.5 | 2.6 | 47.9 | 0.253 |
| 5x150mm2 | SM | 1.8 | 0.5 | 2.8 | 52.6 | 0.206 |
| 5x185mm2 | SM | 2.0 | 0.5 | 2.9 | 57.9 | 0.164 |
| 5x240mm2 | SM | 2.2 | 0.5 | 3.2 | 65.0 | 0.125 |
| 5x300mm2 | SM | 2.4 | 0.5 | 3.4 | 71.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 4+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 4×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 15.9 | 12.1 | 18.1 |
| 4×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 18.0 | 7.41 | 12.1 |
| 4×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 19.6 | 4.61 | 7.41 |
| 4×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 22.6 | 3.08 | 4.61 |
| 4×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 25.6 | 1.91 | 3.08 |
| 4×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 26.6 | 1.20 | 1.91 |
| 4×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.9 | 28.7 | 0.868 | 1.91 |
| 4×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.8 | 0.641 | 1.20 |
| 4×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.3 | 37.8 | 0.443 | 0.868 |
| 4×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 42.8 | 0.320 | 0.641 |
| 4×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.6 | 46.6 | 0.253 | 0.443 |
| 4×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.7 | 50.4 | 0.206 | 0.443 |
| 4×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.9 | 55.9 | 0.164 | 0.320 |
| 4×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 3.1 | 62.2 | 0.125 | 0.253 |
| 4×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.3 | 68.4 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
We are China 0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electrical Cable Products
35kv Copper Core XLPE Insulated Power Cable
0.6/1kv 95mm2 XLPE Insulated Armored Power Cable
0.6/1kv XLPE Insulation PVC Sheath Copper Core Power Cable
Electric XLPE Power Cable 11kV PILC Cu 3 Core 120mm2 Armoured Medium Power Cable
Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead Cable for Power Distribution
Popular jytopcable Products
ASTM Standard Triplex Service Drop Overhead Transmision AAC/AAAC/ACSR ABC Aluminum Cable
BVVB Type Flat Twin PVC Cabling Insulation PVC Jacket Cable
Flexible Welding Cable with Rubber Insulation
2.5mm Copper PVC Insulated Electric Building Wire for BS6004, Cenelec HD21.3 Standard
N2xsey 3*240mm2 Copper XLPE Insulation PVC Sheath Copper Wire Screen Power Cable
Flexibile Electric Wire PVC Insulated Electric Wire 2.5sq. mm
Popular PVC Insulated Cable Products
450/750V PVC Insulated Cable Used as Power
PVC Insulated Steel Tape Armored Power Cable
ABC Aerial Cable XLPE/PE Insulated 10mm2 16mm2 35mm2 50mm2 Cable Wire
Medium Voltage XLPE Insulated Steel Wire Armoured Power Cable.
600V 16mm2 Stranded Aluminum Conductor SEU Concentric Neutral Cable
Popular PVC Jacket Cable Products
Five Cores PVC Copper Cable, PVC Jacket Cable Premium Quality 2 Years Warranty
PVC Jacket Flexible Battery Cable, Electrical Wire Cable
H05V-U, H05V-K, H05V-R Single Core Copper Flexible PVC Insulated Jacket Wire and Cable
BVVB Type Flat Twin PVC Cabling Insulation PVC Jacket Cable
Tags: Electrical Cable, jytopcable, PVC Insulated Cable, PVC Jacket Cable