0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable
0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Rated Voltage: 0.6/1kv Conductor material: copper
Insulation material: PVC Sheath Material: PVC
Core: 1,2,3, 4,5, 3+1,3+2,4+1 Certificate: ISO, CCC,BV
Standard: GB/T12706-2002
Trademark: jytop or OEM
Installation temperature: not lower than 0°C
Operating Temperature: 70°C Max
Short-circuit Max. Conductor Temperature: 160°C
Short-circuit Max : 5s
Bending radius: not be less than 15 times of cable outer diameter
Application: Being laid indoors, in tunnels or in ducts, unable to bear mechanical external force.
Technical data of 0.6/1KV, Single core, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 1x10mm2 | RM | 1.0 | 0.2 | 1.8 | 12.9 | 3.08 |
| 1x16mm2 | RM | 1.0 | 0.2 | 1.8 | 13.9 | 1.91 |
| 1x25mm2 | RM | 1.2 | 0.2 | 1.8 | 14.3 | 1.20 |
| 1x35mm2 | RM | 1.2 | 0.2 | 1.8 | 15.5 | 0.868 |
| 1x50mm2 | RM | 1.4 | 0.2 | 1.8 | 17.2 | 0.641 |
| 1x70mm2 | RM | 1.4 | 0.2 | 1.8 | 19.0 | 0.443 |
| 1x95mm2 | RM | 1.6 | 0.2 | 1.8 | 21.3 | 0.320 |
| 1x120mm2 | RM | 1.6 | 0.2 | 1.8 | 22.9 | 0.253 |
| 1x150mm2 | RM | 1.8 | 0.2 | 1.8 | 24.9 | 0.206 |
| 1x185mm2 | RM | 2.0 | 0.2 | 1.8 | 27.1 | 0.164 |
| 1x240mm2 | RM | 2.2 | 0.2 | 1.8 | 30.2 | 0.125 |
| 1x300mm2 | RM | 2.4 | 0.5 | 2.0 | 35.2 | 0.100 |
| 1x400mm2 | RM | 2.6 | 0.5 | 2.1 | 38.8 | 0.0778 |
| 1x500mm2 | RM | 2.8 | 0.5 | 2.2 | 43.0 | 0.0605 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, two cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 2×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 12.9 | 18.1 |
| 2×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.7 | 12.1 |
| 2x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 15.5 | 7.41 |
| 2x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.5 | 4.61 |
| 2x10mm2 | RM | 1.0 | 0.2 | 1.8 | 19.1 | 3.08 |
| 2x16mm2 | RM | 1.0 | 0.2 | 1.8 | 21.2 | 1.91 |
| 2x25mm2 | SM | 1.2 | 0.2 | 1.8 | 18.6 | 1.20 |
| 2x35mm2 | SM | 1.2 | 0.2 | 1.8 | 20.1 | 0.868 |
| 2x50mm2 | SM | 1.4 | 0.2 | 1.8 | 22.4 | 0.641 |
| 2x70mm2 | SM | 1.4 | 0.5 | 2.0 | 26.9 | 0.443 |
| 2x95mm2 | SM | 1.6 | 0.5 | 2.1 | 30.3 | 0.320 |
| 2x120mm2 | SM | 1.6 | 0.5 | 2.2 | 32.6 | 0.253 |
| 2x150mm2 | SM | 1.8 | 0.5 | 2.3 | 35.5 | 0.206 |
| 2x185mm2 | SM | 2.0 | 0.5 | 2.5 | 39.1 | 0.164 |
| 2x240mm2 | SM | 2.2 | 0.5 | 2.7 | 43.6 | 0.125 |
| 2x300mm2 | SM | 2.4 | 0.5 | 2.8 | 47.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, three cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 3×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.4 | 18.1 |
| 3×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.3 | 12.1 |
| 3x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.1 | 7.41 |
| 3x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 4.61 |
| 3x10mm2 | RM | 1.0 | 0.2 | 1.8 | 20.0 | 3.08 |
| 3x16mm2 | RM | 1.0 | 0.2 | 1.8 | 22.3 | 1.91 |
| 3x25mm2 | SM | 1.2 | 0.2 | 1.8 | 21.3 | 1.20 |
| 3x35mm2 | SM | 1.2 | 0.2 | 1.8 | 23.2 | 0.868 |
| 3x50mm2 | SM | 1.4 | 0.2 | 1.9 | 26.2 | 0.641 |
| 3x70mm2 | SM | 1.4 | 0.5 | 2.0 | 31.1 | 0.443 |
| 3x95mm2 | SM | 1.6 | 0.5 | 2.2 | 35.4 | 0.320 |
| 3x120mm2 | SM | 1.6 | 0.5 | 2.3 | 38.2 | 0.253 |
| 3x150mm2 | SM | 1.8 | 0.5 | 2.4 | 41.7 | 0.206 |
| 3x185mm2 | SM | 2.0 | 0.5 | 2.6 | 46.0 | 0.164 |
| 3x240mm2 | SM | 2.2 | 0.5 | 2.8 | 51.4 | 0.125 |
| 3x300mm2 | SM | 2.4 | 0.5 | 3.0 | 56.5 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 3+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 3×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 14.9 | 12.1 | 18.1 |
| 3×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 16.7 | 7.41 | 12.1 |
| 3×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 18.2 | 4.61 | 7.41 |
| 3×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 20.8 | 3.08 | 4.61 |
| 3×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 23.5 | 1.91 | 3.08 |
| 3×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 24.2 | 1.20 | 1.91 |
| 3×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 25.9 | 0.868 | 1.91 |
| 3×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.0 | 30.5 | 0.641 | 1.20 |
| 3×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.9 | 0.443 | 0.868 |
| 3×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.3 | 38.5 | 0.320 | 0.641 |
| 3×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 41.8 | 0.253 | 0.443 |
| 3×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.5 | 45.0 | 0.206 | 0.443 |
| 3×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.7 | 49.9 | 0.164 | 0.320 |
| 3×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 2.9 | 55.5 | 0.125 | 0.253 |
| 3×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.1 | 61.0 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, four cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 4×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.2 | 18.1 |
| 4×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.1 | 12.1 |
| 4x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 7.41 |
| 4x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 4.61 |
| 4x10mm2 | RM | 1.0 | 0.2 | 1.8 | 21.6 | 3.08 |
| 4x16mm2 | RM | 1.0 | 0.2 | 1.8 | 24.1 | 1.91 |
| 4x25mm2 | SM | 1.2 | 0.2 | 1.8 | 23.8 | 1.20 |
| 4x35mm2 | SM | 1.2 | 0.2 | 1.8 | 25.9 | 0.868 |
| 4x50mm2 | SM | 1.4 | 0.5 | 2.0 | 31.4 | 0.641 |
| 4x70mm2 | SM | 1.4 | 0.5 | 2.1 | 35.0 | 0.443 |
| 4x95mm2 | SM | 1.6 | 0.5 | 2.3 | 39.9 | 0.320 |
| 4x120mm2 | SM | 1.6 | 0.5 | 2.4 | 43.1 | 0.253 |
| 4x150mm2 | SM | 1.8 | 0.5 | 2.6 | 47.3 | 0.206 |
| 4x185mm2 | SM | 2.0 | 0.5 | 2.8 | 52.3 | 0.164 |
| 4x240mm2 | SM | 2.2 | 0.5 | 3.0 | 58.4 | 0.125 |
| 4x300mm2 | SM | 2.4 | 0.5 | 3.2 | 64.3 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, five cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables , CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 5×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.0 | 18.1 |
| 5×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 16.1 | 12.1 |
| 5x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 7.41 |
| 5x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 19.8 | 4.61 |
| 5x10mm2 | RM | 1.0 | 0.2 | 1.8 | 23.3 | 3.08 |
| 5x16mm2 | RM | 1.0 | 0.2 | 1.8 | 26.2 | 1.91 |
| 5x25mm2 | SM | 1.2 | 0.2 | 1.8 | 26.1 | 1.20 |
| 5x35mm2 | SM | 1.2 | 0.5 | 2.0 | 30.7 | 0.868 |
| 5x50mm2 | SM | 1.4 | 0.5 | 2.1 | 34.6 | 0.641 |
| 5x70mm2 | SM | 1.4 | 0.5 | 2.3 | 38.9 | 0.443 |
| 5x95mm2 | SM | 1.6 | 0.5 | 2.5 | 44.4 | 0.320 |
| 5x120mm2 | SM | 1.6 | 0.5 | 2.6 | 47.9 | 0.253 |
| 5x150mm2 | SM | 1.8 | 0.5 | 2.8 | 52.6 | 0.206 |
| 5x185mm2 | SM | 2.0 | 0.5 | 2.9 | 57.9 | 0.164 |
| 5x240mm2 | SM | 2.2 | 0.5 | 3.2 | 65.0 | 0.125 |
| 5x300mm2 | SM | 2.4 | 0.5 | 3.4 | 71.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 4+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 4×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 15.9 | 12.1 | 18.1 |
| 4×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 18.0 | 7.41 | 12.1 |
| 4×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 19.6 | 4.61 | 7.41 |
| 4×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 22.6 | 3.08 | 4.61 |
| 4×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 25.6 | 1.91 | 3.08 |
| 4×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 26.6 | 1.20 | 1.91 |
| 4×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.9 | 28.7 | 0.868 | 1.91 |
| 4×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.8 | 0.641 | 1.20 |
| 4×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.3 | 37.8 | 0.443 | 0.868 |
| 4×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 42.8 | 0.320 | 0.641 |
| 4×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.6 | 46.6 | 0.253 | 0.443 |
| 4×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.7 | 50.4 | 0.206 | 0.443 |
| 4×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.9 | 55.9 | 0.164 | 0.320 |
| 4×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 3.1 | 62.2 | 0.125 | 0.253 |
| 4×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.3 | 68.4 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
We are China 0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electrical Cable Products
N2xsey, Power Cable, 12/20 Kv, 3/C, Cu/XLPE/Cws/PVC (DIN VDE 0276-620)
Hot Selling High Electrical Voltage XLPE Power Cable
High Quality XLPE Insulated Power Cable Manufacturer (CU/XLPE/PVC)
Multicore Copper Conductor Kvv Flexible Control Electric Cable
0.75mm Stranded Red BV Wire Cable with ISO
Popular jytopcable Products
Bare Conductor ACSR/Aw Aluminum Conductor Steel Reinforced to ASTM Standard
Earth Wire Yellow/Green Wire PVC Insulated Wire
0.6/1kv Self Suppor Caai Cable, Caai-S Cable
300/500V Low Smoke Halogen Free Flame Retardant Steel Wire Armoured Ground Cable
Copper Conductor XLPE Insulated Power Cable for Middle Voltage 12/20kv
Popular PVC Insulated Cable Products
Copper Conductor Cable 4 Core PVC Power Cable
PVC Insulated and PVC Sheated Wire or Cable
600 / 1000V Aluminum Conductor PVC Insulated PVC Sheathed Electrical Power Cable
PVC Insulated and Sheathed Control Cable
Electrical Cable Mv 0.6/1kv PVC Insulated Power Cable VV Vlv Vy Vly.
H07V-K PVC Insulated Installation Flexible Cable and Wires
Popular PVC Jacket Cable Products
PVC Jacket Flexible Battery Cable, Electrical Wire Cable
BVVB Type Flat Twin PVC Cabling Insulation PVC Jacket Cable
H05V-U, H05V-K, H05V-R Single Core Copper Flexible PVC Insulated Jacket Wire and Cable
Five Cores PVC Copper Cable, PVC Jacket Cable Premium Quality 2 Years Warranty
Tags: Electrical Cable, jytopcable, PVC Insulated Cable, PVC Jacket Cable