0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv
0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv image
Get Latest Price Request a quote
Quick Details
Product Details
For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.
Standards
IEC 60502, IEC 60228
Products Type
Type | Descriptions | Applications |
CVV | Copper conductor PVC insulated PVC sheathed control cables | For laying indoor, in tunnels, ducts, conduit etc.permanent place |
NOTE: Henan Hongda can produce "Flame-Retardant Series", "Fire-Resistant Series", "Low Smoke Halogen Free (LSHF/LSOH) Series","Low Smoke Low Halogen (LSLH) Series", etc. control cable as customer required.
Performance in line with IEC60332: 2004 requirements.
Construction
Conductor: Concentric Stranded copper wire
Insulation: PVC Black color
Identification : Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath : PVC Black color
2 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
2 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 98 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.0 | 24.5 | 0.0142 | 110 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 10.5 | 18.1 | 0.0135 | 115 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.0 | 12.1 | 0.0115 | 135 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 12.0 | 7.41 | 0.0093 | 180 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 14.5 | 4.61 | 0.0092 | 255 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 15.5 | 3.08 | 0.0078 | 320 | 500/D |
3 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
5 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
9 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
11 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
11 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 255 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 315 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 340 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 425 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 605 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 915 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1220 | 500/D |
12 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
12 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 265 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 320 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 345 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 440 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 630 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 950 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1270 | 500/D |
13 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
13 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 295 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 355 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 380 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 485 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 695 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1050 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1405 | 500/D |
14 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
14 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 300 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 360 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 390 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 495 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 715 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1085 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1455 | 500/D |
15 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
15 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 395 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 425 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 545 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 785 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1195 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1600 | 500/D |
16 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
16 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 400 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 435 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 555 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 805 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1230 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1650 | 500/D |
17 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
17 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 355 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 430 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 465 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 595 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 865 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1785 | 500/D |
18 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
18 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 360 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 435 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 475 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 605 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 885 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1350 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1835 | 500/D |
19 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
19 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 365 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 445 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 480 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 620 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 905 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1385 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1885 | 500/D |
20 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
20 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 390 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 475 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 515 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 665 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 975 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1490 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
21 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
21 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 400 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 490 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 530 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 685 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 1005 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1540 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
22 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
22 | 0.5 | 7/0.30 | 0.8 | 1.8 | 20.0 | 36.0 | 0.0162 | 430 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 520 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 565 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 730 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 265 | 7.41 | 0.0093 | 1070 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1655 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2245 | 500/D |
23 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
23 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.5 | 36.0 | 0.0162 | 440 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 540 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 585 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 755 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 26.5 | 7.41 | 0.0093 | 1105 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1710 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
24 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
24 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 460 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.0 | 24.5 | 0.0142 | 560 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 605 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 24.5 | 12.1 | 0.0115 | 785 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.0 | 7.41 | 0.0093 | 1150 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 34.5 | 4.61 | 0.0092 | 1795 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
25 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
25 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 490 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 595 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 645 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 835 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1225 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1915 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2595 | 500/D |
26 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
27 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
28 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
28 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 535 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 650 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 710 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 915 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1350 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2110 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2885 | 500/D |
29 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
29 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 660 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 715 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 930 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1370 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2145 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2940 | 500/D |
30 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
30 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.0 | 24.5 | 0.0142 | 665 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 725 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 940 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1395 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2180 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2990 | 500/D |
The table of 0.6/1 KV CVV shown concentric stranded conductor only. If you want to have solid or flexible conductor type, please contact with our Sales Department.
Packing & Shipping
We provide you with the best product packaging design services, thereby allowing you to save more shipping charges.
FAQ
1. Q: Are you the factory or the trading company?
A: We are the factory.
2. Q: How long is your guarantee Period?
A: We usually offer 1 year guarantee for our general products.
3. Q: How can I get the samples?
A: We can make the sample order. And usually you will charge for it.
But the samples fee will be return to you when you make the bulk order.
4. Q: Where is your factory? How can we visit your factory?
A: Our factory located in Jiaozuo city, Henan Province and our office is in Zhengzhou city. You could reach here by train and by air. We can pick you up in the airport and the railway station.
5. Q: What is your MOQ?
A: It`s base on the cable type or size. Please contact Ms. Melon. She will offer you the details.
Factory
Established in 2004, Henan Hongda Cable Co., Ltd, is dedicated into manufacturing various types of electric power wire and cable. Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.
Today, Henan Hongda has grown into an integrated system solution provider in electric power distribution industry, extending the business from power cable and electric wire manufacture to electric power distribution system design, and electric distribution system construction and installation.
Our Service
1. Design wire and cable according to your real application
2. Optimized reel size for freight cost saving
3. Customized package to feature your brand
4. Short lead time to meet your urgent demand
5. Diversified delivery terms for your options
6. Quick response (24 hours on line)
7. Professional knowledge for clear answer to your any question
8. Comprehensive technical documents to support your tender bidding
9. One-year limited warranty for our wire and cable
10. Cable sample available
11. Specify the cable only according to the location
12. OEM is available
13. Abundant cables and wires for your option
Contact Us
Ms. Melon Liu
************************************************************************************************
Tel: +86 371 55668386 / 55568559 Fax: +86371 6097 5616
Mob. : +86 139 3900 7360
Henan Hongda Cable Co., Ltd http://zzhongdacable.en.
Changping Road 3,Zhandian NewDistrict,Wuzhi County,Jiaozuo,Henan Province, China
Office Add: Room2108,Yaxing Times Square,Zhengzhou,Henan,China. P.C. 450000
************************************************************************************************
We are China 0.6/1kv IEC 60502 2-30 Core Cu/PVC/PVC Flame Retardant Control Cable Cvv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Control Cable Cvv Products
Popular Cvv Products
Flexible Copper Electric Wire 7 Core PVC Cvv Cable 1.5mm2
Popular Cvv Cable Products
Cvv 20X2.5mm2 Control Cable Flexible Copper Wire PVC Insulated Sheathed
Multicore Stranded Copper PVC Sheath 4 Core 25mm2 Cvv Power Control Cable
The Multi-Core Coloured Soft Control Cable Vct-F Cvvs Cvv Cable
0, 6/1kv 4 Cores Copper Conductor XLPE Insulation PVC Sheath Cvv Cxv Cxe Cx Cable
0, 6/1kv 3 Core 4 Cores Copper Conductor XLPE Insulation PVC Sheath Cvv Cxv Cxe Cx Cable
600V PVC Insulated and Sheathed Copper Conductor Control Cable Cvv
Popular zzhongdacable Products
4*1.5mm2 Copper Insulated Power Cable 0.6/1 Kv Copper Cable
1kv Power Cable Zr Yjv Yjv22 XLPE Power Cable
Cable De Alambre AWG 12 10 8 6 4 Electric Wire PVC Insulation
600 / 1000 V Aluminum Cable Wire Amka Aerial Cable 3 X 16 + 25mm
Good Price ACSR Cable Supplied by Cable Manufacture
4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable
Tags: Control Cable Cvv, Cvv, Cvv Cable, zzhongdacable