0.6/1kv Low Voltage Overhead ABC Aerial Bundle Cable Manufacturer

China 
                        0.6/1kv Low Voltage Overhead ABC Aerial Bundle Cable Manufacturer
                      manufacture and supplier

0.6/1kv Low Voltage Overhead ABC Aerial Bundle Cable Manufacturer image

Get Latest Price Request a quote

Quick Details

0.6/1kv Low Voltage Overhead ABC Aerial Bundle Cable Manufacturer

overhard bundle cable

Jytop

ISO9001, CE, CCC

Overhead Transmission Line

Round Wire

PVC or XLPE

No

Aluminum or Aluminum Alloy or Aluminum & Steel

Overhead

Solid or Stranded

Phase Insulated with Bare Neutral

Black,Red,Yellow,Blue,Brown,Green

16mm 25mm 35mm

0.6/1kv

1,2,3,4 Core

Aluminum or Aluminum Alloy or ACSR

Henan

JYTOP

Packed in Reels

as per IEC, ASTM, BS, Sans

Zhengzhou, China

8544492100

Product Details

0.6/1kv Low Voltage Overhead  ABC Aerial Bundle Cable Manufacturer

We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.

Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1

Table 01 

Type of conductor or core Norminal cross-sectional area mm2 Nubmer of wires
Min.
Diameter of conductormm Resistanceat 20ºC  Ω/km Max.  Breaking force(N) Thickness of insulation (mm) Outer diameter of core(mm)
Min. Max. Min. Average Min. Min. Max.
Phase or auxiliary or non-strain-bearing netural(aluminium) +16 6 4.6 5.1 1.91 2070 1.2 0.98 7.0 7.8
25 6 5.8 6.3 1.2 3300 1.4 1.16 8.6 9.4
35 6 6.8 7.3 0.868 4500 1.6 1.34 10.0 10.9
50 6 7.9 8.4 0.641 6200 1.6 1.34 11.1 12.0
70 12 9.7 10.2 0.443 8900 1.8 1.52 13.3 14.2
95 15 11.0 12.0 0.320 12300 1.8 1.52 14.6 16.0
120 15 12.5 13.5 0.253 15600 1.8 1.52 16.3 17.5
150 15 13.9 15.0 0.206 19200 1.8 1.52 17.1 18.6
Service connection(aluminium) 16 6 4.6 5.2 1.91 2070 1.2 0.98 7.0 8.0
25 6 5.6 6.5 1.2 3300 1.4 1.16 8.6 9.6
Service connection(copper) 10 6 4.2 1.83 3600 1.2 0.98 6.2 7.0
16 6 5.3 1.15 5760 1.2 0.98 7.2 8.0
25 6 6.6 0.727 8750 1.4 1.16 8.6 9.6
    Number and nominal diameter of wires 
mm
               
Supporting 
core(aluminium alloy)
54.6 7×3.15 9.2 9.6 0.630 16600 1.6 1.34 12.3 13.0
70 7×3.50 10.0 10.4 0.500 20100 1.6 1.34 12.9 13.6
+Auxiliary conductors or cores only

When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:

Table 02

1 2
Nominal cross sectional area of supporting conductor mm2 Nominal cross-sectional areas of phase conductors mm2
54.6 25,35,50,70,95
70 70,95,120
95 95,120,150

Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)

Table 03
 

Type of conductor or core Norminal cross-sectional area mm2 Nubmer of wires Diameter of conductormm Resistanceat 20ºC  Ω/km Max.  Breaking force(N) Thickness of insulation (mm) Outer diameter of core(mm)
Min. Max. Min. Average Min. Min. Max.
Phase or auxiliary or non-strain-bearing netural(aluminium) 16 7/1.65 4.6 5.1 1.91 2070 1.2 0.98 7.0 7.8
25 7/2.15 5.8 6.3 1.2 3300 1.4 1.16 8.6 9.4
35 7/2.55 6.8 7.3 0.868 4500 1.6 1.34 10.0 10.9
50 7/2.99 7.9 8.4 0.641 6200 1.6 1.34 11.1 12.0
70 14/2.59 9.7 10.2 0.443 8900 1.8 1.52 13.3 14.2
95 19/2.59 11.0 12.0 0.320 12300 1.8 1.52 14.6 16.0
120 19/2.99 12.5 13.5 0.253 15600 1.8 1.52 16.3 17.5
150 30/2.59 13.9 15.0 0.206 19200 1.8 1.52 17.1 18.6
Service connection(aluminium) 16 7/1.65 4.6 5.2 1.91 2070 1.2 0.98 7.0 8.0
25 7/2.15 5.6 6.5 1.2 3300 1.4 1.16 8.6 9.6
Service connection(copper) 10 7/1.35 4.2 1.83 3600 1.2 0.98 6.2 7.0
16 7/1.69 5.3 1.15 5760 1.2 0.98 7.2 8.0
25 7/2.19 6.6 0.727 8750 1.4 1.16 8.6 9.6
Supporting core(aluminium alloy) 16 7/1.71 5.1 5.2 2.053 5070 1.4 1.16 7.9 8.0
25 7/2.15 6.4 6.5 1.314 8000 1.4 1.16 9.2 9.3
35 7/2.48 6.6 7.5 0.986 10300 1.6 1.34 10.7 10.8
50 7/2.89 7.7 8.4 0.720 14200 1.6 1.34 11.9 12.0
54.6 7/3.15 9.2 9.6 0.630 16600 1.6 1.34 12.3 13.0
70 7/3.50 10.0 10.4 0.500 20100 1.6 1.34 12.9 13.6
 

Why Choose us?  
For over 20 years, Zhengzhou Jinyuan Wire and Cable Co., Ltd., as a professional cable manufacturer has been producing customized cable for a wide range of applications based on high quality, excellent service and competitive market prices. This is an elite team with experienced personnel and strong technical support. Our achievements benefit by having access to the largest market for cheap labor and abundant resources in China and our determination to exceed our clients’ expectations.
 
PRODUCTS & STANDARDS
We can produce more than 2,000 types of cables and wires, such as
Bare Conductor: AAC, AAAC, ACSR, ACSR/AW, ACAR, ACSS, ACSS/AW, Aluminum Clad Steel Wire/Strand, Bare Copper Conductors, Copper Clad Steel Wire/Strand, Copper Clad Aluminum(CCA), Galvanized Steel Wire/Strand, etc.
Overhead Insulated Cable: Covered Line Single Core Cable and Aerial Bundled Cable (ABC). ABC includes Duplex, Triplex, Quadruplex and more Cores Service Drop Cable.
PVC Insulated Wire up to 450/750V
PVC or XLPE Insulated Power Cable from 1kV to 36kV
Control Cable
Welding Cable
Rubber Cable
We can produce cables according to the standards of IEC, ASTM, EN (BS, DIN, NF, etc.), AS/NZ and meet customers’ special requirements.
 
ACHIEVEMENTS & COMMITMENT
Our cable has been exported to South-East Asia, South Asia, Middle-East, Europe, North and South America, Africa, Australia & New Zealand and so on. Zhengzhou Jinyuan Wire and Cable Co., Ltd.’s commitment is to be recognized as a zero-defect world class manufacturer in cable industry through continuous improvement of our quality, processes, and products, and by our determination to exceed our clients’ expectations.

We are China 0.6/1kv Low Voltage Overhead ABC Aerial Bundle Cable Manufacturer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

Hv ABC Cable, Aerial Bundled Cable, Al/XLPE+AAAC, 3/C+1/C, 12.7/22 Kv (AS/NZS 3599.2)

Triplex Service Drop ACSR Neutral Conductor Sanddollar ABC Overhead Drop Cable

HDPE XLPE Insulation 95mm AAC AAAC ABC Cable

Aerial Bundled Cable Duplex Triplex Quadruplex Service Drop XLPE Insulation ABC Cable

Hot Sale Plastic PA1500 Anchoring Clamp for ABC Cable

Low Voltage Service Drop Aerial Boundle ABC Cable

Popular Aerial Bundle Cable Products

0.6/1kv XLPE Insulated Overhead ABC Cable

ASTM Standard XLPE Covered Line ABC Cable

Duplex Service Drop, ACSR Neutral, 1/0AWG Heeler

ABC ABC XLPE Covered Conductor Cable 0.6/1kv Overhead Cable Aerial Bundle Conductor

Aluminum XLPE Insulated Aerial Bundle Conductos ABC

ABC, Distribution System Overhead Cable (1000V)

Popular jytopcable Products

Mv 20kv Aluminum Conductor XLPE Insulated and PVC Sheathed Power Cable

Galvanized Steel Wire/Stay Wire/Guy Wire BS 183 7/4.0mm

1kv PVC Insulated Steel Tape Armored Control Cable Low Voltage LV Armored Control Cable

ASTM Standard Triplex Service Drop Overhead Transmision AAC/AAAC/ACSR ABC Aluminum Cable

ASTM B232/B 232m-99 Sca/ACSR Overhead Aluminum Conductor

Rvvp 300/300V PVC Insulated PVC Sheathed Screen Flexible Control Cable

Popular Overhead Cable Products

AS/NZS Standard Aluminum XLPE Insulation Twisted Overhead ABC Cable 4*50mm2

3X95 mm2 Mv Aerial Bundled Conductor ABC Overhead Cables

Overhead Transmission Line 240/40 GB Standard Aluminum Conductor Steel Reinforced ACSR

Aluminium Conductor Steel Reinforced (ACSR) Overhead Power Cable

2*16 IEC Standard UV-XLPE Insulated Aerial Bundle ABC Cable

Quadruplex Service Drop Aluminum Conductors AAAC 6201 Alloy Neutral-Messenger Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION