0.6/1kv LV 2*150mm2 Aerial Bundled Conductor (ABC) Cables
0.6/1kv LV 2*150mm2 Aerial Bundled Conductor (ABC) Cables image
Get Latest Price Request a quote
- Overview
- Product Description
- Certificates
- Packing
- International Fairs
Basic Info.
Product Description
Aerial Bundled Cables
Aluminium Conductor Cables
LV Aerial Bundled Conductor (ABC) Cables
Application
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the
conventional bare conductor overhead distribution system. It provides higher level of safety and reliability, lower
power losses and ultimate system economy by reducing installation, maintenance and operative cost.
Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at
construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or
street lighting. This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II
acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards
Construction
Conductor: Aluminium conductor, round stranded compressed (RM).
Insulation: XPLE compound, UV-resistant.
Core Identification: 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral
core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50
mm². In the case of five core bundles the surface of the protective core should be smooth.
Electrical Properties
Rated Voltage | 0.6/1kV |
Test Voltage | 4 Veff kV |
Minimum Laying Temperature | -20°C |
Operating Temperature | -40°C~ +90°C |
Maximum Short-circuit Temperature | 250°C |
Maximum Conductor Temperature | 80°C |
Minimum Bending Radius | 18×OD |
Construction Parameters BS 7870
Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
1×16 RM | 8.0 | 74 | 1.910 | 2.5 | 72 |
1×25 RM | 9.0 | 106 | 1.200 | 4.0 | 107 |
1×35 RM | 10.5 | 138 | 0.868 | 5.5 | 132 |
1×50 RM | 11.8 | 182 | 0.641 | 8.0 | 165 |
1×70 RM | 13.0 | 252 | 0.443 | 10.7 | 205 |
1×95 RM | 15.4 | 333 | 0.320 | 13.7 | 240 |
1×120 RM | 17.0 | 408 | 0.253 | 18.6 | 290 |
1×150 RM | 19.0 | 502 | 0.206 | 23.2 | 334 |
1×185 RM | 21.0 | 611 | 0.164 | 28.7 | 389 |
1×240 RM | 24.0 | 801 | 0.125 | 37.2 | 467 |
2×16 RM | 15.6 | 147 | 1.910 | 2.5 | 72 |
2×25 RM | 18.0 | 208 | 1.200 | 4.0 | 107 |
2×35 RM | 20.0 | 277 | 0.868 | 5.5 | 132 |
2×50 RM | 23.5 | 361 | 0.641 | 8.0 | 165 |
2×70 RM | 25.4 | 505 | 0.443 | 10.7 | 205 |
2×95 RM | 30.3 | 666 | 0.320 | 13.7 | 240 |
2×150 RM | 38.0 | 1004 | 0.206 | 23.2 | 334 |
4×16 RM | 18.8 | 286 | 1.910 | 2.5 | 72 |
4×25 RM | 21.2 | 430 | 1.200 | 4.0 | 107 |
4×35 RM | 24.1 | 553 | 0.868 | 5.5 | 132 |
4×50 RM | 27.8 | 746 | 0.641 | 8.0 | 165 |
4×70 RM | 31.8 | 1009 | 0.443 | 10.7 | 205 |
4×95 RM | 37.8 | 1332 | 0.320 | 13.7 | 240 |
4×120 RM | 54.4 | 1632 | 0.253 | 18.6 | 290 |
4×50 + 1×25 RM | 31.9 | 814 | 0.641/1.200 | 8.0/4.0 | 165/107 |
4×50 + 1×35 RM | 31.9 | 845 | 0.641/0.868 | 8.5/5.5 | 165/132 |
4×70 + 1×25 RM | 36.0 | 1105 | 0.443/1.200 | 10.7/4.0 | 205/107 |
4×70 + 2×25 RM | 40.0 | 1217 | 0.443/1.200 | 10.7/4.0 | 205/107 |
4×95 + 1×25 RM | 41.8 | 1438 | 0.320/1.200 | 13.7/4.0 | 240/107 |
4×95 + 2×25 RM | 42.0 | 1544 | 0.320/1.200 | 13.7/4.0 | 240/107 |
4×120 + 1×25 RM | 59.0 | 2050 | 0.253/1.200 | 18.6/4.0 | 290/107 |
Other cross-sections can be offered upon request. TNB Specification(IEC 60502)
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
1×16+1×25 RM | 15.3 | 160 | 1.910 | 2.5 | 72 |
3×16+1×25 RM | 19.0 | 290 | 1.200 | 4.0 | 107 |
3×25+1×25 RM | 23.2 | 400 | 0.868 | 5.5 | 132 |
3×35+1×25 RM | 25.6 | 500 | 0.641 | 8.0 | 165 |
3×50+1×35 RM | 30.0 | 680 | 0.443 | 10.7 | 205 |
3×70+1×50 RM | 34.9 | 920 | 0.320 | 13.7 | 240 |
3×95+1×70 RM | 40.6 | 1270 | 0.253 | 18.6 | 290 |
3×120+1×70 RM | 44.1 | 1510 | 0.206 | 23.2 | 334 |
3×150+1×95 RM | 49.2 | 1870 | 0.164 | 28.7 | 389 |
3×185+1×120 RM | 54.9 | 2340 | 0.125 | 37.2 | 467 |
3×25+1×25+1×16 RM | 23.2 | 470 | 1.910 | 2.5 | 72 |
3×35+1×25+1×16 RM | 25.6 | 560 | 1.200 | 4.0 | 107 |
3×50+1×35+1×16 RM | 30.0 | 740 | 0.868 | 5.5 | 132 |
3×70+1×50+1×16 RM | 34.9 | 980 | 0.641 | 8.0 | 165 |
3×95+1×70+1×16 RM | 40.6 | 1330 | 0.443 | 10.7 | 205 |
3×120+1×70+1×16 RM | 44.1 | 1580 | 0.320 | 13.7 | 240 |
3×150+1×95+1×16 RM | 49.2 | 1940 | 0.206 | 23.2 | 334 |
3×185+1×120+1×16 RM | 54.9 | 2410 | 1.910 | 2.5 | 72 |
Other cross-sections can be offered upon request. HD 626 S1
Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | KN | A |
2×16 RM | 72 | 147 | 1.910 | 2.5 |
2×25 RM | 107 | 208 | 1.200 | 4.0 |
2×35 RM | 132 | 277 | 0.868 | 5.5 |
2×50 RM | 165 | 361 | 0.641 | 8.0 |
4×16 RM | 72 | 286 | 1.910 | 2.5 |
4×25 RM | 107 | 430 | 1.200 | 4.0 |
4×35 RM | 132 | 553 | 0.868 | 5.5 |
4×50 RM | 165 | 746 | 0.641 | 8.0 |
4×70 RM | 205 | 1009 | 0.443 | 10.7 |
4×95 RM | 240 | 1332 | 0.320 | 13.7 |
4×120 RM | 290 | 1632 | 0.253 | 18.6 |
4×35 + 1×35 RM | 132/132 | 694 | 0.868/0.868 | 5.5/5.5 |
4×50 + 1×25 RM | 165/107 | 814 | 0.641/1.200 | 8.0/4.0 |
4×50 + 1×35 RM | 165/132 | 845 | 0.641/0.868 | 8.5/5.5 |
4×70 + 1×25 RM | 205/107 | 1105 | 0.443/1.200 | 10.7/4.0 |
4×70 + 2×25 RM | 205/107 | 1217 | 0.443/1.200 | 10.7/4.0 |
4×70 + 1×35 RM | 205/132 | 1150 | 0.443/0.868 | 10.7/5.5 |
4×70 + 2×35 RM | 205/132 | 1289 | 0.443/0.868 | 10.7/5.5 |
4×95 + 1×25 RM | 240/107 | 1438 | 0.320/1.200 | 13.7/4.0 |
4×95 + 1×35 RM | 240/132 | 1467 | 0.320/0.868 | 13.7/5.5 |
4×95 + 2×25 RM | 240/107 | 1544 | 0.320/1.200 | 13.7/4.0 |
Other cross-sections can be offered upon request. NFC 33-209
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
2×10 RM | 12.8 | 93 | 3.080 | 1.5 | 38 |
4×10 RM | 15.4 | 183 | 3.080 | 1.5 | 38 |
2×16 RM | 14.8 | 129 | 1.910 | 2.3 | 72 |
2×16 RN + 2×1.5 RE | 14.8 | 176 | 1.910/12.100 | 2.3 | 72 |
4×16 RM | 17.8 | 257 | 1.910 | 2.3 | 72 |
4×16 RN + 2×1.5 RE | 17.8 | 304 | 1.910/12.100 | 2.3 | 72 |
2×25 RM | 18.0 | 202 | 1.200 | 3.8 | 107 |
2×25 RM + 2×1.5 RE | 18.0 | 249 | 1.200/12.100 | 3.8 | 107 |
4×25 RM | 21.7 | 404 | 1.200 | 3.8 | 107 |
4×25 RM + 2×1.5 RE | 21.7 | 451 | 1.200/12.100 | 3.8 | 107 |
2×35 RM | 20.8 | 269 | 0.868 | 5.2 | 132 |
2×35 RM + 2×1.5 RE | 20.8 | 316 | 0.868/12.100 | 5.2 | 132 |
4×35 RM | 25.1 | 539 | 0.868 | 5.2 | 132 |
4×35 RM + 2×1.5 RE | 25.1 | 586 | 0.868/12.100 | 5.2 | 132 |
2×50 RM | 23.4 | 352 | 0.641 | 7.6 | 165 |
2×50 RM + 2×1.5 RE | 23.4 | 399 | 0.641/12.100 | 7.6 | 165 |
1×54.6 RM + 3×25 RM | 21.7 | 507 | 0.630/1.200 | 3.8 | 107 |
1×54.6 RM + 3×25 RM + 1×16 RM | 24.3 | 573 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 2×16 RM | 29.7 | 639 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 3×16 RM | 31.1 | 705 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×35 RM | 25.1 | 615 | 0.630/0.868 | 5.2 | 132 |
1×54.6 RM + 3×35 RM + 1×16 RM | 28.1 | 680 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 2×16 RM | 34.3 | 748 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 3×16 RM | 35.9 | 814 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 1×25 RM | 28.1 | 714 | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 |
1×54.6 RM + 3×50 RM | 28.2 | 741 | 0.630/0.641 | 7.6 | 165 |
1×54.6 RM + 3×50 RM + 1×16 RM | 31.6 | 806 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 2×16 RM | 38.6 | 875 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 3×16 RM | 40.4 | 940 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 1×25 RM | 31.6 | 841 | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 |
1×54.6 RM + 3×70 RM | 33.0 | 950 | 0.630/0.443 | 10.2 | 205 |
1×54.6 RM + 3×70 RM + 1×16 RM | 37.0 | 1014 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 2×16 RM | 45.2 | 1083 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 3×16 RM | 47.3 | 1148 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 1×25 RM | 37.0 | 1048 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 2×25 RM | 45.2 | 1150 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 3×25 RM | 47.3 | 1250 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×95 RM | 37.4 | 1176 | 0.630/0.320 | 13.5 | 240 |
1×54.6 RM + 3×95 RM + 1×16 RM | 41.9 | 1243 | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 |
Other cross-sections can be offered upon request. AS/NZS 3560 Part 1
Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Minimum Breaking Load | Current Rating |
No.×mm² | mm | Kg/Km | KN | A |
2×16 RM | 15.0 | 140 | 4.4 | 78 |
2×25 RM | 17.6 | 210 | 7.0 | 105 |
2×35 RM | 19.6 | 270 | 9.8 | 125 |
2×50 RM | 22.8 | 370 | 11.4 | 150 |
2×95 RM | 30.6 | 680 | 15.3 | 230 |
3×25 RM | 19.0 | 310 | 8.8 | 97 |
3×35 RM | 21.1 | 410 | 9.8 | 120 |
3×50 RM | 24.6 | 550 | 11.4 | 140 |
4×16 RM | 18.1 | 290 | 8.8 | 74 |
4×25 RM | 21.2 | 410 | 14.0 | 97 |
4×35 RM | 23.7 | 550 | 19.6 | 120 |
4×50 RM | 27.5 | 740 | 28.0 | 140 |
4×70 RM | 31.9 | 1000 | 39.2 | 175 |
4×95 RM | 36.9 | 1370 | 53.2 | 215 |
4×120 RM | 40.6 | 1690 | 67.2 | 250 |
4×150 RM | 43.9 | 2020 | 84.0 | 280 |
Other cross-sections can be offered upon request.
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China 0.6/1kv LV 2*150mm2 Aerial Bundled Conductor (ABC) Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6/1kv LV 2*150mm2 Aerial Bundled Conductor (ABC) Cables Products
Popular 1X240mm2 ABC Cable Products
0.6/1kv Cyclops 2*2/0AWG+2/0AWG Triplex Service Drop ABC Cable
Purpura 2*1/0AWG+1/0AWG Triplex Service Drop ABC Cable
2*16+16 LV NFC 33-209 Aerial Bunched ABC Cable
1*1X240mm2 ABC Cable Triplex ABC Cable Aerial Bundle Cable
0.6/1kv Minex 2*6AWG+6AWG Triplex Service Drop ABC Cable
ABC Cable Size16sqmm/25sqmm/50sqmm/70sqmm/95sqmm
Popular Aluminum ABC Cable Products
0.6/1kv 1*240mm2 LV BS 7870 Aerial Bundled Conductor (ABC) Cables
4 Cores 3*1+1AWG Quadruplex Aluminum Overhead ABC Cable with Phase and Neutral Conductor
0. /1kv XLPE/PE Insulation Twisted 2*1/0 AWG Duplex Aluminum ABC Cable
1*25+25 LV NFC 33-209 Aerial Bunched ABC Cable
Quince 1/0AWG Covered Line Wire
0.6/1kv Cyclops 2*2/0AWG+2/0AWG Triplex Service Drop ABC Cable
Popular hnbfcable Products
0.6/1kv 2.5sqmm Single-Core XLPE Insulated PVC Sheathed Power Cable Yjlv
4 Sq mm Copper Core PVC Insulated Flexible Wire House Wiring Electric Cable
XLPE Insulated 0.6/1kv PVC Sheath Underground Aluminium Conductor Power Cable
NFC Standard ABC Cable Customized Insulation Color XLPE/PE/PVC Insulated Electric Wire
H07rn-F Copper Conductor Rubber Sheathed 3 Core Rubber Cable
NFC Standard 3X70+54.6+1X16 High Quality Aerial Bundled Cable ABC Product
Tags: 0.6/1kv LV 2*150mm2 Aerial Bundled Conductor (ABC) Cables, 1X240mm2 ABC Cable, Aluminum ABC Cable, hnbfcable