0.6/1kv Power Cable, XLPE Insulated Cable

China 
                        0.6/1kv Power Cable, XLPE Insulated Cable
                      manufacture and supplier

0.6/1kv Power Cable, XLPE Insulated Cable image

Get Latest Price Request a quote

Quick Details

0.6/1kv Power Cable, XLPE Insulated Cable

0.6/1kV power cable

Luxing Cables

Low Voltage Cables

ISO, CCC, CE, RoHS

Bare Copper Wire

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

1.5-800mm2

Steel Tape Armoured,Steel Wire Armoured

IEC, BS, VDE, GB/T

CHANG QING TENG

Wooden Drum, Steel Wooden Drum, Steel Iron Drum

0.6/1kv

Dezhou, Shandong

8544492100

Product Details

0.6/1kV power cable, XLPE Insulated Cable

1.Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.

2.Construction

1)Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, 

or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

2)Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.

3)Colour Code

Colour Code (1)

1 Core Red or Black
2 Cores Red, Black
3 Cores Red, Yellow, Blue
4 Cores Red, Yellow, Blue, Black
5 Cores Red, Yellow, Blue, Black, Green
Above 5 Cores Black Cores with White numerals

Colour Code (2)

1 Core Brown or Blue
2 Cores Brown, Blue
3 Cores Brown, Black, Grey
4 Cores Blue, Brown, Black, Grey
5 Cores Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores Black Cores with White numerals

Other colours can be manufactured upon request.

4)Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

5)Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
6)Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

7)Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Cable Parameters

1)Single core low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1×1.5 1.4 0.7 1.4 5.6
1×2.5 1.8 0.7 1.4 6.0
1×4 2.3 0.7 1.4 6.5
1×6 2.8 0.7 1.4 7.0
1×10 3.6 0.7 1.4 7.8
1×16 4.5 0.7 1.4 8.7
1×25 5.6 0.9 1.4 10.2
1×35 6.7 0.9 1.4 11.3
1×50 8.0 1 1.4 12.8
1×70 9.4 1.1 1.4 14.4
1×95 11.0 1.1 1.5 16.1
1×120 12.4 1.2 1.5 17.8
1×150 13.8 1.4 1.6 19.8
1×185 15.3 1.6 1.6 21.8
1×240 17.5 1.7 1.7 24.4
1×300 19.5 1.8 1.8 26.7
1×400 22.6 2 1.9 30.5
1×500 25.2 2.2 2.0 33.7
1×630 28.3 2.4 2.2 37.4
1×800 31.9 2.6 2.3 41.7
1×1000 35.7 2.8 2.4 46.2

2)Two cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2×1.5 1.4 0.7 1.8 9.2
2×2.5 1.8 0.7 1.8 10.0
2×4 2.3 0.7 1.8 11.0
2×6 2.8 0.7 1.8 12.0
2×10 3.6 0.7 1.8 13.6
2×16 4.5 0.7 1.8 15.4
2×25 5.6 0.9 1.8 18.4
2×35 6.7 0.9 1.8 20.6
2×50 8.0 1 1.8 23.6
2×70 9.4 1.1 1.8 26.8
2×95 11.0 1.1 1.9 30.2
2×120 12.4 1.2 2.0 33.7
2×150 13.8 1.4 2.2 37.5
2×185 15.3 1.6 2.3 41.6
2×240 17.5 1.7 2.5 46.7
2×300 19.5 1.8 2.6 51.4
2×400 22.6 2 2.9 58.9

3)Three cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3×1.5 1.4 0.7 1.8 9.6
3×2.5 1.8 0.7 1.8 10.5
3×4 2.3 0.7 1.8 11.6
3×6 2.8 0.7 1.8 12.6
3×10 3.6 0.7 1.8 14.4
3×16 4.5 0.7 1.8 16.3
3×25 5.6 0.9 1.8 19.5
3×35 6.7 0.9 1.8 21.9
3×50 8.0 1 1.8 25.1
3×70 9.4 1.1 1.9 28.7
3×95 11.0 1.1 2.0 32.4
3×120 12.4 1.2 2.1 36.1
3×150 13.8 1.4 2.3 40.3
3×185 15.3 1.6 2.4 44.6
3×240 17.5 1.7 2.6 50.2
3×300 19.5 1.8 2.7 55.2
3×400 22.6 2 3.0 63.3

4)Three cores+1 low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3×120/70 12.4 9.4 1.2 1.1 2.3 39.9
3×150/70 13.8 9.4 1.4 1.1 2.4 44.6
3×185/95 15.3 11 1.6 1.1 2.6 49.5
3×240/120 17.5 12.4 1.7 1.2 2.8 55.7
3×300/150 19.5 13.8 1.8 1.4 3.0 61.4
3×400/185 22.6 15.3 2 1.6 3.2 70.4

5)Four cores low voltage cables (unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4×1.5 1.4 0.7 1.8 10.4
4×2.5 1.8 0.7 1.8 11.3
4×4 2.3 0.7 1.8 12.5
4×6 2.8 0.7 1.8 13.7
4×10 3.6 0.7 1.8 15.7
4×16 4.5 0.7 1.8 17.8
4×25 5.6 0.9 1.8 21.5
4×35 6.7 0.9 1.8 24.1
4×50 8.0 1 1.8 27.8
4×70 9.4 1.1 2.0 32.0
4×95 11.0 1.1 2.1 36.1
4×120 12.4 1.2 2.3 40.2
4×150 13.8 1.4 2.4 44.9
4×185 15.3 1.6 2.6 49.8
4×240 17.5 1.7 2.8 56.0
4×300 19.5 1.8 3.0 61.7
4×400 22.6 2 3.2 70.7

6)Multi-cores low voltage cables(unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5×1.5 1.4 0.7 1.8 11.2
7×1.5 1.4 0.7 1.8 12.0
10×1.5 1.4 0.7 1.8 14.8
12×1.5 1.4 0.7 1.8 15.2
14×1.5 1.4 0.7 1.8 16.0
19×1.5 1.4 0.7 1.8 17.6
21×1.5 1.4 0.7 1.8 18.4
24×1.5 1.4 0.7 1.8 20.4
30×1.5 1.4 0.7 1.8 21.6
40×1.5 1.4 0.7 1.8 26.0
48×1.5 1.4 0.7 1.8 26.4
61×1.5 1.4 0.7 1.9 29.0
5×2.5 1.8 0.7 1.8 12.2
7×2.5 1.8 0.7 1.8 13.2
10×2.5 1.8 0.7 1.8 16.4
12×2.5 1.8 0.7 1.8 16.9
14×2.5 1.8 0.7 1.8 17.7
19×2.5 1.8 0.7 1.8 19.6
21×2.5 1.8 0.7 1.8 20.6
24×2.5 1.8 0.7 1.8 22.8
30×2.5 1.8 0.7 1.8 24.1
40×2.5 1.8 0.7 1.9 29.4
48×2.5 1.8 0.7 1.9 29.9
61×2.5 1.8 0.7 2.0 32.8

We are China 0.6/1kv Power Cable, XLPE Insulated Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 0.6/1kv Cables Products

  • No related articles
  • Popular 0.6/1kv Power Cable Products

    0.6/1kv Cable Cu/PVC/Swa/PVC 3X120+70mm2, 3X150+70mm2, 3X185+95mm2, 3X240+120mm2

    0.6/1kv Copper/Aluminum Power Cable 5X10, 5X16, 5X25, 5X35, 5X50, 5X70, 5X95, 5X120, 5X150mm2

    LV Power Cables (PVC Insulated) 0.6/1kv Nyy Ny2y Nyby Nyb2y Nyry Nyr2y

    0.6/1kv 1 Core Alumininum Core XLPE Insulated Power Cable

    0.6/1 Kv 95mm Copper Cable

    LV Power Cable 1000mm2 Stranded Copper XLPE PVC Insulation Low Voltage Power Cable Electric Copper LV Armoured Cable

    Popular luxingcable Products

    Medium Voltage Single Core XLPE Insulated PVC Sheathed Steel Wire Armored Electrical Power Cable

    Cu/XLPE (PVC) /Cws/Sta/Lsoh Power Cable & Electric Cable & Cable Wire 3X25 mm2

    Low Voltage XLPE Insulated/PVC Sheathed/Armoured Cable Wire

    0.6/1kv Yjv22 XLPE Armoured Power Cable

    450/750V Epr Pcp Flexible Copper Rubber Cable with H05rn-F H07rn-F Yc Ycw

    Electric Wire Multicore Flexible Cable Wire Electrical Cable Wire

    Popular Power Cable Products

    High Temperature 500V High Voltage Cable Silicone Rubber Cable

    0.6/1kv XLPE/PVC Insulation Power Cable 3*25+1*16

    Al/Cu Conductor XLPE Insulated Power Cable

    0.6/1 Kv Low Voltage 16mm2 600/1000V PVC /Swa/PVC 4 Core Cu Cable

    Medium Voltage Wire 3.6/6 (7.2) Kv XLPE Insulated Electric Wire Electric Cable Power Cable

    N2xy N2xby N2xfy/Ry 120mm2 400mm2 33kv Na2xy Yjv XLPE Copper Underground Power Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION