0.6/1kv XLPE Insulated and Armored Power Cable
0.6/1kv XLPE Insulated and Armored Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid in high fall area, able to bear external mechanical force, and certain pulling force.
Description:
1. Voltage:0.6/1KV
2. Conductor: Aluminum , Class 2
3. Insulation: PVC
4. Sheath; PVC
4.Armoured type: steel wire armoured cable(swa armoured cable also available)
Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160 ° C
Nominal cross section of conductor >300mm2: 140 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 15 times of the diameter of cable
For multi-core cable: Not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.
Technical data
Main technical data of 0.6/1KV, Single core, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Approx. diameter of steel wire(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter(mm) | Max. D.C resistance @ 200C (Ω/km) |
1x10mm2 | RM | 1.0 | 1.6 | 1.8 | 17.0 | 3.08 |
1x16mm2 | RM | 1.0 | 1.6 | 1.8 | 18.1 | 1.91 |
1x25mm2 | RM | 1.2 | 1.6 | 1.8 | 16.4 | 1.20 |
1x35mm2 | RM | 1.2 | 1.6 | 1.8 | 17.1 | 0.868 |
1x50mm2 | RM | 1.4 | 1.6 | 1.8 | 21.7 | 0.641 |
1x70mm2 | RM | 1.4 | 1.6 | 1.8 | 23.5 | 0.443 |
1x95mm2 | RM | 1.6 | 1.6 | 1.8 | 25.8 | 0.320 |
1x120mm2 | RM | 1. | 1.6 | 1.8 | 27.4 | 0.253 |
1x150mm2 | RM | 1.8 | 1.6 | 1.8 | 29.4 | 0.206 |
1x185mm2 | RM | 2.0 | 1.6 | 1.9 | 31.9 | 0.164 |
1x240mm2 | RM | 2.2 | 1.6 | 1.9 | 34.9 | 0.125 |
1x300mm2 | RM | 2.4 | 2.0 | 2.1 | 38.9 | 0.100 |
1x400mm2 | RM | 2.6 | 2.0 | 2.2 | 42.6 | 0.0778 |
1x500mm2 | RM | 2.8 | 2.0 | 2.3 | 46.3 | 0.0605 |
1x630mm2 | RM | 2.8 | 2.5 | 2.4 | 51.7 | 0.0469 |
1x800mm2 | RM | 2.8 | 2.5 | 2.6 | 56.4 | 0.0369 |
1x1000mm2 | RM | 3.0 | 2.5 | 2.7 | 61.5 | 0.029 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV, two cores, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Approx. diameter of steel wire(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter(mm) |
Max. D.C resistance @ 200C (Ω/km) |
2×1.5mm2 | RE or RM | 0.8 | 0.8 | 1.8 | 13.5 | 18.1 |
2×2.5mm2 | RE or RM | 0.8 | 0.8 | 1.8 | 14.3 | 12.1 |
2x4mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 17.1 | 7.41 |
2x6mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 18.1 | 4.61 |
2x10mm2 | RM | 1.0 | 1.6 | 1.8 | 21.7 | 3.08 |
2x16mm2 | RM | 1.0 | 1.6 | 1.8 | 23.9 | 1.91 |
2x25mm2 | SM | 1.2 | 1.6 | 1.8 | 23.2 | 1.20 |
2x35mm2 | SM | 1.2 | 1.6 | 1.8 | 24.8 | 0.868 |
2x50mm2 | SM | 1.4 | 1.6 | 1.9 | 27.5 | 0.641 |
2x70mm2 | SM | 1.4 | 2.0 | 2.0 | 31.2 | 0.443 |
2x95mm2 | SM | 1.6 | 2.0 | 2.2 | 34.7 | 0.320 |
2x120mm2 | SM | 1.6 | 2.0 | 2.3 | 37.0 | 0.253 |
2x150mm2 | SM | 1.8 | 2.5 | 2.4 | 41.3 | 0.206 |
2x185mm2 | SM | 2.0 | 2.5 | 2.5 | 44.9 | 0.164 |
2x240mm2 | SM | 2.2 | 2.5 | 2.7 | 49.6 | 0.125 |
2x300mm2 | SM | 2.4 | 2.5 | 2.9 | 54.1 | 0.100 |
2x400mm2 | SM | 2.6 | 2.5 | 3.2 | 59.3 | 0.0778 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV, three cores, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Approx. diameter of steel wire(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter(mm) |
Max. D.C resistance @ 200C (Ω/km) |
3×1.5mm2 | RE or RM | 0.8 | 0.8 | 1.8 | 14.2 | 18.1 |
3×2.5mm2 | RE or RM | 0.8 | 0.8 | 1.8 | 15.1 | 12.1 |
3x4mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 17.9 | 7.41 |
3x6mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 19.0 | 4.61 |
3x10mm2 | RM | 1.0 | 1.6 | 1.8 | 22.4 | 3.08 |
3x16mm2 | RM | 1.0 | 1.6 | 1.8 | 24.7 | 1.91 |
3x25mm2 | SM | 1.2 | 1.6 | 1.8 | 24.3 | 1.20 |
3x35mm2 | SM | 1.2 | 1.6 | 1.8 | 26.1 | 0.868 |
3x50mm2 | SM | 1.4 | 1.6 | 1.9 | 29.2 | 0.641 |
3x70mm2 | SM | 1.4 | 2.0 | 2.0 | 33.1 | 0.443 |
3x95mm2 | SM | 1.6 | 2.0 | 2.2 | 37.4 | 0.320 |
3x120mm2 | SM | 1.6 | 2.5 | 2.3 | 41.2 | 0.253 |
3x150mm2 | SM | 1.8 | 2.5 | 2.4 | 44.7 | 0.206 |
3x185mm2 | SM | 2.0 | 2.5 | 2.5 | 48.8 | 0.164 |
3x240mm2 | SM | 2.2 | 2.5 | 2.7 | 54.2 | 0.125 |
3x300mm2 | SM | 2.4 | 2.5 | 2.9 | 59.3 | 0.100 |
3x400mm2 | SM | 2.6 | 3.15 | 3.4 | 69.5 | 0.0778 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV, four cores, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Approx. diameter of steel wire(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter(mm) | Max. D.C resistance @ 200C (Ω/km) |
4×1.5mm2 | RE or RM | 0.8 | 0.8 | 1.8 | 14.9 | 18.1 |
4×2.5mm2 | RE or RM | 0.8 | 1.25 | 1.8 | 16.7 | 12.1 |
4x4mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 18.8 | 7.41 |
4x6mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 20.1 | 4.61 |
4x10mm2 | RM | 1.0 | 1.6 | 1.8 | 23.9 | 3.08 |
4x16mm2 | RM | 1.0 | 1.6 | 1.8 | 26.4 | 1.91 |
4x25mm2 | SM | 1.2 | 1.6 | 1.9 | 27.8 | 1.20 |
4x35mm2 | SM | 1.2 | 1.6 | 2.0 | 30.2 | 0.868 |
4x50mm2 | SM | 1.4 | 1.6 | 2.1 | 33.7 | 0.641 |
4x70mm2 | SM | 1.4 | 2.0 | 2.3 | 38.3 | 0.443 |
4x95mm2 | SM | 1.6 | 2.0 | 2.4 | 43.2 | 0.320 |
4x120mm2 | SM | 1.6 | 2.5 | 2.6 | 47.8 | 0.253 |
4x150mm2 | SM | 1.8 | 2.5 | 2.7 | 51.8 | 0.206 |
4x185mm2 | SM | 2.0 | 2.5 | 2.9 | 56.9 | 0.164 |
4x240mm2 | SM | 2.2 | 2.5 | 3.1 | 63.5 | 0.125 |
4x300mm2 | SM | 2.4 | 3.15 | 3.4 | 71.1 | 0.100 |
4x400mm2 | SM | 2.6 | 3.15 | 3.7 | 78.5 | 0.0778 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV, 3+1 cores, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Approx. diameter of steel wire(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
Phase core | Earth core | Phase core | Earth core | Phase core | Earth core | ||||
3×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 1.25 | 1.8 | 16.1 | 12.1 | 18.1 |
3×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 1.25 | 1.8 | 18.3 | 7.41 | 12.1 |
3×6+4mm2 | RE | RE | 1.0 | 1.0 | 1.25 | 1.8 | 19.8 | 4.61 | 7.41 |
3×10+6mm2 | RM | RE | 1.0 | 1.0 | 1.6 | 1.8 | 23.5 | 3.08 | 4.61 |
3×16+10mm2 | RM | RM | 1.0 | 1.0 | 1.6 | 1.8 | 26.2 | 1.91 | 3.08 |
3×25+16mm2 | SM | RM | 1.2 | 1.0 | 1.6 | 1.8 | 28.0 | 1.20 | 1.91 |
3×35+16mm2 | SM | RM | 1.2 | 1.0 | 1.6 | 1.8 | 29.6 | 0.868 | 1.91 |
3×50+25mm2 | SM | SM | 1.4 | 1.2 | 1.6 | 2.0 | 32.8 | 0.641 | 1.20 |
3×70+35mm2 | SM | SM | 1.4 | 1.2 | 2.0 | 2.1 | 37.4 | 0.443 | 0.868 |
3×95+50mm2 | SM | SM | 1.6 | 1.4 | 2.0 | 2.3 | 41.7 | 0.320 | 0.641 |
3×120+70mm2 | SM | SM | 1.6 | 1.4 | 2.5 | 2.4 | 46.2 | 0.253 | 0.443 |
3×150+70mm2 | SM | SM | 1.8 | 1.4 | 2.5 | 2.5 | 49.6 | 0.206 | 0.443 |
3×185+95mm2 | SM | SM | 2.0 | 1.6 | 2.5 | 2.7 | 54.5 | 0.164 | 0.320 |
3×240+120mm2 | SM | SM | 2.2 | 1.6 | 2.5 | 2.9 | 60.3 | 0.125 | 0.253 |
3×300+150mm2 | SM | SM | 2.4 | 1.8 | 2.5 | 3.1 | 65.9 | 0.100 | 0.206 |
3×400+185mm2 | SM | SM | 2.6 | 2.0 | 3.15 | 3.5 | 74.1 | 0.0778 | 0.164 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV, five cores, Aluminum conductor, PVC insulated, galvanized steel wire armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/SWA/PVC or PE
Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Approx. diameter of steel wire(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter(mm) |
Max. D.C resistance @ 200C (Ω/km) |
5×1.5mm2 | RE or RM | 0.8 | 1.25 | 1.8 | 16.7 | 18.1 |
5×2.5mm2 | RE or RM | 0.8 | 1.25 | 1.8 | 17.8 | 12.1 |
5x4mm2 | RE or RM | 1.0 | 1.25 | 1.8 | 20.2 | 7.41 |
5x6mm2 | RE or RM | 1.0 | 1.6 | 1.8 | 22.2 | 4.61 |
5x10mm2 | RM | 1.0 | 1.6 | 1.8 | 25.7 | 3.08 |
5x16mm2 | RM | 1.0 | 1.6 | 1.9 | 28.8 | 1.91 |
5x25mm2 | SM | 1.2 | 1.6 | 1.9 | 29.6 | 1.20 |
5x35mm2 | SM | 1.2 | 2.0 | 2.0 | 33.6 | 0.868 |
5x50mm2 | SM | 1.4 | 2.0 | 2.2 | 38.6 | 0.641 |
5x70mm2 | SM | 1.4 | 2.0 | 2.3 | 43.1 | 0.443 |
5x95mm2 | SM | 1.6 | 2.5 | 2.6 | 50.1 | 0.320 |
5x120mm2 | SM | 1.6 | 2.5 | 2.7 | 54.1 | 0.253 |
5x150mm2 | SM | 1.8 | 2.5 | 2.9 | 59.4 | 0.206 |
5x185mm2 | SM | 2.0 | 2.5 | 3.1 | 64.9 | 0.164 |
5x240mm2 | SM | 2.2 | 3.15 | 3.3 | 73.6 | 0.125 |
5x300mm2 | SM | 2.4 | 3.15 | 3.6 | 80.7 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Specification
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | – | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv) Item |
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Partial discharge test | Test voltage | – | – | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
Discharge capacity | – | – | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees’ number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
FAQ
Q:I didn’t find the product which I need in this page?
A:If you didn’t find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What’s your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What’s your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.
Welcome your inquiry! Any question please feel free to contact me .
We are China 0.6/1kv XLPE Insulated and Armored Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Copper Wire Products
Types of House Wiring Cu/PVC Wire 185sqmm-1c Copper Cable and Wire
XLPE /PVC Insulated Electric Copper/Aluminum Stranded Power Cable
IEC Standard LV Mv Frc Fire Retardant Cable XLPE Insulation LSZH Sheathed
Service Drop Cable Aerial Bundled Cable Twisted Aluminum ABC Cable PVC/PE Power Cable
Copper/PVC Insulated Electrical Wires 450/750V
Mica + XLPE Insulated LSZH Sheathed Fire Proof Cable IEC60332 300 / 500V
Popular kingyear Products
11kv ABC Cable Price High Tension Cable for Overhead
ASTM JIS En Standard A5250 Aluminum Plate/Sheet/Coil/Strip From Qualified Supplier
266.8mcm Partridge ACSR Aluminum Conductor Steel Reinforced Bare Conductor Electrical Calbe Price
8 /10 /14 /16 / 19 Cores Access Aircraft Control Cable
Popular Power Cable Products
Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead Cable for Power Distribution
Factory Supply Electric Power Cable XLPE Cable IEC Standard
10kv Aluminum Conductor Sta/Swa Armoured XLPE Insulated PVC Sheathed Power Cable
Low Voltage PVC Insulated PVC Sheathed Power Cable with Armor
6491b, House Wiring, Electric Wire, 450/750 V, Cu/LSZH (LS0H) Cable (BS 7211)
11kv High Voltage 300mm 150mm XLPE Insulated PVC Sheathed Steel Copper Tape Armored Power Cable
Popular XLPE Power Cable Products
11kv 15kv 20kv 33kv 35kv Medium Voltage Three Cores Underground XLPE Power Cable (1~35kV)
Duplex Triplex Quadruplex Service Drop Cable for Overhead Transmission
4 Core 50mm XLPE Insulation Copper Power Cable
XLPE Insulated 3 Cores Mv Power Cables
Medium Voltage 3 Core XLPE Insulation Swa Armoured Power Cable
Copper Conductor XLPE/PVC Insulated PE/PVC Sheathed Armored Electrical Power Cable
Tags: Copper Wire, kingyear, Power Cable, XLPE Power Cable