11kv Air Break Switch, Disconnecting Switch
11kv Air Break Switch, Disconnecting Switch image
Get Latest Price Request a quote
Quick Details
Product Details
IEC 129: 1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694: 2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.
SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30º C with a minimum of -1º C and a maximum of +40º C and heavy saline conditions along the coast.
4.2. DESIGN AND CONSTRUCTION
4.2. 1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2. 2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2. 3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2. 4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2. 5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2. 6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2. 7 The solid link shall be removable from the mounting by use of operating rod.
4.2. 8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2. 9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.
The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
We are China 11kv Air Break Switch, Disconnecting Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Disconnector Switch Products
Disconnector Switch 1000A 33kv
Gw9-15g High Voltage Isolation Switch
33kv Isolator Switch, Disconnector Switch, Silicon Gang Switch
Outdoor 3 Phase 30kv 33kv 35kv 36kv Disconnector / Isolating Switch Model Gw4
Factory Price Hotselling Customized Logo Printed Glass Insulators High Voltage
Popular jgtrade1 Products
Surge Arrester Distribution 11kv
Hot DIP Galvanized Supporting Clamps
High -Voltage Disconnect Switch 60kv 600A
Popular Rotary Switch Products
Outdoor Low Voltage Disconnect AC Disconnector Electrical Vertical Opening
Disconnecor 24kv Disconnector Switch
Air Break Swich Isolator Disconnector Switch 11kv
22kv Porcelan Pin-Type Insulator
Popular Switch Disconnector Products
High-Voltage Limit-Current Fuse for Instruments Transformer Protection
Top Selling High Power Electrical Product Fuse Cutout 24kv
Easy Assembled 245kv 1250/4000A High Voltage Disconnect Isolator Switch
Tags: Disconnector Switch, jgtrade1, Rotary Switch, Switch Disconnector