11kv XLPE Insulated Copper Core PVC Sheathed Power Cable
11kv XLPE Insulated Copper Core PVC Sheathed Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
6.0 |
2.5 |
0.12 |
1.5 |
17.6 |
0.34 |
0.49 |
1.2000 |
0.7270 |
35 |
7.0 |
2.5 |
0.12 |
1.5 |
18.5 |
0.39 |
0.60 |
0.8680 |
0.5240 |
50 |
8.3 |
2.5 |
0.12 |
1.6 |
20.0 |
0.46 |
0.74 |
0.6410 |
0.3870 |
70 |
9.7 |
2.5 |
0.12 |
1.6 |
21.5 |
0.55 |
0.96 |
0.4430 |
0.2680 |
95 |
11.3 |
2.5 |
0.12 |
1.7 |
23.3 |
0.66 |
1.23 |
0.3200 |
0.1930 |
120 |
13 |
2.5 |
0.12 |
1.7 |
24.8 |
0.77 |
1.48 |
0.2530 |
0.1530 |
150 |
14.6 |
2.5 |
0.12 |
1.8 |
26.4 |
0.87 |
1.77 |
0.2060 |
0.1240 |
185 |
15.9 |
2.5 |
0.12 |
1.8 |
28.1 |
1.01 |
2.13 |
0.1640 |
0.0991 |
240 |
18.3 |
2.6 |
0.12 |
1.9 |
30.9 |
1.23 |
2.71 |
0.1250 |
0.0754 |
300 |
20.4 |
2.8 |
0.12 |
2.0 |
33.6 |
1.48 |
3.32 |
0.1000 |
0.0601 |
400 |
23.2 |
3.0 |
0.12 |
2.1 |
37.0 |
1.81 |
4.16 |
0.0778 |
0.0470 |
500 |
26.4 |
3.2 |
0.12 |
2.2 |
41.1 |
2.24 |
5.27 |
0.0605 |
0.0366 |
630 |
30.1 |
3.2 |
0.12 |
2.3 |
45.0 |
2.73 |
6.62 |
0.0469 |
0.0283 |
2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.12 |
1.5 |
19.4 |
0.40 |
0.55 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.12 |
1.6 |
20.5 |
0.45 |
0.66 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.12 |
1.6 |
21.8 |
0.52 |
0.80 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.12 |
1.7 |
23.5 |
0.62 |
1.03 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.12 |
1.7 |
25.1 |
0.73 |
1.30 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.12 |
1.8 |
26.8 |
0.85 |
1.56 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.12 |
1.8 |
28.2 |
0.95 |
1.85 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.12 |
1.9 |
30.1 |
1.10 |
2.22 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.12 |
2.0 |
32.7 |
1.33 |
2.80 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.12 |
2.0 |
34.8 |
1.54 |
3.39 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.12 |
2.2 |
38.0 |
1.87 |
4.22 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.12 |
2.2 |
41.5 |
2.26 |
5.29 |
0.0605 |
0.0366 |
|
630 |
30.1 |
3.4 |
0.12 |
2.4 |
45.6 |
2.78 |
6.67 |
0.0469 |
0.0283 |
3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
4.5 |
0.12 |
1.6 |
21.8 |
0.48 |
0.63 |
1.2000 |
0.7270 |
|
35 |
6.9 |
4.5 |
0.12 |
1.7 |
22.9 |
0.54 |
0.75 |
0.8680 |
0.5240 |
|
50 |
8.2 |
4.5 |
0.12 |
1.7 |
24.2 |
0.61 |
0.89 |
0.6410 |
0.3870 |
|
70 |
9.7 |
4.5 |
0.12 |
1.8 |
25.9 |
0.72 |
1.13 |
0.4430 |
0.2680 |
|
95 |
11.3 |
4.5 |
0.12 |
1.8 |
27.5 |
0.84 |
1.40 |
0.3200 |
0.1930 |
|
120 |
12.8 |
4.5 |
0.12 |
1.9 |
29.2 |
0.96 |
1.67 |
0.2530 |
0.1530 |
|
150 |
14.2 |
4.5 |
0.12 |
1.9 |
30.6 |
1.06 |
1.96 |
0.2060 |
0.1240 |
|
185 |
15.9 |
4.5 |
0.12 |
2.0 |
32.5 |
1.22 |
2.34 |
0.1640 |
0.0991 |
|
240 |
18.3 |
4.5 |
0.12 |
2.1 |
35.1 |
1.46 |
2.93 |
0.1250 |
0.0754 |
|
300 |
20.4 |
4.5 |
0.12 |
2.1 |
37.2 |
1.68 |
3.52 |
0.1000 |
0.0601 |
|
400 |
23.2 |
4.5 |
0.12 |
2.2 |
40.2 |
2.00 |
4.35 |
0.0778 |
0.0470 |
|
500 |
26.4 |
4.5 |
0.12 |
2.3 |
43.9 |
2.43 |
5.45 |
0.0605 |
0.0366 |
|
630 |
30.1 |
4.5 |
0.12 |
2.4 |
47.8 |
2.93 |
6.83 |
0.0469 |
0.0283 |
4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
|
|
|
|
|
|
|
|
|
35 |
6.9 |
5.5 |
0.12 |
1.7 |
24.9 |
0.62 |
0.83 |
0.8680 |
0.5240 |
50 |
8.2 |
5.5 |
0.12 |
1.8 |
26.4 |
0.70 |
0.98 |
0.6410 |
0.3870 |
70 |
9.7 |
5.5 |
0.12 |
1.8 |
27.9 |
0.80 |
1.21 |
0.4430 |
0.2680 |
95 |
11.3 |
5.5 |
0.12 |
1.9 |
29.7 |
0.94 |
1.50 |
0.3200 |
0.1930 |
120 |
12.8 |
5.5 |
0.12 |
1.9 |
31.2 |
1.05 |
1.77 |
0.2530 |
0.1530 |
150 |
14.2 |
5.5 |
0.12 |
2.0 |
32.8 |
1.17 |
2.07 |
0.2060 |
0.1240 |
185 |
15.9 |
5.5 |
0.12 |
2.0 |
34.5 |
1.33 |
2.45 |
0.1640 |
0.0991 |
240 |
18.3 |
5.5 |
0.12 |
2.1 |
37.1 |
1.57 |
3.04 |
0.1250 |
0.0754 |
300 |
20.4 |
5.5 |
0.12 |
2.2 |
39.4 |
1.81 |
3.66 |
0.1000 |
0.0601 |
400 |
23.2 |
5.5 |
0.12 |
2.3 |
42.4 |
2.14 |
4.49 |
0.0778 |
0.0470 |
500 |
26.4 |
5.5 |
0.12 |
2.4 |
46.1 |
2.58 |
5.61 |
0.0605 |
0.0366 |
630 |
30.1 |
5.5 |
0.12 |
2.4 |
49.8 |
3.10 |
6.99 |
0.0469 |
0.0283 |
5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
|
|
|
|
|
|
|
|
|
|
35 |
|
|
|
|
|
|
|
|
|
|
50 |
8.2 |
8.0 |
0.12 |
2.0 |
31.8 |
0.95 |
1.23 |
0.6410 |
0.3870 |
|
70 |
9.7 |
8.0 |
0.12 |
2.0 |
33.3 |
1.07 |
1.47 |
0.4430 |
0.2680 |
|
95 |
11.3 |
8.0 |
0.12 |
2.1 |
35.1 |
1.21 |
1.78 |
0.3200 |
0.1930 |
|
120 |
12.8 |
8.0 |
0.12 |
2.1 |
36.6 |
1.34 |
2.05 |
0.2530 |
0.1530 |
|
150 |
14.2 |
8.0 |
0.12 |
2.2 |
38.2 |
1.47 |
2.37 |
0.2060 |
0.1240 |
|
185 |
15.9 |
8.0 |
0.12 |
2.2 |
39.9 |
1.64 |
2.76 |
0.1640 |
0.0991 |
|
240 |
18.3 |
8.0 |
0.12 |
2.3 |
42.5 |
1.90 |
3.37 |
0.1250 |
0.0754 |
|
300 |
20.4 |
8.0 |
0.12 |
2.4 |
44.8 |
2.16 |
4.01 |
0.1000 |
0.0601 |
|
400 |
23.2 |
8.0 |
0.12 |
2.4 |
47.6 |
2.52 |
4.87 |
0.0778 |
0.0470 |
|
500 |
26.4 |
8.0 |
0.12 |
2.5 |
51.3 |
2.98 |
6.01 |
0.0605 |
0.0366 |
|
630 |
30.1 |
8.0 |
0.12 |
2.6 |
55.2 |
3.54 |
7.43 |
0.0469 |
0.0283 |
6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
2.5 |
0.1 |
2.0 |
34.6 |
1.13 |
1.58 |
1.2000 |
0.7270 |
||
35 |
6.9 |
2.5 |
0.1 |
2.1 |
36.8 |
1.29 |
1.92 |
0.8680 |
0.5240 |
||
50 |
8.2 |
2.5 |
0.1 |
2.2 |
39.8 |
1.51 |
2.36 |
0.6410 |
0.3870 |
||
70 |
9.7 |
2.5 |
0.1 |
2.3 |
43.2 |
1.81 |
3.04 |
0.4430 |
0.2680 |
||
95 |
11.3 |
2.5 |
0.1 |
2.4 |
46.9 |
2.17 |
3.87 |
0.3200 |
0.1930 |
||
120 |
12.8 |
2.5 |
0.1 |
2.4 |
50.1 |
2.53 |
4.69 |
0.2530 |
0.1530 |
||
150 |
14.2 |
2.5 |
0.1 |
2.5 |
53.3 |
2.90 |
5.60 |
0.2060 |
0.1240 |
||
185 |
15.9 |
2.5 |
0.1 |
2.6 |
57.2 |
3.40 |
6.77 |
0.1640 |
0.0991 |
||
240 |
18.3 |
2.6 |
0.1 |
2.8 |
63.2 |
4.12 |
8.55 |
0.1250 |
0.0754 |
||
300 |
20.4 |
2.8 |
0.1 |
3.0 |
69.0 |
4.89 |
10.46 |
0.1000 |
0.0601 |
||
400 |
23.2 |
3.0 |
0.1 |
3.4 |
76.7 |
6.10 |
13.18 |
0.0778 |
0.0470 |
||
500 |
26.4 |
3.2 |
0.1 |
3.6 |
85.7 |
8.10 |
16.55 |
0.0605 |
0.0366 |
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.1 |
2.1 |
38.7 |
1.30 |
1.75 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.1 |
2.2 |
40.9 |
1.47 |
2.22 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.1 |
2.3 |
43.9 |
1.70 |
2.50 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.1 |
2.4 |
47.3 |
2.02 |
3.25 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.1 |
2.5 |
51.0 |
2.42 |
4.12 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.1 |
2.6 |
54.4 |
2.79 |
4.95 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.1 |
2.7 |
57.6 |
3.17 |
5.87 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.1 |
2.8 |
61.5 |
3.69 |
7.06 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.1 |
2.9 |
66.9 |
4.38 |
8.82 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.1 |
3.1 |
71.8 |
5.11 |
10.68 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.1 |
3.3 |
78.3 |
6.24 |
13.32 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.1 |
3.5 |
86.4 |
7.63 |
16.50 |
0.0605 |
0.0366 |
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
4.5 |
0.1 |
2.3 |
43.9 |
1.57 |
2.02 |
0.9270 |
0.7270 |
||
35 |
6.9 |
4.5 |
0.1 |
2.4 |
46.0 |
1.75 |
2.38 |
0.6680 |
0.5240 |
||
50 |
8.2 |
4.5 |
0.1 |
2.4 |
48.8 |
2.00 |
2.85 |
0.4936 |
0.3870 |
||
70 |
9.7 |
4.5 |
0.1 |
2.5 |
52.3 |
2.34 |
3.57 |
0.3420 |
0.2680 |
||
95 |
11.3 |
4.5 |
0.1 |
2.6 |
55.9 |
2.75 |
4.45 |
0.2464 |
0.1930 |
||
120 |
12.8 |
4.5 |
0.1 |
2.7 |
59.4 |
3.16 |
5.32 |
0.1955 |
0.1530 |
||
150 |
14.2 |
4.5 |
0.1 |
2.8 |
62.6 |
3.57 |
6.27 |
0.1587 |
0.1240 |
||
185 |
15.9 |
4.5 |
0.1 |
2.9 |
66.4 |
4.07 |
7.45 |
0.1271 |
0.0991 |
||
240 |
18.3 |
4.5 |
0.1 |
3.1 |
72.0 |
4.82 |
9.25 |
0.0976 |
0.0754 |
||
300 |
20.4 |
4.5 |
0.1 |
3.3 |
77.0 |
5.71 |
11.28 |
0.0778 |
0.0601 |
||
400 |
23.2 |
4.5 |
0.1 |
3.4 |
83.2 |
6.78 |
13.86 |
0.0615 |
0.0470 |
||
500 |
26.4 |
4.5 |
0.1 |
3.5 |
91.1 |
8.20 |
17.32 |
0.0487 |
0.0366 |
9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm2 |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
– |
|
|
|
|
|
|
|
|
||
35 |
6.9 |
5.5 |
0.1 |
2.4 |
50.3 |
2.00 |
2.63 |
0.8680 |
0.6680 |
||
50 |
8.2 |
5.5 |
0.1 |
2.5 |
53.3 |
2.26 |
3.11 |
0.6410 |
0.4936 |
||
70 |
9.7 |
5.5 |
0.1 |
2.6 |
56.8 |
2.62 |
3.85 |
0.4430 |
0.3420 |
||
95 |
11.3 |
5.5 |
0.1 |
2.8 |
60.6 |
3.07 |
4.77 |
0.3200 |
0.2464 |
||
120 |
12.8 |
5.5 |
0.1 |
2.9 |
64.1 |
3.49 |
5.65 |
0.2530 |
0.1955 |
||
150 |
14.2 |
5.5 |
0.1 |
3.0 |
67.3 |
3.91 |
6.61 |
0.2060 |
0.1587 |
||
185 |
15.9 |
5.5 |
0.1 |
3.1 |
71.2 |
4.44 |
7.81 |
0.1640 |
0.1271 |
||
240 |
18.3 |
5.5 |
0.1 |
3.3 |
76.8 |
5.21 |
9.64 |
0.1250 |
0.0976 |
||
300 |
20.4 |
5.5 |
0.1 |
3.3 |
81.3 |
6.10 |
11.66 |
0.1000 |
0.0778 |
||
400 |
23.2 |
5.5 |
0.1 |
3.5 |
87.7 |
7.20 |
14.28 |
0.0778 |
0.0615 |
||
500 |
26.4 |
5.5 |
0.1 |
3.8 |
96.0 |
9.15 |
17.80 |
0.0605 |
0.0487 |
10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
|
|
|
|
|
|
|
|
|
35 |
|
|
|
|
|
|
|
|
|
50 |
8.2 |
8.0 |
0.1 |
2.9 |
64.9 |
3.02 |
3.87 |
0.6410 |
0.4936 |
70 |
9.7 |
8.0 |
0.1 |
3.0 |
68.4 |
3.42 |
4.65 |
0.4430 |
0.3420 |
95 |
11.3 |
8.0 |
0.1 |
3.1 |
72.0 |
3.89 |
5.59 |
0.3200 |
0.2464 |
120 |
12.8 |
8.0 |
0.1 |
3.3 |
75.7 |
4.39 |
6.54 |
0.2530 |
0.1955 |
150 |
14.2 |
8.0 |
0.1 |
3.3 |
78.7 |
4.85 |
7.55 |
0.2060 |
0.1587 |
185 |
15.9 |
8.0 |
0.1 |
3.4 |
82.6 |
5.42 |
8.79 |
0.1640 |
0.1271 |
240 |
18.3 |
8.0 |
0.1 |
3.5 |
88.0 |
6.22 |
10.66 |
0.1250 |
0.0976 |
300 |
20.4 |
8.0 |
0.1 |
3.7 |
92.9 |
7.20 |
12.77 |
0.1000 |
0.0778 |
400 |
23.2 |
8.0 |
0.1 |
3.9 |
99.3 |
8.38 |
15.46 |
0.0778 |
0.0615 |
500 |
26.4 |
8.0 |
0.1 |
4.2 |
107.6 |
10.15 |
18.85 |
0.0605 |
0.0487 |
We are China 11kv XLPE Insulated Copper Core PVC Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 11kv XLPE Insulated Copper Core PVC Sheathed Power Cable Products
Popular Cable Products
Power Transmitting ABC Cable Duplex Al/PE Overhead Cable
3 Core Medium Voltage Armored Cable XLPE Insulation 11kv Power Cable
4X10mm2 Copper PVC Power Cable
ASTM Standard All Aluminum AAC Overhead Conductor
Underground Cable with PVC Insulation and PVC Sheath Nayy Nyy Cable
Popular jpcable99 Products
Henan Jiapu Cable Good Quality PVC Insulated Wire
High Quality ABC Cable with IEC Standard
Low Voltage Aerial Bundled Cable
PVC Insulated and Sheathed Cable with Reasonable Price
3X70mm2 XLPE Insulated Armoured Power Cable
High Quality PVC Insulated Building Wire
Popular Power Cable Products
Bare Power Transmission IEC Standard Overhead ACSR Cable
AS/NZS SDI 1c35 Copper XLPE Power Cable
Aluminum Conductive Core PVC PE Sheath 2 Core Power Cable
450/750V Copper Conductor Al Foil Wire Shield Electrical Wire Cable
XLPE Insulation Cppper Wire Screen XLPE Sheath Cable
Tags: 11kv XLPE Insulated Copper Core PVC Sheathed Power Cable, Cable, jpcable99, Power Cable