12kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
12kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line image
Get Latest Price Request a quote
Basic Info.
Product Description
Surge Arrester Series
General
1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite)
2. Application:for protection of power transmission & distribution system from over-voltage.
3. Features:
1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.
2)Easy installation and maintenance.
3)Good sealing capability to ensure reliable operation.
4)Protection and reliability of the surge arrester have been greatly enhanced.
Working Condition
1. Ambient air temperature:-40ºC ~+40ºC ;
2. Altitude:<=2000m;
3. Frequency: 48Hz~62Hz;
4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter;
5. Earthquake intensity is less than 8 degree;
6. Max. Wind speed is 35m/s.
Main Techical Parameter
1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-5W-6 | 6 | 5.1 | 18 | 320 | 150 | 65 | |
| YH-5W-9 | 9 | 7.65 | 27 | 430 | 150 | 65 | |
| YH-5W-12 | 12 | 10.2 | 36 | 430 | 150 | 65 | |
| YH-5W-15 | 15 | 12.75 | 45 | 530 | 150 | 65 | |
| YH-5W-18 | 18 |
15.3 |
54 | 530 | 150 | 65 | |
| YH-5W-21 | 21 | 16.8 | 63 | 640 | 150 | 65 | |
| YH-5W-24 | 24 | 19.2 | 72 | 640 | 150 | 65 | |
| YH-5W-27 | 27 | 21.6 | 81 | 740 | 150 | 65 | |
| YH-5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| YH-5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| YH-5W-36 | 36 | 28.8 | 108 | 1115 | 150 | 65 |
2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-10W-6 | 6 | 5.1 | 18 | 1 | 320 | 250 | 100 |
| YH-10W-9 | 9 | 7.65 | 27 | 1 | 430 | 250 | 100 |
| YH-10W-12 | 12 | 10.2 | 36 | 1 | 430 | 250 | 100 |
| YH-10W-15 | 15 | 12.75 | 45 | 1 | 530 | 250 | 100 |
| YH-10W-18 | 18 | 15.3 | 54 | 1 | 530 | 250 | 100 |
| YH-10W-21 | 21 | 16.8 | 63 | 1 | 640 | 250 | 100 |
| YH-10W-24 | 24 | 19.2 | 72 | 1 | 740 | 250 | 100 |
| YH-10W-27 | 27 | 21.6 | 81 | 1 | 740 | 250 | 100 |
| YH-10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| YH-10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| YH-10W-36 | 36 | 28.8 | 108 | 1 | 1115 | 250 | 100 |
| YH-10W-42 | 42 | 33.6 | 126 | 2 | 1260 | 400 | 100 |
| YH-10W-48 | 48 | 39 | 139 | 2 | 1260 | 400 | 100 |
| YH-10W-54 | 54 | 42 | 160 | 2 | 1260 | 400 | 100 |
| YH-10W-60 | 60 | 48 | 178 | 2 | 1465 | 400 | 100 |
| YH-10W-66 | 66 | 52.8 | 196 | 2 | 1465 | 400 | 100 |
| YH-10W-72 | 72 | 57 | 214 | 2 | 2255 | 400 | 100 |
| YH-10W-84 | 84 | 67.2 | 244 | 2 | 2255 | 400 | 100 |
| YH-10W-90 | 90 | 72.5 | 249 | 2 | 2255 | 400 | 100 |
| YH-10W-96 | 96 | 75 | 265 | 3 | 3555 | 800 | 100 |
| YH-10W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-10W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-10W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-10W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-20W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-20W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-20W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y5W-6 | 6 | 5.1 | 18 | 280 | 150 | 65 | |
| Y5W-9 | 9 | 7.65 | 27 | 320 | 150 | 65 | |
| Y5W-12 | 12 | 10.2 | 36 | 320 | 150 | 65 | |
| Y5W-15 | 15 | 12.75 | 45 | 450 | 150 | 65 | |
| Y5W-18 | 18 |
15.3 |
54 | 450 | 150 | 65 | |
| Y5W-21 | 21 | 16.8 | 63 | 450 | 150 | 65 | |
| Y5W-24 | 24 | 19.2 | 72 | 510 | 150 | 65 | |
| Y5W-27 | 27 | 21.6 | 81 | 510 | 150 | 65 | |
| Y5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| Y5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| Y5W-36 | 36 | 28.8 | 108 | 890 | 150 | 65 |
5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y10W-6 | 6 | 5.1 | 18 | 1 | 280 | 250 | 100 |
| Y10W-9 | 9 | 7.65 | 27 | 1 | 320 | 250 | 100 |
| Y10W-12 | 12 | 10.2 | 36 | 1 | 320 | 250 | 100 |
| Y10W-15 | 15 | 12.75 | 45 | 1 | 450 | 250 | 100 |
| Y10W-18 | 18 | 15.3 | 54 | 1 | 450 | 250 | 100 |
| Y10W-21 | 21 | 16.8 | 63 | 1 | 450 | 250 | 100 |
| Y10W-24 | 24 | 19.2 | 72 | 1 | 510 | 250 | 100 |
| Y10W-27 | 27 | 21.6 | 81 | 1 | 510 | 250 | 100 |
| Y10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| Y10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| Y10W-36 | 36 | 28.8 | 108 | 1 | 890 | 250 | 100 |
| Y10W-42 | 42 | 33.6 | 126 | 2 | 1256 | 400 | 100 |
| Y10W-48 | 48 | 39 | 139 | 2 | 1256 | 400 | 100 |
| Y10W-54 | 54 | 42 | 160 | 2 | 1256 | 400 | 100 |
| Y10W-60 | 60 | 48 | 178 | 2 | 1440 | 400 | 100 |
| Y10W-66 | 66 | 52.8 | 196 | 2 | 1440 | 400 | 100 |
| Y10W-72 | 72 | 57 | 214 | 2 | 1440 | 400 | 100 |
| Y10W-84 | 84 | 67.2 | 244 | 2 | 2200 | 400 | 100 |
| Y10W-90 | 90 | 72.5 | 249 | 2 | 2200 | 400 | 100 |
| Y10W-96 | 96 | 75 | 265 | 3 | 3350 | 800 | 100 |
| Y10W-108 | 108 | 84 | 281 | 3 | 3350 | 800 | 100 |
| Y10W-120 | 120 | 96 | 300 | 3 | 3948 | 800 | 100 |
| Y10W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y10W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| Y20W-120 | 120 | 96 | 300 | 3 | 4106 | 800 | 100 |
| Y20W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y20W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
| Y20W-444 | 444 | 324 | 1106 | 4 | 17052 | 2000 | 100 |
Note: For details, please refer to the catalogue.
Participate in the exhibition pictures
testing report
We are China 12kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 12kv Polymer Housing Lightning Arrester Products
Popular Oxide Zinc Lightning Arrester Products
15kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
30kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
6kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
36kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
9kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
27kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
Popular people Products
Zc1-Hzc1 11kv Drop out Fuse Cutout
Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout
Hot DIP Galvanization Bolt and Nut
27kv Outdoor Distribution Systems Disconnect Switch
Outdoor High Voltage Fuse Cutout
100kn Electrified Railways Composite Insulators
Popular Polymer Housing Lightning Arrester Products
33kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
18kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
27kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
15kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
21kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
36kv Polymer Housing Oxide Zinc Lightning Arrester on Transmission Line
Tags: 12kv Polymer Housing Lightning Arrester, Oxide Zinc Lightning Arrester, people, Polymer Housing Lightning Arrester