132kv 11.5kv 25mva Mobile Substation
132kv 11.5kv 25mva Mobile Substation image
Get Latest Price Request a quote
Basic Info.
Product Description
Czbt1-132kv 132kv/11.5KV movable Mobile power transofrmer substation
Outdoor,dust and water proof (132/11.5)kv,25mva Mobile substation according to IEC standard .
The Mobile substation consists of two trailer(A&B).
Trailer (A) Carries the following equipments:
* Three pcs lighting arrester of (120kv,10ka) .
*3-phase,two-pole,vertical break(145kv,630A,31.5KA/1SEC).disconnected switch with earth switch at transformer side.
*3-phase,vacuum circuit breaker(145kv,630a,31.5KA/1SEC).with spring operating mechanism.
*One,3-phase(132kv/11.5kv)25mva YND11 oil immersed power transformer with (17) steps on load tap changer(OLTC) at high voltage side with regulatio( ±10% of 132kv).
*One pcs lighting arrester of (75kv,10ka)at neutral point of 25mva power transformer.
*One,3-phase,75kva,11.5kv/380v-220v,znyn1,auxiliary&earthing transformer with neutral current 300A/10SEC.
*Safety fence.
*All current transformers for 132kv side and neutral point are bushing types.
Trailer (B) Carry the following equipments:
One cabinet dust and water proof contain the control panel,protection panel,A,C distribution board,metering and energy board and equipped with suitable air condition.
One cabinet contain the 12kv,air-insulation metal-enclosed switchgear the switchgear consists of (one panel for 12kv voltage transformer with surge arrester,one panel for 12kv incoming feeder,five panels for out going feeders).
One Cabinet contain 110V,D.C system( charger,battery and D.C distribution board) with suitable ventilation
132kv system
*Highest system voltage 145kv
*Impulse with stand voltage
For Bushing 650KV
For winding 550KV
For Neutral 350KV
*Power frequency withstand test voltage(for 1min)
For Bushing 275kv
For winding 230kv
For Neutral 140KV
*Rated breaking capacity 31.5ka
Creeage distance ≥ 25mm/KV
11.5KV System
*Highest system voltage 12kv
Impulse with stand voltage
For Bushing 75kv
for winding 75kv
for neutral 75kv
*power frequency withstand test voltage(for 1 min).
For bushing 28kv
for winding 28kv
for neutral 28kv
*Rated breaking capacity 31.5KA
Creepage distance ≥25mm/KV
Technical feature:
of emergency.
with booming power demands that exceed the existing electric power capability,to ease the tension of power supply.
investment in various aspects, concerning the land requisition, civil construction,equipment installation etc, which improves the reliability
of power supply for the system.
quick into the service. It could be into operation at once on site after the connection of input and output cable only.
Technical parameters
Main transformer capacity ( MVA): 5, 7.5, 10, 15, 20, 25, 31.5;
HV side Swith gear rated voltage ( KV ): 33, 66, 77, 110, 132, 138:
Rated current (A): 1250A, 2000A;
Rated short circuit break current (KA): 25, 31.5, 40;
LV side Switch gear rated voltage (KV): 6.6, 11, 13.8, 22, 33:
Rated current (A): 1250, 2000, 2500, 3150;
Rated short circuit break current (KA): 25, 31.5, 40
Our workshop
Our international sales team
Our Services
1. |
Pre sale service |
a. |
make technical solution |
b. |
send quotation, technical data sheet and drawing |
c. |
prepare power transmission plan, testing plan,and shipment plan |
2. |
In sale service |
a. |
supervise the manufacturing schedule totally in accordance with the plan |
b. |
send photos to customer during every manufacturing process(hold point) |
c. |
inform the customer one week before testinng. |
3. |
After sale service |
a. |
installation and commissioning, training the workers |
b. |
quick response within 12 hours any time |
c. |
provide 12 months gurantee period normally. |
Order Instructions
When you choose our company product, please offer following data:
Transformer model:
Rated capacity: kVA
Phase:Three-phase
Single-phase
Frequency:50HZ
60HZ
Rated voltage ( H.V. / L.V. ):
Tapping range: ± × %
Insulation level: LI AC / LI AC kv
Veotor group:Dyn11
Yyno
Other
Short-circuit Impedance: %
Cooling method:ONAN
ONAF
Tapping method:OLTC
OCTC
Other
Single line diagram for mobile substation
Other requirement:
Notes:
We also can design special products according to customer’s particular requirements.
The final dimension is subject to outline drawing.
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 132kv 11.5kv 25mva Mobile Substation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 132kv /11.5kv Substation Products
Popular 132kv 11.5kv 25mva Mobile Substation Products
Popular 25mva Mobile Power Substation Products
Popular cnville Products
3t Electric Arc Furnace for Steel Melting
Sf10-75000/110 75mva 110kv Dual-Winding No-Load Tapping Power Transformer
Modular Power Electrical Transformer Susbstation
S11-4000/35 4mva S11 Series 35kv Power Transformer with on Load Tap Changer
Tags: 132kv /11.5kv Substation, 132kv 11.5kv 25mva Mobile Substation, 25mva Mobile Power Substation, cnville