132kv Three-Phase off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise

China 
                        132kv Three-Phase off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise
                      manufacture and supplier

132kv Three-Phase off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise image

Get Latest Price Request a quote

Quick Details

132kv Three-Phase off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise

132kv Three-phase Off-circuit Tap Changing Power T

Silverstone Electric

OD

Power Frequency

Power Transformer

ISO9001-2000, ISO9001

Separated Winding Transformer

Oil-immersed Type Transformer

Core-type Transformer

Three

Power, Instrument, Lighting, Rectifier

Silverstone Electric

Pallet / Wooden Case / Container

Refer to Drawings

China

Product Details

Features of 132kV Oil-immersed Transformers (33kV Large Capacity main
Transformers)
1. Low loss, therefore significantly energy-saving. The average no-load loss is 35% lower, and the load loss 10~20% lower, than
Prescribed by the present National standard GB/T 6451.
2. The core laminations are made up from imported high-quality cold-rolled grain-oriented silicon steel sheets with miter joints
And without punched holes, and are stacked without the upper yoke sheets in place. After stacking, the core is pressed
Integrally and finally glued together by epoxy resin on the cut edges, so that the three limbs and the upper and lower yokes are
Bonded together into a rigid, vertically straightened entity, together with the plate-type upper and lower frame.
3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly, thus
Reducing the temperature rise of the windings as a whole as well as the hot-spot temperature rise, prolonging the service life
Of transformers.
4. The regulating winding is a separate winding, apart from the high voltage main winding. In this way, total ampere-turn balance
Between windings can be obtained irrespective of the tapping position; And the axial electrodynamic force during short circuit
Can be much reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. All the windings are
Perfectly dried before assembly. The radial clearances between windings and between low voltage winding and core are filled
With pre-dried vertical spacers and insulating cylinders in such a way that the windings are tightly together radially with
Practically ‘zero’ allowance between them.
5. The windings of one phase are assembled into an integral phase block before placing onto the core. The low voltage winding is
Wound directly on strong thick paper cylinder. Vertical spacer strips are provided in spaces between windings and outside the
Outermost winding. The radial dimensions of all windings are kept within strict tolerance, so that a rigid winding phase block
Are obtained, capable of withstanding all the radial short-circuit forces encountered in service, and the possibility of buckling
Of the inner winding is obviated. Axially, the height of all windings is kept within close tolerance. Horizontal spacers between
Discs of a winding are pre-densified. The assembled winding phase black are pressed up and down by single support and
Pressure plates after careful adjustment of the heights of individual windings. Axial pressures are co-ordinated with the
Calculated short circuit force, so that the capability of the transformer to withstand axial short-circuit force is much increased.
6. The winding manufacture, winding assembly, and core and winding assembly work are all proceeded in totally closed clean
Rooms inside workshops. The cleanliness and temperature stability requirement of the area are the same as that required for
The manufacture of 500kV class transformers. The final vapor phase drying of the core and coil assembly is practically a further
Cleaning process.
7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil
Assembly is fixed in the tank, being positioned against the tank at six sides rigidly, such that there can be no displacement of
The assembly due to impacts during transport. Three-dimensional impact recorders are installed on transformers during
Transport to detect whether or not unacceptable impact force has been experienced and displacement of the core and coil
Assembly occurred during transportation. If not, lifting of the core and coil assembly out of the tank is not necessary. Flat cover
Permits the bushings

We are China 132kv Three-Phase off-Circuit Tap Changing Power Transformers with Low-Loss and Low-Noise manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Amorphous Transformer Products

20kv 24kv 50-3150kVA Distribution Transformer

Dry-Type 11kv 33kv Transformer Dimensions with Protection Enclosure

Step Voltage Regulator 11kv Voltage Stabilizer

Pole Mounted Three Phase Overhead Distribution Transformer

Dry Type Scz11-33kv Power Transformers with on-Load Tap Changer

Sc10-30~1000kVA 11kv Distribution Core Type Transformer

Popular Oil Transformet Products

33kv Traction Transformer Tap Changing Oltc

69kv 66kv Oil-Immersed Power Transformer

Manufacturer 11kv 630~2500kVA Distribution Transformers

Sz11 Type on Load Tap Changer Transformer 11kv

132kv Level and Below Furnace Transformer Tap Changing Oltc IEC

110kv and Above Rectifier Special Transformer

Popular Power Transformer Products

D11 Single-Phase Oil-Immersed Transformer 11kv

Energy Saving Delta Core Oil Immersed Transformer

Hollow Porcelain Insulators for Power Transformer

11kv - 230kv Rectifier Special Transformer

50-3150kVA 20kv 24kv Distribution Transformer

Step Voltage Regulator 11kv Voltage Transformer

Popular silverstone-electric Products

Aluminum Alloy Nll/Nld Tension Clamp/Strain Clamp/Cable Clamp with U Boits

Vintage Brown Normal Type Disc Suspension Ceramic Insulators ANSI

PT Integrate Connecting Insulator Epoxy Resin Insulator

Split Core Current Transformer/Clamp-on Current Transformer

24kv Oil Immersed Distribution Transformer

Furnace Transformer with Tap Changing Oltc 33kv Level and Below

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION