1350 Aluminum XLPE Insulaton Concentric Cable 2X8AWG, 2X6AWG, 3X6AWG Have Test Reports
1350 Aluminum XLPE Insulaton Concentric Cable 2X8AWG, 2X6AWG, 3X6AWG Have Test Reports image
Get Latest Price Request a quote
- Overview
- Product Description
- Certifications
- Company Profile
- FAQ
- Quality Assurance
- Customers
Basic Info.
Product Description
1. STANDARD
The concentric conductors of copper and aluminum, is entirely consistent with the rules ASTM D 790, D 1248, D 2655, D 2656, UL 854, UL 44, .
2. CHARACTERISTICS OF THE COPPER AND ALUMINUM CONDUCTORS
The concentric conductors of copper and aluminum, is entirely consistent with the rules ASTM D 790, D 1248, D 2655, D 2656, UL 854, UL 44,ASTM B 801, ASTM B800 .
2.1 CONSTRUCTIVE CHARACTERISTICS
Each material used in the conductor will be compatible with all other materials used in the manufacture of concentric conductor.
Concentric conductor consists of one or two conductors which in turn are coated with a bare conductor distributed helically around the conductors.
According to these configurations will have a phase and outer concentric neutral (bipolar), or two phases and these external neutral (tripolar)
Section of all conductors that form the concentric conductor of both phases as the concentric neutral is the same.
Conductor:
The materials used in the manufacture of concentric aluminum conductors formed by wires aluminum 8000 serises , or 1350 Al, or Copper
shall comply with the provisions of ASTM standard .
Isolation:
Each phase conductor will contain an insulating layer of XLPE for a temperature of 90 C. in the bipolar cables, over the insulating layer will be the braided neutral conductor helically with a passage between 8 and 16 times the outer diameter. In the tripolar cables over the isolation of each phase will have a PVC insulation filling in the joint of both cables and over this will be placed the neutral conductor.
Will be put over the concentric neutral conductor a tape and over this outer layer of PVC. Must ensure the tightness of the set plus adequate resistance to ultraviolet rays (UV),Covering the entire concentric conductor will be placed a PVC coating.
CONCENTRIC CONDUCTORS AL | ||||||
FEATURES | #8 x 2 | #8 x 3 | #6 x 3 | #4 x 3 | #2 x 3 | |
Phase | Material | Al | Al | Al | Al | Al |
No. Of wires | 7 | 7 | 7 | 7 | 7 | |
Wire diameter (m.m.) | 1,234 | 1,234 | 1,555 | 1,961 | 2,473 | |
phase diameter (m.m.) | 3.71 | 3.71 | 4.67 | 5.89 | 7.42 | |
Phase area (mm²) | 8,367 | 8,367 | 13.3 | 21.15 | 33.62 | |
Nominal electrical resistance C.C. a 20°C Ohm/Km. | 3.43 | 3.43 | 2.16 | 1.36 | 0.855 | |
Nominal weight Kg/Km | 22.69 | 22.69 | 247 | 57.37 | 91.21 | |
Ampacity (A) | 45 | 45 | 60 | 75 | 100 | |
Phase Insulation thickness (m.m.) (PE) | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | |
Diameter over insulation | 5.99 | 5.99 | 6.95 | 8.17 | 9.7 | |
Neutral | No. Of wires | 37 | 37 | 37 | 65 | 65 |
Wire diameter (m.m.) | 0.536 | 0.536 | 0.676 | 0.643 | 0.823 | |
Area of Neutral (mm²) | 8.349 | 8.349 | 13.280 | 21.107 | 34.578 | |
Interior Nylon tape thickness (mm²) | 0.05 | |||||
Exterior Thickness for PE cover (mm²) | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 |
Registered capital 30 million RMB, our company have more than 80 sets of advanced production equipment and 23 sets of measurement testing equipment. the mainly products are XLPE cable, PVC Wire, Service drop wire, Aerial Bundle Cable, AAC, AAAC, ACSR, Concentric cable,Poly wire ,15-35kV Tree wire, Power cable etc.
Since the company established ,Our partner relationship spreads all over Mid-East ,Southeast Asia, Africa, Europe,North and South American and so on
Our principle is "integrity Service, pragmatic innovation, pursuit excellence"
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last.
Welcome to visit us. We’ll pick you up in Zhengzhou
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What’s your Minimum Order Quantity?
Normally 1000m. However, the cable is very heavy.
You’d better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company.
We are China 1350 Aluminum XLPE Insulaton Concentric Cable 2X8AWG, 2X6AWG, 3X6AWG Have Test Reports manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1350 Aluminum XLPE Insulaton Concentric Cable 2X8AWG Products
Popular 2X6AWG Products
AA8000 Concentrico De Conductor 2X8AWG and 3X6AWG, 3X4AWG, 2X6AWG
Popular 3X6AWG Have Test Reports Products
Popular Concentric Cable Products
Copper Conductor 2 Core Flat Concentric Cable 16mm2
Low Voltage Stranded Copper/Aluminum Conductor Concentric Cable
16sqmm Concentric Service Cable with 4 Communication Cable
ASTM 600/100V Copper Core Concentric Cable
Concentric XLPE Solid Aluminum Cable 16mm2 with 33kV Distribution Line
High Quality 0.6/1kv XLPE Insulated Concentric Copper Power Cable with Factory Price
Tags: 1350 Aluminum XLPE Insulaton Concentric Cable 2X8AWG, 2X6AWG, 3X6AWG Have Test Reports, Concentric Cable, Concentrico Cable, zmlcable