15kv 100% Neutral 133% Medium Voltage Cable Tr-XLPE Insulated 4/0 Urd Cable

China 
                        15kv 100% Neutral 133% Medium Voltage Cable Tr-XLPE Insulated 4/0 Urd Cable
                      manufacture and supplier

15kv 100% Neutral 133% Medium Voltage Cable Tr-XLPE Insulated 4/0 Urd Cable image

Get Latest Price Request a quote

Quick Details

15kv 100% Neutral 133% Medium Voltage Cable Tr-XLPE Insulated 4/0 Urd Cable

OEM

YJV

ISO, CCC

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station, Telecommunication

OEM

in Drum or in Coil

4*35

Henan

8544492100

Product Details

Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable.
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.
 
Application: 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
        
Mobile: +86 15037165923       

Using features: 
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC. 
4. D. C. Resistance of the conductor complies with the stipulations of international standar. 
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated. 
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter. 
7. Working Frequency Voltage Test: 
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
 
This series includes:
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables

       
Mobile: +86 15037165923       

We are China 15kv 100% Neutral 133% Medium Voltage Cable Tr-XLPE Insulated 4/0 Urd Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 133% Medium Voltage Cable Products

  • No related articles
  • Popular 15kv 100% Neutral Urd Cable Products

  • No related articles
  • Popular Tr-XLPE Insulated 4/0 Urd Cable Products

  • No related articles
  • Popular zzhongdacable Products

    Yy Cy Sy Cable 3G1.5 3G2.5 5g1.5 5g2.5 for Control System Flexible PVC Cable

    Single Core Overhead Aluminum Cable XLPE Insulated 6mm2 ABC Cable

    Cu/XLPE/PVC, XLPE Control Cable, 0.6/1 Kv (IEC 60502-1)

    PVC Insulated 50 Sq mm 95mm 35mm 25mm Copper Aluminum Electrical Power Cable

    Overhead AAC/AAAC/ACSR/Acar Bare Conductor Electrical Conductor

    Bare Ground Copper Cable 2AWG 2/0AWG 4/0AWG 4AWG

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION