15kv Primary Ud Cable Trxlp Insulation
15kv Primary Ud Cable Trxlp Insulation image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Predominantly used for primary underground distribution; suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.
Specifications:
15kV HI-DRI Primary UD Cable meets or exceeds the following ASTM specifications:
- B-3 Soft Annealed Copper Wire.
- B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
- B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
- B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
- B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
15kV HI-DRI Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
- ANSI/ICEA S-94-649
- AEIC CS-8
- RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
EPR-PVC 15kV Grounded, Shielded Type MV90 Power Cable employs a Class B stranded copper conductor that bears ethylene propylene (EPR) rubber insulation and a polyvinyl chloride (PVC) external jacket. The Class B stranded copper conductor is made of annealed uncoated copper. Annealed copper is often preferred because the process softens the metal making it more flexible and maneuverable. The assembly includes two separate layers of an extruded semi-conducting copolymer compound that serves as a shield over the conductors and over the insulation. The extruded semi-conducting insulation shield is shielded with uncoated helically applied copper wires and then covered in 5 mil bare copper tape. The outer PVC jacket protects the conductors from extreme temperatures, chemicals, and UV rays.
TECHNICAL PARAMETER LIST
|
Phase Conductor |
Neutral |
Thickness Per Cond. (mils) |
Diameter (mils) |
Weight 1000 feet (lbs.) |
Allowable Ampacities+ |
||||||||
|
Size (AWG or kcmil) |
Strand- ing |
No. of Wires |
Size (AWG) |
Nominal Insul. |
Insul. Shield min. Point |
Approx. Jkt. |
Bare Phase Cond. |
Over Insul. |
Over Insul. Shield |
Comp. Cable |
Comp. Cable |
Direct Burial |
In Ducts |
|
ALUMINUM CONDUCTOR – 100% INSULATION LEVEL |
|||||||||||||
|
2 |
Solid |
10 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
453 |
168* |
119* |
|
2 |
7 |
10 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
470 |
168* |
119* |
|
1 |
Solid |
13 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
520 |
193* |
137* |
|
1 |
19 |
13 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
539 |
193* |
137* |
|
1/0 |
Solid |
16 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
591 |
218* |
155* |
|
1/0 |
19 |
16 |
14 |
175 |
30 |
50 |
352 |
748 |
828 |
1056 |
609 |
218* |
155* |
|
2/0 |
19 |
20 |
14 |
175 |
30 |
50 |
395 |
790 |
870 |
1098 |
703 |
248* |
177* |
|
3/0 |
19 |
25 |
14 |
175 |
30 |
50 |
443 |
838 |
918 |
1146 |
817 |
284* |
201* |
|
4/0 |
19 |
20 |
12 |
175 |
30 |
50 |
498 |
893 |
973 |
1234 |
993 |
324* |
230* |
|
250 |
37 |
16 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1213 |
360* |
257* |
|
350 |
37 |
18 |
14 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1396 |
1055 |
389** |
319** |
|
500 |
37 |
25 |
14 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1521 |
1349 |
468** |
384** |
|
750 |
61 |
24 |
12 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1798 |
1946 |
569** |
468** |
|
1000 |
61 |
20 |
10 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
1988 |
2473 |
642** |
542** |
|
1250 |
91 |
25 |
10 |
220 |
55 |
80 |
1250 |
1765 |
1895 |
2253 |
3142 |
688** |
604** |
|
1500 |
91 |
30 |
10 |
220 |
55 |
80 |
1370 |
1885 |
2015 |
2373 |
3616 |
726** |
637** |
|
COPPER CONDUCTOR – 100% INSULATION LEVEL |
|||||||||||||
|
2 |
Solid |
16 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
664 |
210* |
150* |
|
2 |
7 |
16 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
684 |
210* |
150* |
|
1 |
Solid |
20 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
780 |
240* |
171* |
|
1 |
19 |
20 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
803 |
240* |
171* |
|
1/0 |
Solid |
25 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
922 |
273* |
194* |
|
1/0 |
19 |
25 |
14 |
175 |
30 |
50 |
362 |
758 |
838 |
1066 |
951 |
273* |
194* |
|
2/0 |
19 |
20 |
12 |
175 |
30 |
50 |
405 |
800 |
880 |
1142 |
1161 |
313* |
224* |
|
3/0 |
19 |
25 |
12 |
175 |
30 |
50 |
456 |
853 |
933 |
1194 |
1390 |
358* |
255* |
|
4/0 |
19 |
20 |
10 |
175 |
30 |
50 |
512 |
908 |
988 |
1291 |
1717 |
410* |
293* |
|
250 |
37 |
24 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1992 |
446* |
322* |
|
350 |
37 |
18 |
12 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1429 |
1964 |
489** |
400** |
|
500 |
37 |
26 |
12 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1554 |
2651 |
577** |
472** |
|
750 |
61 |
25 |
10 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1840 |
3906 |
649** |
532** |
|
1000 |
61 |
26 |
9 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
2013 |
5041 |
720** |
630** |
|
1250 |
91 |
26 |
8 |
175 |
55 |
80 |
1250 |
1765 |
1895 |
2306 |
6400 |
760** |
667** |
|
+ Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 20°C ambient temperature, 90°C conductor temperature, earth RHO 90, insulation and shield RHO 400 * Full neutral construction (Ampacities assume – single phase circuit, one cable) ** 1/3 neutral cable (Ampacities assume – three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods) |
|||||||||||||
EPR-PVC 15kV Grounded, Shielded Type MV90 Power Cable is designed to carry medium voltages up to 15,000 Volts. These cables are intended for use as a feeder and can be used in many different types of applications. The cable can be installed in conduit, duct or aerial applications and must be supported by a messenger wire. This cable can also be buried directly, but only if it is installed in a system with a grounding conductor in close proximity. The cable can function in wet or dry locations and has a maximum conductor temperature of 90°C. This cable is acceptable by the Occupational Safety and Health Administration (OSHA) specifications.
We are China 15kv Primary Ud Cable Trxlp Insulation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 15kv Cable Products
15-35kv Primary Urd Concentric Neutral Aeic CS8-07 Power Cable
8.7/15 (17.5) Kv XLPE Insulated PVC Sheathed Unarmoured Power Cable
15kv133% Insulation Level Single Core Neutral Screened Cable
15kv Concentric Aluminum 2AWG Cable
15kv One Third Copper Wire Shield Trxlpe Insulation Mv90 Cable
15kv Aluminum Overhead Bundle XLPE Cable with Steel Reinforcement
Popular 15kv Trxlp Insulation Cable Products
Popular 15kv Ud Cable Products
Popular yifangcable Products
Multi Core Flexible Power Cable H07rn-F H05rn-F Cable Wire
PVC Electrical Cable Insulation Copper Aluminum Conductor PVC/PVC Termite Resistant
11 Kv 15 Kv Medium Voltage Aerial Bundled Cable 3*50+1*25mm2
6/10kv (11KV) XLPE Power Cable N2xy/Na2xy Cable 1X630mm2
Tags: 15kv Cable, 15kv Trxlp Insulation Cable, 15kv Ud Cable, yifangcable