16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC
16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC image
Get Latest Price Request a quote
- Overview
- Product Description
- Certificates
- Packing
- International Fairs
Basic Info.
Product Description
Aerial Bundled Cables
Aluminium Conductor Cables
All Aluminum Alloy Conductor (AAAC) Cables
Application
AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is
also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Standard
Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201-6 standards
Construction
AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.
This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International
Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant
standard.
Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher trength
but lower conductivity than pure aluminium.
Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind
loadings are low.
Electrical Properties
| Density@20ºC | 2.70 kg/dm |
| Temperature Coefficient@20°C | 0.00360 (°C) |
| Resistivity@20°C | 0.0326 Ohms mm²/m |
| Linear Expansivity | 23 x10-6(°C) |
Service Conditions
| Ambient Temperature | -5°C – 50°C |
| Wind Pressure | 80 – 130kg/m² |
| Seismic Acceleration | 0.12 – 0.05g |
| Isokeraunic Level | 10 – 18 |
| Relative Humidity | 5 – 100% |
Construction Parameters
BS 3242
| Code | AL Nominal Area | Cu Nominal Area Equivalent | Total Area | Stranding | Overall Diameter | Weight |
| mm² | mm² | mm² | No.×mm | mm | kg/km | |
| – | – | 6.45 | 11.7 | 7/1.47 | 4.41 | 32.2 |
| Box | – | 9.68 | 18.8 | 7/1.85 | 5.55 | 51.7 |
| Acacia | – | 12.9 | 21.9 | 7/2.08 | 6.24 | 66.1 |
| Almond | 25 | 16.1 | 30.1 | 7/2.34 | 7.02 | 82.9 |
| Ceda | 30 | 19.4 | 35.5 | 7/2.54 | 7.62 | 97.8 |
| – | 40 | 22.6 | 42.2 | 7/2.77 | 8.31 | 116.4 |
| Fir | 50 | 25.8 | 47.8 | 7/2.95 | 8.85 | 131.8 |
| Hazel | 100 | 32.3 | 59.9 | 7/3.30 | 9.9 | 165 |
| Pine | – | 38.7 | 71.7 | 7/3.61 | 10.83 | 197.7 |
| – | – | 45.2 | 84.1 | 7/3.91 | 11.73 | 231.6 |
| Willow | 150 | 48.4 | 89.8 | 7/4.04 | 12.12 | 247.5 |
| – | 175 | 51.6 | 96.5 | 7/4.19 | 12.57 | 266.2 |
| – | 300 | 58.1 | 108.8 | 7/4.45 | 13.35 | 299.8 |
| Oak | – | 64.5 | 118.9 | 7/4.65 | 13.95 | 327.8 |
| – | – | 80.6 | 118.8 | 19/2.82 | 14.1 | 327.6 |
| Mulberry | – | 96.8 | 151.1 | 19/3.18 | 15.9 | 416.7 |
| Ash | – | 113 | 180.7 | 19/3.48 | 17.4 | 498.1 |
| Elm | – | 129 | 211 | 19/3.76 | 18.8 | 582.1 |
| Poplar | – | 145 | 239 | 37/2.87 | 20.09 | 658.8 |
| – | – | 161 | 270.8 | 37/3.05 | 21.35 | 746.7 |
| Sycamore | – | 194 | 303 | 37/3.23 | 22.61 | 834.9 |
| Upas | – | 226 | 362.1 | 37/3.53 | 24.71 | 998.6 |
| – | – | 258 | 421.8 | 37/3.81 | 26.47 | 1163 |
| Yew | – | – | 479.9 | 37/4.06 | 28.42 | 1323 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
BS EN 50182
| Code | Stranding | Nominal Area | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
| No.×mm | mm² | mm | kg/km | KN | Ω/Km | A | |
| Box | 7/1.85 | 18.8 | 5.55 | 51.4 | 5.55 | 1.748 | 87 |
| Acacia | 7/2.08 | 23.8 | 6.24 | 64.9 | 7.02 | 1.3828 | 101 |
| Almond | 7/2.34 | 30.1 | 7.02 | 82.2 | 8.88 | 1.0926 | 116 |
| Cedar | 7/2.54 | 35.5 | 7.62 | 96.8 | 10.46 | 0.9273 | 129 |
| Deodar | 7/2.77 | 42.2 | 8.31 | 115.2 | 12.44 | 0.7797 | 143 |
| Fir | 7/2.95 | 47.8 | 8.85 | 130.6 | 14.11 | 0.6875 | 155 |
| Hazel | 7/3.30 | 59.9 | 9.9 | 163.4 | 17.66 | 0.5494 | 178 |
| Pine | 7/3.61 | 71.6 | 10.83 | 195.6 | 21.14 | 0.4591 | 199 |
| Holly | 7/3.91 | 84.1 | 11.73 | 229.5 | 24.79 | 0.3913 | 219 |
| Willow | 7/4.04 | 89.7 | 12.12 | 245 | 26.47 | 0.3665 | 228 |
| Oak | 7/4.65 | 118.9 | 13.95 | 324.5 | 35.07 | 0.2767 | 272 |
| Mulberry | 19/3.18 | 150.9 | 15.9 | 414.3 | 44.52 | 0.2192 | 314 |
| Ash | 19/3.48 | 180.7 | 17.4 | 496.1 | 53.31 | 0.183 | 351 |
| Elm | 19/3.76 | 211 | 18.8 | 579.2 | 62.24 | 0.1568 | 386 |
| Poplar | 37/2.87 | 239.4 | 20.09 | 659.4 | 70.61 | 0.1387 | 416 |
| Sycamore | 37/3.23 | 303.2 | 22.61 | 835.2 | 89.4 | 0.1095 | 480 |
| Upas | 37/3.53 | 362.1 | 24.71 | 997.5 | 106.82 | 0.0917 | 535 |
| Yew | 37/4.06 | 479 | 28.42 | 1319.6 | 141.31 | 0.0693 | 633 |
| Totara | 37/4.14 | 498.1 | 28.98 | 1372.1 | 146.93 | 0.0666 | 648 |
| Rubus | 61/3.50 | 586.9 | 31.5 | 1622 | 173.13 | 0.0567 | 714 |
| Sorbus | 61/3.71 | 659.4 | 33.39 | 1822.5 | 194.53 | 0.0505 | 764 |
| Araucaria | 61/4.14 | 821.1 | 37.26 | 2269.4 | 242.24 | 0.0406 | 868 |
| Redwood | 61/4.56 | 996.2 | 41.04 | 2753.2 | 293.88 | 0.0334 | 970 |
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
IEC 61089
| Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
| mm² | No.×mm | mm | kg/km | KN | Ω/Km | A | |
| 16 | 18.4 | 18.4 | 5.49 | 50.4 | 5.43 | 1.7896 | 86 |
| 25 | 28.8 | 28.8 | 6.87 | 78.7 | 8.49 | 1.1453 | 113 |
| 40 | 46 | 46 | 8.67 | 125.9 | 13.58 | 0.7158 | 151 |
| 63 | 72.5 | 72.5 | 10.89 | 198.3 | 21.39 | 0.4545 | 200 |
| 100 | 115 | 115 | 13.9 | 316.3 | 33.95 | 0.2877 | 266 |
| 125 | 144 | 144 | 15.5 | 395.4 | 42.44 | 0.2302 | 305 |
| 160 | 184 | 184 | 17.55 | 506.1 | 54.32 | 0.1798 | 355 |
| 200 | 230 | 230 | 19.65 | 632.7 | 67.91 | 0.1439 | 407 |
| 250 | 288 | 288 | 21.95 | 790.8 | 84.88 | 0.1151 | 466 |
| 315 | 363 | 363 | 24.71 | 998.9 | 106.95 | 0.0916 | 535 |
| 400 | 460 | 460 | 27.86 | 1268.4 | 135.81 | 0.0721 | 618 |
| 450 | 518 | 518 | 29.54 | 1426.9 | 152.79 | 0.0641 | 663 |
| 500 | 575 | 575 | 31.15 | 1585.5 | 169.76 | 0.0577 | 706 |
| 560 | 645 | 645 | 33.03 | 1778.4 | 190.14 | 0.0516 | 755 |
| 630 | 725 | 725 | 35.01 | 2000.7 | 213.9 | 0.0458 | 809 |
| 710 | 817 | 817 | 37.17 | 2254.8 | 241.07 | 0.0407 | 866 |
| 800 | 921 | 921 | 39.42 | 2540.6 | 271.62 | 0.0361 | 928 |
| 900* | 1036 | 1036 | 41.91 | 2861.1 | 305.58 | 0.0321 | 992 |
| 1000* | 1151 | 1151 | 44.11 | 3179 | 339.53 | 0.0289 | 1051 |
| 1120* | 1289 | 1289 | 46.75 | 3560.5 | 380.27 | 0.0258 | 1118 |
| 1250* | 1439 | 1439 | 49.39 | 3973.7 | 424.41 | 0.0231 | 1185 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
ASTM B 399/B 399M
| Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
| AWG&MCM | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
| 6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 |
| 4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 |
| 2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 |
| 0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 |
| 2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 |
| 3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 |
| 4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 |
| 250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 |
| 300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 |
| 350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 |
| 400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 |
| 450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 |
| 500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 |
| 550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 |
| 600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 |
| 650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 |
| 700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 |
| 750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 |
| 800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 |
| 900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 |
| 1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 |
| 1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 |
| 1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 |
| 1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
DIN 48201 Part 6
| Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
| Nominal | Teorical | ||||||
| mm² | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
| 16 | 15.89 | 7/1.70 | 5.1 | 43 | 4.44 | 2.0742 | 78 |
| 25 | 24.25 | 7/2.10 | 6.3 | 66 | 6.77 | 1.3593 | 102 |
| 35 | 34.36 | 7/2.50 | 7.5 | 94 | 9.6 | 0.9591 | 126 |
| 50 | 49.48 | 7/3.00 | 9 | 135 | 13.82 | 0.666 | 158 |
| 50 | 48.35 | 19/1.80 | 9 | 133 | 13.5 | 0.6849 | 156 |
| 70 | 65.81 | 19/2.10 | 10.5 | 181 | 18.38 | 0.5032 | 189 |
| 95 | 93.27 | 19/2.50 | 12.5 | 256 | 26.05 | 0.3551 | 234 |
| 120 | 116.99 | 19/2.80 | 14 | 322 | 32.68 | 0.2831 | 269 |
| 150 | 147.11 | 37/2.25 | 15.8 | 406 | 41.09 | 0.2256 | 309 |
| 185 | 181.62 | 37/2.50 | 17.5 | 500 | 50.73 | 0.1828 | 352 |
| 240 | 242.54 | 61/2.25 | 20.3 | 670 | 67.74 | 0.1371 | 420 |
| 300 | 299.43 | 61/2.50 | 22.5 | 827 | 83.63 | 0.111 | 477 |
| 400 | 400.14 | 61/2.89 | 26 | 1104 | 111.76 | 0.0831 | 568 |
| 500 | 499.83 | 61/3.23 | 29.1 | 1379 | 139.6 | 0.0665 | 649 |
| 625* | 626.2 | 91/2.96 | 32.6 | 1732 | 174.9 | 0.0531 | 742 |
| 800* | 802.09 | 91/3.35 | 36.9 | 2218 | 224.02 | 0.0415 | 857 |
| 1000* | 999.71 | 91/3.74 | 41.1 | 2767 | 279.22 | 0.0333 | 971 |
* The items marked with "*" are not in our current product range and the details are for information only.
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Technical Data
| Code | AL Nominal Area | Maximum Resistance DC at 20º | Current Rating | ||
| Temperate | Tropical | ||||
| mm² | Ω / km | Ω / 1000ft | Amp | Amp | |
| – | – | 2.87 | 0.873 | 90 | 73 |
| Box | – | 1.79 | 0.544 | 121 | 98 |
| Acacia | – | 1.4 | 0.426 | 140 | 114 |
| Almond | 25 | 1.11 | 0.339 | 162 | 131 |
| Ceda | 30 | 0.944 | 0.288 | 180 | 145 |
| – | 40 | 0.794 | 0.242 | 200 | 162 |
| Fir | 50 | 0.7 | 0.213 | 217 | 175 |
| Hazel | 100 | 0.559 | 0.17 | 250 | 201 |
| Pine | – | 0.467 | 0.142 | 279 | 224 |
| – | – | 0.398 | 0.121 | 309 | 247 |
| Willow | 150 | 0.373 | 0.114 | 322 | 258 |
| – | 175 | 0.347 | 0.106 | 337 | 270 |
| – | 300 | 0.308 | 0.0938 | 343 | 290 |
| Oak | – | 0.282 | 0.0859 | 384 | 307 |
| – | – | 0.282 | 0.086 | 385 | 307 |
| Mulberry | – | 0.222 | 0.0676 | 448 | 356 |
| Ash | – | 0.185 | 0.0565 | 501 | 398 |
| Elm | – | 0.159 | 0.048 | 553 | 438 |
| Poplar | – | 0.14 | 0.0427 | 598 | 473 |
| – | – | 0.124 | 0.0337 | 647 | 511 |
| Sycamore | – | 0.111 | 0.0377 | 694 | 547 |
| Upas | – | 0.0925 | 0.0282 | 776 | 610 |
| – | – | 0.0794 | 0.0242 | 854 | 669 |
| Yew | – | 0.0698 | 0.0213 | 925 | 723 |
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China 16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC Products
Popular 740.8mcm AAAC Flint Conductor Products
BS En 50182 Sycamore All Aluminum Alloy Conductor AAAC Wire
Acacia BS En 50182 All Aluminum Alloy Conductor AAAC
Araucaria BS En 50182 All Aluminum Alloy Conductor AAAC
BS En 50182 Elm All Aluminum Alloy Conductor AAAC Wire
6AWG ASTM B399 All Aluminum Alloy Conductor AAAC
46mm2 IEC61089 All Aluminum Alloy Conductor AAAC
Popular All Aluminium Alloy Conductor AAAC Products
500mm2 DIN 48201 All Aluminum Alloy Conductor AAAC
6AWG ASTM B399 All Aluminum Alloy Conductor AAAC
IEC 61089 All Aluminum Alloy Conductor
Araucaria BS En 50182 All Aluminum Alloy Conductor AAAC
Almond 25 mm2 Aluminum Alloy Conductor AAAC
Gnat BS En 50182 All Aluminum Conductor AAC
Popular hnbfcable Products
0.6/1kv Copper Conductor XLPE/PE Insulated Power Cable
25-100mm2 AAC AAAC ACSR Overhead Stranded Conductor ASTM DIN BS
DIN Standard 16mm2 AAAC All Aluminum Alloy Conductor
Overhead Conductor 2/0AWG Aluminum Aster AAC Conductor
240mm2 DIN Standard Bare Aluminium Alloy AAAC Conductor
All Aluminium Stranded Bare Overhead AAC Conductor
Tags: 16mm2 DIN 48201 All Aluminum Alloy Conductor AAAC, 740.8mcm AAAC Flint Conductor, All Aluminium Alloy Conductor AAAC, hnbfcable
