Basic Info.

Shape
Gyro Type

Material
ZnO

Certification
ISO9001

Brand
Haivol

Zinc Oxide Arrester
Three Pahse

Transport Package
Cartons

Specification
3-36kv 10ka

Trademark
HAIVOL

Origin
China

HS Code
8535400000

Production Capacity
60, 000PCS/Month

Product Description

Surge Arrester Series

General 

1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite) 

2. Application:for protection of power transmission & distribution system from over-voltage. 

3. Features: 

 

1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.

2)Easy installation and maintenance. 

3)Good sealing capability to ensure reliable operation.

4)Protection and reliability of the surge arrester have been greatly enhanced.

Working Condition

1. Ambient air temperature:-40ºC ~+40ºC ; 

2. Altitude:<=2000m; 

3. Frequency: 48Hz~62Hz; 

4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter; 

5. Earthquake intensity is less than 8 degree; 

6. Max. Wind speed is 35m/s.

Main Techical Parameter

1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-5W-6 6 5.1 18   320 150 65
YH-5W-9 9 7.65 27   430 150 65
YH-5W-12 12 10.2 36   430 150 65
YH-5W-15 15 12.75 45   530 150 65
YH-5W-18 18

15.3

54   530 150 65
YH-5W-21 21 16.8 63   640 150 65
YH-5W-24 24 19.2 72   640 150 65
YH-5W-27 27 21.6 81   740 150 65
YH-5W-30 30 24 90   890 150 65
YH-5W-33 33 26.4 99   890 150 65
YH-5W-36 36 28.8 108   1115 150 65

2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-10W-6 6 5.1 18 1 320 250 100
YH-10W-9 9 7.65 27 1 430 250 100
YH-10W-12 12 10.2 36 1 430 250 100
YH-10W-15 15 12.75 45 1 530 250 100
YH-10W-18 18 15.3 54 1 530 250 100
YH-10W-21 21 16.8 63 1 640 250 100
YH-10W-24 24 19.2 72 1 740 250 100
YH-10W-27 27 21.6 81 1 740 250 100
YH-10W-30 30 24 90 1 890 250 100
YH-10W-33 33 26.4 99 1 890 250 100
YH-10W-36 36 28.8 108 1 1115 250 100
YH-10W-42 42 33.6 126 2 1260 400 100
YH-10W-48 48 39 139 2 1260 400 100
YH-10W-54 54 42 160 2 1260 400 100
YH-10W-60 60 48 178 2 1465 400 100
YH-10W-66 66 52.8 196 2 1465 400 100
YH-10W-72 72 57 214 2 2255 400 100
YH-10W-84 84 67.2 244 2 2255 400 100
YH-10W-90 90 72.5 249 2 2255 400 100
YH-10W-96 96 75 265 3 3555 800 100
YH-10W-108 108 84 281 3 3555 800 100
YH-10W-120 120 96 300 3 4153 800 100
YH-10W-150 150 120 416 3 5040 800 100
YH-10W-200 200 156 520 3 7110 800 100

3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-20W-108 108 84 281 3 3555 800 100
YH-20W-120 120 96 300 3 4153 800 100
YH-20W-150 150 120 416 3 5040 800 100
YH-20W-200 200 156 520 3 7110 800 100

4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y5W-6 6 5.1 18   280 150 65
Y5W-9 9 7.65 27   320 150 65
Y5W-12 12 10.2 36   320 150 65
Y5W-15 15 12.75 45   450 150 65
Y5W-18 18

15.3

54   450 150 65
Y5W-21 21 16.8 63   450 150 65
Y5W-24 24 19.2 72   510 150 65
Y5W-27 27 21.6 81   510 150 65
Y5W-30 30 24 90   890 150 65
Y5W-33 33 26.4 99   890 150 65
Y5W-36 36 28.8 108   890 150 65

5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y10W-6 6 5.1 18 1 280 250 100
Y10W-9 9 7.65 27 1 320 250 100
Y10W-12 12 10.2 36 1 320 250 100
Y10W-15 15 12.75 45 1 450 250 100
Y10W-18 18 15.3 54 1 450 250 100
Y10W-21 21 16.8 63 1 450 250 100
Y10W-24 24 19.2 72 1 510 250 100
Y10W-27 27 21.6 81 1 510 250 100
Y10W-30 30 24 90 1 890 250 100
Y10W-33 33 26.4 99 1 890 250 100
Y10W-36 36 28.8 108 1 890 250 100
Y10W-42 42 33.6 126 2 1256 400 100
Y10W-48 48 39 139 2 1256 400 100
Y10W-54 54 42 160 2 1256 400 100
Y10W-60 60 48 178 2 1440 400 100
Y10W-66 66 52.8 196 2 1440 400 100
Y10W-72 72 57 214 2 1440 400 100
Y10W-84 84 67.2 244 2 2200 400 100
Y10W-90 90 72.5 249 2 2200 400 100
Y10W-96 96 75 265 3 3350 800 100
Y10W-108 108 84 281 3 3350 800 100
Y10W-120 120 96 300 3 3948 800 100
Y10W-150 150 120 416 3 4400 800 100
Y10W-200 200 156 520 3 6700 800 100

6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y20W-108 108 84 281 3 3555 800 100
Y20W-120 120 96 300 3 4106 800 100
Y20W-150 150 120 416 3 4400 800 100
Y20W-200 200 156 520 3 6700 800 100
Y20W-444 444 324 1106 4 17052 2000 100

Note: For details, please refer to the catalogue.
Participate in the exhibition pictures

testing report

 

We are China 18kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 18kv Lightning Arrester Products

18kv High Quality Lightning Arrester for Distribution Line

18kv Metal Oxide Lightning Arrester for Overvoltage Protection

18kv High Voltage Lightning Arrester for Distribution Line

L&R 18kv 10ka Zinc Oxide Varistor Polymer Housed Type Surge Arrester

Popular Lightning Arrester Products

60kv High Voltage Electrical Lightning Arrester for Transmission Line

27-30kv Polymer Silicon Surge Arrester, Lightning Arrester, Surge Suppressor

21kv Metal Oxide Lightning Arrester for Overvoltage Protection

Low Voltage 12V 12kv Moa Surge Lightning Arrester

Clevis, Ball "Y " Type - 9 3 1/2

Cut out 11kv Mount & Carrier

Popular metal oxide lightning arrester Products

42kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester

21kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester

9kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester

33kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester

33kv Porcelain Surge Arrester Lightning Arrester

Kema Silicone Housed Series Medium Voltage Zinc-Oxide Lightning Arrester (YH10W5-9)

Popular people Products

Gw9-15g High Voltage Isolation Switch

38kv High Quality Breaking Capacity Fuse Cutout

9kv Metal Oxide Surge Protector Arrester for Outdoor

30kv High Voltage Polymer Insulator for Substation

11kv Cutout Switch with Disconnect Blade for Distribution Line

Ring Connectors/Insulation Piercing Multi-Core Branch Connectors Jch

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION