Quick Details

2021 Hot Selling BS Standard Bare AAC AAAC Aluminium Conductor

LJ/LGJ

ISO9001, CE, SABS

None

Aluminum

Overhead

Stranded

Bare

2000ton/Month

SABS, ISO9001-2008, CQC Certificate, CE, SGS

Accord with The Request

1km

L/C, D/P, D/a, T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

JIAPU

Wooden Drum

AAC

Henan China

7614900000

Product Details

2021 Hot selling BS standard Bare AAC AAAC Aluminium Conductor

(1). All aluminium conductor (AAC)
(2). All aluminimum alloy conductor(AAAC)
(3). Aluminum conductor steel reinforced (ACSR)
(4). Anti-corrosion type ACSR
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

BS EN 50182
Code Stranding Nominal Area Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
  No.×mm mm^2 mm kg/km KN Ω/Km A
Box 7/1.85 18.8 5.55 51.4 5.55 1.748 87
Acacia 7/2.08 23.8 6.24 64.9 7.02 1.3828 101
Almond 7/2.34 30.1 7.02 82.2 8.88 1.0926 116
Cedar 7/2.54 35.5 7.62 96.8 10.46 0.9273 129
Deodar 7/2.77 42.2 8.31 115.2 12.44 0.7797 143
Fir 7/2.95 47.8 8.85 130.6 14.11 0.6875 155
Hazel 7/3.30 59.9 9.9 163.4 17.66 0.5494 178
Pine 7/3.61 71.6 10.83 195.6 21.14 0.4591 199
Holly 7/3.91 84.1 11.73 229.5 24.79 0.3913 219
Willow 7/4.04 89.7 12.12 245 26.47 0.3665 228
Oak 7/4.65 118.9 13.95 324.5 35.07 0.2767 272
Mulberry 19/3.18 150.9 15.9 414.3 44.52 0.2192 314
Ash 19/3.48 180.7 17.4 496.1 53.31 0.183 351
Elm 19/3.76 211 18.8 579.2 62.24 0.1568 386
Poplar 37/2.87 239.4 20.09 659.4 70.61 0.1387 416
Sycamore 37/3.23 303.2 22.61 835.2 89.4 0.1095 480
Upas 37/3.53 362.1 24.71 997.5 106.82 0.0917 535
Yew 37/4.06 479 28.42 1319.6 141.31 0.0693 633
Totara 37/4.14 498.1 28.98 1372.1 146.93 0.0666 648
Rubus 61/3.50 586.9 31.5 1622 173.13 0.0567 714
Sorbus 61/3.71 659.4 33.39 1822.5 194.53 0.0505 764
Araucaria 61/4.14 821.1 37.26 2269.4 242.24 0.0406 868
Redwood 61/4.56 996.2 41.04 2753.2 293.88 0.0334 970
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

IEC 61089
Code Nominal Area Stranding Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
mm^2 No.×mm mm kg/km KN Ω/Km A
16 18.4 18.4 5.49 50.4 5.43 1.7896 86
25 28.8 28.8 6.87 78.7 8.49 1.1453 113
40 46 46 8.67 125.9 13.58 0.7158 151
63 72.5 72.5 10.89 198.3 21.39 0.4545 200
100 115 115 13.9 316.3 33.95 0.2877 266
125 144 144 15.5 395.4 42.44 0.2302 305
160 184 184 17.55 506.1 54.32 0.1798 355
200 230 230 19.65 632.7 67.91 0.1439 407
250 288 288 21.95 790.8 84.88 0.1151 466
315 363 363 24.71 998.9 106.95 0.0916 535
400 460 460 27.86 1268.4 135.81 0.0721 618
450 518 518 29.54 1426.9 152.79 0.0641 663
500 575 575 31.15 1585.5 169.76 0.0577 706
560 645 645 33.03 1778.4 190.14 0.0516 755
630 725 725 35.01 2000.7 213.9 0.0458 809
710 817 817 37.17 2254.8 241.07 0.0407 866
800 921 921 39.42 2540.6 271.62 0.0361 928
900* 1036 1036 41.91 2861.1 305.58 0.0321 992
1000* 1151 1151 44.11 3179 339.53 0.0289 1051
1120* 1289 1289 46.75 3560.5 380.27 0.0258 1118
1250* 1439 1439 49.39 3973.7 424.41 0.0231 1185
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

ASTM B 399/B 399M
Nominal Area Stranding Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
AWG&MCM mm^2 No.×mm mm kg/km KN Ω/Km A
6 13.2 7/1.55 4.65 36.2 4.18 2.5361 69
4 21.1 7/1.96 5.88 57.9 6.69 1.586 93
2 33.5 7/2.47 7.41 92 10.6 0.9987 123
0 53.5 7/3.12 9.36 146.8 17 0.62592 165
2/0 67.3 7/3.50 10.5 184.8 20.4 0.49738 190
3/0 84.9 7/3.93 11.79 233 25.7 0.3945 219
4/0 107 7/4.42 13.26 294.7 32.5 0.31188 253
250 126 19/2.91 14.55 346.7 38.8 0.26509 280
300 152 19/3.19 15.95 416.7 46.6 0.22059 313
350 178 19/3.45 17.25 487.3 52 0.1886 345
400 203 19/3.69 18.45 557.5 59.5 0.16486 375
450 228 19/3.91 19.55 626 66.8 0.14683 402
500 253 19/4.12 20.6 695 74.2 0.13224 429
550 279 37/3.10 21.7 766.2 83.9 0.11995 455
600 303 37/3.23 22.61 831.9 91 0.11049 478
650 330 37/3.37 23.59 905.5 94.9 0.1015 504
700 354 37/3.49 24.43 971.2 101 0.09464 525
750 381 37/3.62 25.34 1045 109 0.08796 549
800 404 37/3.73 26.11 1109 116 0.08285 569
900 456 37/3.96 27.72 1250 131 0.07351 612
1000 508 37/4.18 29.26 1393 146 0.06597 653
1250 631 61/3.63 32.67 1732 179 0.05306 743
1500 759 61/3.98 35.82 2082 215 0.04414 827
1750 886 61/4.30 38.7 2431 251 0.03781 904
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

DIN 48201 Part 6
Nominal Area Stranding Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
Nominal Teorical
mm^2 mm^2 No.×mm mm kg/km KN Ω/Km A
16 15.89 7/1.70 5.1 43 4.44 2.0742 78
25 24.25 7/2.10 6.3 66 6.77 1.3593 102
35 34.36 7/2.50 7.5 94 9.6 0.9591 126
50 49.48 7/3.00 9 135 13.82 0.666 158
50 48.35 19/1.80 9 133 13.5 0.6849 156
70 65.81 19/2.10 10.5 181 18.38 0.5032 189
95 93.27 19/2.50 12.5 256 26.05 0.3551 234
120 116.99 19/2.80 14 322 32.68 0.2831 269
150 147.11 37/2.25 15.8 406 41.09 0.2256 309
185 181.62 37/2.50 17.5 500 50.73 0.1828 352
240 242.54 61/2.25 20.3 670 67.74 0.1371 420
300 299.43 61/2.50 22.5 827 83.63 0.111 477
400 400.14 61/2.89 26 1104 111.76 0.0831 568
500 499.83 61/3.23 29.1 1379 139.6 0.0665 649
625* 626.2 91/2.96 32.6 1732 174.9 0.0531 742
800* 802.09 91/3.35 36.9 2218 224.02 0.0415 857
1000* 999.71 91/3.74 41.1 2767 279.22 0.0333 971

 

AAAC– ASTM B399 standard
Area No./wire diameter Overall diameter Weight Nominal breaking load Max D.C. resistance at 20ºC Standard length
Nominal Actual
AWG or MCM mm2 mm mm Kg/km KN Ω//km m±5%
6 13.3 7/1.554 4.67 37 4.22 2.5199 3500
4 21.15 7/1.961 5.89 58 6.71 1.5824 3000
2 33.63 7/2.474 7.42 93 10.68 0.9942 2500
1/0 53.48 7/3.119 9.36 148 16.97 0.6256 2000
2/0 67.42 7/3.503 10.51 186 20.52 0.4959 3500
3/0 85.03 7/3.932 11.8 234 25.86 0.3939 3000
4/0 107.23 7/4.417 13.26 296 32.63 0.3119 2000
250 126.66 19/2.913 14.57 349 38.93 0.2642 2000
300 152.1 19/3.193 15.97 419 46.77 0.2199 3000
350 177.35 19/3.447 17.24 489 52.25 0.1887 3000
400 202.71 19/3.686 18.43 559 59.74 0.165 2500
450 228 19/3.909 19.66 629 67.19 0.1467 2000
500 253.35 19/4.120 20.6 698 74.64 0.1321 2000
550 278.6 37/3.096 21.67 768 83.8 0.1202 2000
600 303.8 37/3.233 22.63 838 91.38 0.1102 2000
650 329.25 37/3.366 23.56 908 97.94 0.1016 2000
700 354.55 37/3.493 24.45 978 102.2 0.0944 3500
750 380.2 37/3.617 25.32 1049 109.6 0.088 3000
800 405.15 37/3.734 26.14 1117 116.8 0.0826 3000
900 456.16 37/3.962 27.73 1258 131.5 0.0733 3000
1000 506.71 37/4.176 29.23 1399 146.1 0.066 2500
 

Workshop:

Shipment:

Certification:

FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China 

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS

 4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc 

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request. 

7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.

 

We are China 2021 Hot Selling BS Standard Bare AAC AAAC Aluminium Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Aluminium Products

Power Fittings Aluminium Suspension Clamp Xgh-4

XLPE Insulated Aluminium Aerial Bundle Cable

Power Fittings Aluminium Suspension Clamp Xgh-3A

Mill Finish Polished 1.8-8mm Silver Mirror Aluminium Mirror Sheet

6061 6083 T6 Aluminum/Aluminium Alloy Plate/Sheet

ACSR Conductor (Aluminum Conductor Steel Reinforced) Drake

Popular Aluminium Conductor Products

Typical Distribution Mv Load Break Fuse Cutout with Arc Chute

ABC/XLPE Insulated PE/PVC Sheathed Sta Armoured Electrical Wire/Control Power Cable

AAC Bare Conductor Transmission Line

Pulling Clamp with Pulley for ACSR 120‘ 20 mm2 Conductor

Aluminium Conductor Steel Reinforced, Overhead Bare ACSR Conductors with ASTM BS IEC Standard.

LV Fuse Cutouts

Popular Conductor Products

ACSR Aluminum Conductor Steel Reinforced

AAAC Conductor Aluminum Alloy Conductor ASTM B399

Cable AAC Aluminum Conductor Bare Conductor

ACSR Conductor Over Head Line Sparrow

Good Quality 0.6/1kv ASTM Standard AAC AAAC ACSR Conductor

ASTM Standard Aluminum Conductor Steel Reinforced ACSR Conductor

Popular jpcable99 Products

Copper 12/20 (24) Kv XLPE Insualted/ PVC Sheath Ug Cable

European Standard XLPE Insulated Power Cable

Cu/XLPE/Swa/PVC Power Cable

Acar with IEC61089 Standard

630mm2 Aluminium Alloy Bare Conductor

1-35kv XLPE Insulated Armoured Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION