27kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

China 
                27kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps
              manufacture and supplier

27kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps image

Get Latest Price Request a quote

Basic Info.

Shape
Gyro Type

Material
ZnO

Certification
ISO9001

Zinc Oxide Arrester
Three Pahse

Transport Package
Cartons

Specification
3-36kv 10ka

Trademark
HAIVOL

Origin
China

HS Code
8535400000

Production Capacity
60, 000PCS/Month

Product Description

Surge Arrester Series

General 

1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite) 

2. Application:for protection of power transmission & distribution system from over-voltage. 

3. Features: 

 

1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.

2)Easy installation and maintenance. 

3)Good sealing capability to ensure reliable operation.

4)Protection and reliability of the surge arrester have been greatly enhanced.

Working Condition

1. Ambient air temperature:-40ºC ~+40ºC ; 

2. Altitude:<=2000m; 

3. Frequency: 48Hz~62Hz; 

4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter; 

5. Earthquake intensity is less than 8 degree; 

6. Max. Wind speed is 35m/s.

Main Techical Parameter

1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-5W-6 6 5.1 18   320 150 65
YH-5W-9 9 7.65 27   430 150 65
YH-5W-12 12 10.2 36   430 150 65
YH-5W-15 15 12.75 45   530 150 65
YH-5W-18 18

15.3

54   530 150 65
YH-5W-21 21 16.8 63   640 150 65
YH-5W-24 24 19.2 72   640 150 65
YH-5W-27 27 21.6 81   740 150 65
YH-5W-30 30 24 90   890 150 65
YH-5W-33 33 26.4 99   890 150 65
YH-5W-36 36 28.8 108   1115 150 65

2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-10W-6 6 5.1 18 1 320 250 100
YH-10W-9 9 7.65 27 1 430 250 100
YH-10W-12 12 10.2 36 1 430 250 100
YH-10W-15 15 12.75 45 1 530 250 100
YH-10W-18 18 15.3 54 1 530 250 100
YH-10W-21 21 16.8 63 1 640 250 100
YH-10W-24 24 19.2 72 1 740 250 100
YH-10W-27 27 21.6 81 1 740 250 100
YH-10W-30 30 24 90 1 890 250 100
YH-10W-33 33 26.4 99 1 890 250 100
YH-10W-36 36 28.8 108 1 1115 250 100
YH-10W-42 42 33.6 126 2 1260 400 100
YH-10W-48 48 39 139 2 1260 400 100
YH-10W-54 54 42 160 2 1260 400 100
YH-10W-60 60 48 178 2 1465 400 100
YH-10W-66 66 52.8 196 2 1465 400 100
YH-10W-72 72 57 214 2 2255 400 100
YH-10W-84 84 67.2 244 2 2255 400 100
YH-10W-90 90 72.5 249 2 2255 400 100
YH-10W-96 96 75 265 3 3555 800 100
YH-10W-108 108 84 281 3 3555 800 100
YH-10W-120 120 96 300 3 4153 800 100
YH-10W-150 150 120 416 3 5040 800 100
YH-10W-200 200 156 520 3 7110 800 100

3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
YH-20W-108 108 84 281 3 3555 800 100
YH-20W-120 120 96 300 3 4153 800 100
YH-20W-150 150 120 416 3 5040 800 100
YH-20W-200 200 156 520 3 7110 800 100

4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y5W-6 6 5.1 18   280 150 65
Y5W-9 9 7.65 27   320 150 65
Y5W-12 12 10.2 36   320 150 65
Y5W-15 15 12.75 45   450 150 65
Y5W-18 18

15.3

54   450 150 65
Y5W-21 21 16.8 63   450 150 65
Y5W-24 24 19.2 72   510 150 65
Y5W-27 27 21.6 81   510 150 65
Y5W-30 30 24 90   890 150 65
Y5W-33 33 26.4 99   890 150 65
Y5W-36 36 28.8 108   890 150 65

5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

 

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y10W-6 6 5.1 18 1 280 250 100
Y10W-9 9 7.65 27 1 320 250 100
Y10W-12 12 10.2 36 1 320 250 100
Y10W-15 15 12.75 45 1 450 250 100
Y10W-18 18 15.3 54 1 450 250 100
Y10W-21 21 16.8 63 1 450 250 100
Y10W-24 24 19.2 72 1 510 250 100
Y10W-27 27 21.6 81 1 510 250 100
Y10W-30 30 24 90 1 890 250 100
Y10W-33 33 26.4 99 1 890 250 100
Y10W-36 36 28.8 108 1 890 250 100
Y10W-42 42 33.6 126 2 1256 400 100
Y10W-48 48 39 139 2 1256 400 100
Y10W-54 54 42 160 2 1256 400 100
Y10W-60 60 48 178 2 1440 400 100
Y10W-66 66 52.8 196 2 1440 400 100
Y10W-72 72 57 214 2 1440 400 100
Y10W-84 84 67.2 244 2 2200 400 100
Y10W-90 90 72.5 249 2 2200 400 100
Y10W-96 96 75 265 3 3350 800 100
Y10W-108 108 84 281 3 3350 800 100
Y10W-120 120 96 300 3 3948 800 100
Y10W-150 150 120 416 3 4400 800 100
Y10W-200 200 156 520 3 6700 800 100

6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

Model Rated voltage (kVr.m.s) Continuous operating Voltage(KVr.m.s) Lightening impulse residual voltage under nominal discharge current (<=KVp) Line discharge class Creepage distance(mm) 2ms square wave impulse current withstands(A) 4/10μhigh current impulse Withstands(KAp)
Y20W-108 108 84 281 3 3555 800 100
Y20W-120 120 96 300 3 4106 800 100
Y20W-150 150 120 416 3 4400 800 100
Y20W-200 200 156 520 3 6700 800 100
Y20W-444 444 324 1106 4 17052 2000 100

Note: For details, please refer to the catalogue.
Participate in the exhibition pictures

testing report

 

We are China 27kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Metal-Oxide Surge Arrester Products

24kv Silicone Polymer Housing Composite Metal Oxide Surge Arrester

21kv 5ka Silicon Rubber Lightning Arrester

18kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

(YH5W-11) Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

21kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

9kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

Popular people Products

12kv High Quality Polymer Fuse Cutout for Overhead Line

High Voltage Strain Porcelain Insulators

15kv Fuse Cutout Approved by Kema Laboratory

18kv Porcelain Fuse Link Fuse Cutout for Overhead Line

84kv Metal Oxide Lightning Arrester for Overvoltage Protection

24kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester

Popular Polymeric Housed Surge Arrester Products

33kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

18kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

15kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

9kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

Supply Polymeric Housed Surge Arrester

12kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps

Popular Surge Arrester Products

Electric Lightning Low Voltage Surge Arrester

Terminal, Aluminium Compression-Cableto Flat-4 Hole: Ccls 684c

15kv High Voltage Surge Arrester for Distribution Line

Surge Arrester With Disconnector 200-216KV

Polymer Fuse Cutout, Drop out Fuses 3kv 200A

24kv Best Price LED Street Light Surge Arrester

Tags: , , ,