3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant
3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant image
Get Latest Price Request a quote
Quick Details
Product Details
Description
The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC,
which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform
to IEC60502.
Construction
- Conductor:
a) Phase – The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b) Neutral or messenger – The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted
circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted
circular stranded..
- Insulation:
The phase, neutral conductors shall be extruded with XLPE as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20ºC | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30ºC | |||||||||
Conductor temperature=75ºC | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20ºC | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20ºC | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
STANDARD NF C 33-209
NFA 2X
Phases | Neutral/Messenger | ||||||||
Distribution Lines | Pub. Lighting | ||||||||
Cable Type | Number of | Number of | Avarage | Resistance | Number of | Conductance | Avarage | Rated | Resistance |
core | wire | diameter | at 20ºC | core | at 30ºC | diameter | Strength | at 20ºC | |
mm² | mm² | PCS | mm | ohm/km | mm² | A | mm | kN | ohm/km |
2×16 | 2×16 | 7 | 4.6 | 1.91 | – | – | – | – | – |
2×35 | 2×35 | 7 | 5.9 | 1.20 | – | – | – | – | – |
2×35 | 2×35 | 7 | 6.9 | 0.868 | – | – | – | – | – |
2×50 | 2×50 | 7 | 8.1 | 0.641 | – | – | – | – | – |
4×16 | 4×16 | 7 | 4.6 | 1.91 | – | – | – | – | – |
4×25 | 4×25 | 7 | 5.9 | 1.20 | – | – | – | – | – |
4×35 | 4×35 | 7 | 6.9 | 0.868 | – | – | – | – | – |
3×25+54.6 | 3×25 | 7 | 5.9 | 1.20 | – | – | 9.6 | 16.0 | 0.63 |
3×25+1×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 1×16 | 60 | 9.6 | 16.0 | 0.63 |
3×25+2×16+54.6 | 3×25 | 7 | 5.9 | 1.20 | 2×16 | 9.6 | 16.0 | 0.63 | |
3×35+54.6 | 3×35 | 7 | 6.9 | 0.868 | – | – | 9.6 | 16.0 | 0.63 |
3×35+1×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 1×16 | 60 | 9.6 | 16.0 | 0.63 |
3×35+2×16+54.6 | 3×35 | 7 | 6.9 | 0.868 | 2×16 | 9.6 | 16.0 | 0.63 | |
3×50+54.6 | 3×50 | 7 | 8.1 | 0.641 | – | – | 9.6 | 16.0 | 0.63 |
3×50+1×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 1×16 | 60 | 9.6 | 16.0 | 0.63 |
3×50+2×16+54.6 | 3×50 | 7 | 8.1 | 0.641 | 2×16 | 9.6 | 16.0 | 0.63 | |
3×70+54.6 | 3×70 | 12 | 9.7 | 0.443 | – | – | 9.6 | 16.0 | 0.63 |
3×70+1×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 1×16 | 60 | 9.6 | 16.0 | 0.63 |
3×70+2×16+54.6 | 3×70 | 12 | 9.7 | 0.443 | 2×16 | 9.6 | 16.0 | 0.63 | |
3×70+1×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 1×25 | 9.6 | 16.0 | 0.63 | |
3×70+2×25+54.6 | 3×70 | 12 | 9.7 | 0.443 | 2×25 | 9.6 | 16.0 | 0.50 | |
3×70+70 | 3×70 | 12 | 9.7 | 0.443 | – | – | 10.2 | 20.6 | 0.50 |
3×70+1×16+70 | 3×70 | 12 | 9.7 | 0.443 | 1×16 | 60 | 10.2 | 20.6 | 0.50 |
3×70+2×16+70 | 3×70 | 12 | 9.7 | 0.443 | 2×16 | 10.2 | 20.6 | 0.50 | |
3×95+70 | 3×95 | 12 | 11.5 | 0.320 | – | – | 10.2 | 20.6 | 0.50 |
3×95+1×16+70 | 3×95 | 12 | 11.5 | 0.320 | 1×16 | 60 | 10.2 | 20.6 | 0.50 |
3×95+2×16+70 | 3×95 | 12 | 11.5 | 0.320 | 2×16 | 10.2 | 20.6 | 0.50 | |
3×120+70 | 3×120 | 12 | 12.8 | 0.253 | – | – | 10.2 | 20.6 | 0.50 |
3×120+1×16+70 | 3×120 | 19 | 12.8 | 0.253 | 1×16 | 10.2 | 20.6 | 0.50 | |
3×120+2×16+70 | 3×120 | 19 | 12.8 | 0.253 | 2×16 | 60 | 10.2 | 20.6 | 0.50 |
3×150+70 | 3×150 | 19 | 14.5 | 0.206 | – | 10.2 | 20.6 | 0.50 | |
3×150+1×16+70 | 3×150 | 19 | 14.5 | 0.206 | 1×16 | – | 10.2 | 20.6 | 0.50 |
3×150+2×16+70 | 3×150 | 19 | 14.5 | 0.206 | 2×16 | 60 | 10.2 | 20.6 | 0.50 |
3×120+95 | 3×120 | 19 | 12.8 | 0.253 | – | 12.9 | 27.9 | 0.343 | |
3×120+1×16+95 | 3×120 | 19 | 12.8 | 0.253 | 1×16 | – | 12.9 | 27.9 | 0.343 |
3×120+2×16+95 | 3×120 | 19 | 12.8 | 0.253 | 2×16 | 60 | 12.9 | 27.9 | 0.343 |
3×150+95 | 3×150 | 19 | 14.5 | 0.206 | – | 12.9 | 27.9 | 0.343 | |
3×150+1×16+95 | 3×150 | 19 | 14.5 | 0.206 | 1×16 | – | 12.9 | 27.9 | 0.343 |
3×150+2×16+95 | 3×150 | 19 | 14.5 | 0.206 | 2×16 | 60 | 12.9 | 27.9 | 0.343 |
Till now, TDDL has obtained a series of certifications covering ISO9001 quality management, ISO14001 environmental ,
management system certification, OHSAS18001 occupational health and safety management system, China CCC, PCCC,
CRCC, CE etc.
Henan Tong-da Cable Co., Ltd, successfully listed on Shenzhen Stock Exchange on Mar.3rd, 2011 (Stock Abbreviation:
Tongda Stock, Stock Code: 002560), has devoted itself to the production, R & D and sales of wires and cables for more than
30 years.
of major professional products: Phase and earth conductor, power cable, overhead insulated cable, fire resistant cable, enviro
nmental protection PVC insulated building wire, contact and catenary wire for Electrified Railway, cable for rail traffic and control
cable. Not only special wires and cables in flame retardant, fire resistant, low-smoke free halogen, irradiation cross-linking and
etc. can be produced simultaneously, but also can meet the standard of IEC, British BS, American ASTM, German DIN and
others,on the basis of customers’ requirements.
occupational health system certification, CCC National Product Certification, PCCC product certification, CRCC railway product
certification, and obtained the National Industrial Product Production License, AAA credit rating certificate, etc.
Grid Corporation, China Railway Corporation and many large well-known real estate companies, Tong-da’s products, widely
usedin smart grid, electrified railway, urban rail traffic, real estate engineering, home decoration, have exported to more than
60 countries and regions, such as Europe, Middle East, Southeast Asia, Africa and highly received unanimous praise from
numerous customers.
Customer visit
The company exports to South America, Southeast Asia, the Middle East, Europe, North America, Africa and more than 60
countries and regions, and enjoys a certain reputation among users.
Explanation
The package is usually wooden drums ,steel drums,steel-wooden drums or according to customers’ requirement.
Q1. Are you a manufacturer?
Yes, we are a manufacturer own factory with almost 30 years experiences.
Q2. What are your main products?
Main products including: ACSR, AAC, AAAC ,ACAR,ACSS,ACSS/TW,ACCC,ACSR/AW,ACS ,GSW, Aerial Bundled Cable
(Low/Medium Voltage),Power Cable,Copper Alloy Wire for Electrical Railway System
Q3. Which countries and regions have your products been exported to ?
Asia, South America, North America, Europe, Africa, Oceania,including: Peru,Colombia, Chile,Korea, America, Philippines,
Vietnam,Singapore, Australia,Dominica,Kenya,Poland,Pakistan,Rwanda,Brazil,Myanmar,Zambia, Congo,Ecuador,Lesotho,
Bolivia,Thailand ,Germany,Angola,Yemen,India,Netherlands,Benin,Maldives,Canada,Honduras,Albania,Burundi,Paraguay ,
Sri Lanka,New Zealand,Bahrain,Costa Rica,Trinidad and Tobago,Guyana, Nicaragua,Mongolia,Haiti,Ghana,Macedonia etc.
Q4. Is the quality of your products guaranteed?
Yes,the quality of our products is highly guaranteed. The products are ISO 9001 ,ISO 14001,OHSAS 18001 certificated. Our
workshops are equipped with advanced production and inspection equipment and the products strictly according to internati
onal standards or customers’ requirements. We do 100% inspection for every batch of semi-finished and finished products.
Q5. What’s the package of products ?
The package is usually wooden drums ,steel drums,steel-wooden drums or according to customers’ requirement.
Q6. How can I get samples?
Please notify the detailed information of sample you need. If we don’t have the exact model, please consider whether the sim
ilar model is OK for you. we provide the free samples for inspection while freight is charged.
Q7. What is our payment terms ?
We can accept the following payment terms: T/T, L/C, O/A
We are China 3 Phase Conductor Aerial Bundled Cable 5 Core Excellent Corrosion Resistant manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1 Kv PE Insulated Cable Products
Outdoor Customized Aerial Bundled Cables Environmental Protection
PVC Insulated Aerial Electrical Cable with 0.6/1 Kv AAC Conductors Triplex Service Drop Cable
Polyethylene Insulation 4 Core Aerial Bundled Cables 0.6kv / 1kv for Overhead Power Line
1 Kv PE Insulated Aerial Bunch Cable 5 Cores with Neutral Conductor IEC 60502
Popular Street Lighting Conductor Products
PVC Insulated Aerial Electrical Cable with 0.6/1 Kv AAC Conductors Triplex Service Drop Cable
Aerial Bundled XLPE Insulation Cable Aerial Power Cable with 1 Messenger Conductor
Electrical Insulated Aerial Bundled Cable Without Street Lighting Conductor
1 Kv PE Insulated Aerial Bunch Cable 5 Cores with Neutral Conductor IEC 60502
Polyethylene Insulation 4 Core Aerial Bundled Cables 0.6kv / 1kv for Overhead Power Line
Outdoor Customized Aerial Bundled Cables Environmental Protection
Popular tongdacable Products
Medium Voltage XLPE Power Cable
H03VV-F 3182-Y 5 Core X0.75sqmm to 10sqmm BS En 50525-2-11 Electrical Cable Wire
Flexible Mobile Shielding Rubber Sheathed Cable
XLPE Insulated PVC Sheath 185 Sq mm Electrical Cable LV There Core Armoured Power Cable
Medium Voltage Aluminum Conductor Steel Wire Armored XLPE Insulation Electrical Cable
XLPE / PVC Insulation PVC Sheath Armoured Electrical Cable / Underground Low Voltage Cable
Popular Triplex Service Drop Cable Products
Duplex Triplex Quadruplex Al XLPE Icea S -76-474 Standard Service Drop Cable
Aluminum Conductor XLPE Insulated Low Voltage Triplex Service Drop Cable
Triplex Service Drop 3 Core ABC Cable
Overhead Bundled Cable ABC, Low Voltage 0.6/1kv Insulated Cable
0.6/1kv Service Drop Cable 3X2AWG+2AWG
Tags: 1 Kv PE Insulated Cable, Street Lighting Conductor, tongdacable, Triplex Service Drop Cable