300 mm2 XLPE Low Voltage Power Cable
300 mm2 XLPE Low Voltage Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Low Price China Factory Manufacture 300mm2 xlpe cable Low Voltage XLPE Power Cable
Product Description
Product Description Of Low Voltage XLPE Power Cable
Product standard:
GB/T12706.1-2008
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90ºC; and is 250 ºC when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D ("D" refers to cable diameter)
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | – | ≤12.1 | – | 3.5 | 20 | – | 27 | – |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+1×2.5 | 0.7 | 1.5 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+1×4 | 0.7 | 1.5 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+1×6 | 0.7 | 1.5 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+2×2.5 | 0.7 | 1.5 | 13.9 | 309 | 202 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+2×4 | 0.7 | 1.5 | 15.3 | 413 | 219 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+2×6 | 0.7 | 1.5 | 18.2 | 603 | 338 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4+1×2.5 | 0.7 | 1.5 | 14.5 | 331 | 214 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6+1×4 | 0.7 | 1.5 | 15.9 | 435 | 259 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10+1×6 | 0.7 | 1.5 | 18.9 | 649 | 359 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Five Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
In the air | Buried in soil | |||||||||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
5×4 | 0.7 | 1.5 | 14.5 | 349 | 223 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
5×6 | 0.7 | 1.5 | 15.8 | 460 | 271 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
5×10 | 0.7 | 1.5 | 19.3 | 699 | 384 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Products Show
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client’s information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client’s requirement.
Shipping Terms |
DHL, UPS,FEDEX, TNT, or designated forwarder. |
Payment Terms |
T/T, Western Union, or PayPal |
Freight cost |
Prepay with goods payment or pay by collected. |
Packaging |
Packed in bulk or as request |
Carton Measure |
49*33*23.5cm, 33*30*15cm, 30*30*18cm |
medium and low voltage electric wire cable Single core copper conductor aluminum 3 core PVC insulated power cable 0.6/1 – 11kV
Contact Us By Follow Information
Sales Manager: Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No./whatsapp/wechhat:+86 15053169342
Tel:+86-531-88698938 Fax:+86-531-88662923
Web:luxingcable.en. / luxingcable.en.
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,China
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,China
Sales Manager: Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No./whatsapp/wechhat:+86 15053169342
Tel:+86-531-88698938 Fax:+86-531-88662923
Web:luxingcable.en. / luxingcable.en.
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,China
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,China
We are China 300 mm2 XLPE Low Voltage Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 300 mm2 Cable Products
Popular 300 mm2 Power Cable Products
Popular 300 mm2 XLPE Low Voltage Power Cable Products
Popular luxingcable Products
Copper Conductor PVC Insulted Fine Steel Wire Armoured PVC Sheathed Electrical Cable VV32
XLPE Copper Insulated Power Overhead Electrical/Electric Wire Cable
Best Quality Electrical Cable Wire 3mm with Low Price
Building Used Copper 10mm Electrical Cable Wire Manufacturer Wire
High Quality 2 Cores / 3 Corepvc Insulated and Sheathed 600/1000V
Low Voltage 220-660V Fs Swa Flat Rubber Cable
Tags: 300 mm2 Cable, 300 mm2 Power Cable, 300 mm2 XLPE Low Voltage Power Cable, luxingcable