30kv Metal Oxide Lightning Protector Arrester for Outdoor
30kv Metal Oxide Lightning Protector Arrester for Outdoor image
Get Latest Price Request a quote
Basic Info.
Product Description
Surge Arrester Series
General
1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite)
2. Application:for protection of power transmission & distribution system from over-voltage.
3. Features:
1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.
2)Easy installation and maintenance.
3)Good sealing capability to ensure reliable operation.
4)Protection and reliability of the surge arrester have been greatly enhanced.
Working Condition
1. Ambient air temperature:-40ºC ~+40ºC ;
2. Altitude:<=2000m;
3. Frequency: 48Hz~62Hz;
4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter;
5. Earthquake intensity is less than 8 degree;
6. Max. Wind speed is 35m/s.
Main Techical Parameter
1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-5W-6 | 6 | 5.1 | 18 | 320 | 150 | 65 | |
| YH-5W-9 | 9 | 7.65 | 27 | 430 | 150 | 65 | |
| YH-5W-12 | 12 | 10.2 | 36 | 430 | 150 | 65 | |
| YH-5W-15 | 15 | 12.75 | 45 | 530 | 150 | 65 | |
| YH-5W-18 | 18 |
15.3 |
54 | 530 | 150 | 65 | |
| YH-5W-21 | 21 | 16.8 | 63 | 640 | 150 | 65 | |
| YH-5W-24 | 24 | 19.2 | 72 | 640 | 150 | 65 | |
| YH-5W-27 | 27 | 21.6 | 81 | 740 | 150 | 65 | |
| YH-5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| YH-5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| YH-5W-36 | 36 | 28.8 | 108 | 1115 | 150 | 65 |
2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-10W-6 | 6 | 5.1 | 18 | 1 | 320 | 250 | 100 |
| YH-10W-9 | 9 | 7.65 | 27 | 1 | 430 | 250 | 100 |
| YH-10W-12 | 12 | 10.2 | 36 | 1 | 430 | 250 | 100 |
| YH-10W-15 | 15 | 12.75 | 45 | 1 | 530 | 250 | 100 |
| YH-10W-18 | 18 | 15.3 | 54 | 1 | 530 | 250 | 100 |
| YH-10W-21 | 21 | 16.8 | 63 | 1 | 640 | 250 | 100 |
| YH-10W-24 | 24 | 19.2 | 72 | 1 | 740 | 250 | 100 |
| YH-10W-27 | 27 | 21.6 | 81 | 1 | 740 | 250 | 100 |
| YH-10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| YH-10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| YH-10W-36 | 36 | 28.8 | 108 | 1 | 1115 | 250 | 100 |
| YH-10W-42 | 42 | 33.6 | 126 | 2 | 1260 | 400 | 100 |
| YH-10W-48 | 48 | 39 | 139 | 2 | 1260 | 400 | 100 |
| YH-10W-54 | 54 | 42 | 160 | 2 | 1260 | 400 | 100 |
| YH-10W-60 | 60 | 48 | 178 | 2 | 1465 | 400 | 100 |
| YH-10W-66 | 66 | 52.8 | 196 | 2 | 1465 | 400 | 100 |
| YH-10W-72 | 72 | 57 | 214 | 2 | 2255 | 400 | 100 |
| YH-10W-84 | 84 | 67.2 | 244 | 2 | 2255 | 400 | 100 |
| YH-10W-90 | 90 | 72.5 | 249 | 2 | 2255 | 400 | 100 |
| YH-10W-96 | 96 | 75 | 265 | 3 | 3555 | 800 | 100 |
| YH-10W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-10W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-10W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-10W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-20W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-20W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-20W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y5W-6 | 6 | 5.1 | 18 | 280 | 150 | 65 | |
| Y5W-9 | 9 | 7.65 | 27 | 320 | 150 | 65 | |
| Y5W-12 | 12 | 10.2 | 36 | 320 | 150 | 65 | |
| Y5W-15 | 15 | 12.75 | 45 | 450 | 150 | 65 | |
| Y5W-18 | 18 |
15.3 |
54 | 450 | 150 | 65 | |
| Y5W-21 | 21 | 16.8 | 63 | 450 | 150 | 65 | |
| Y5W-24 | 24 | 19.2 | 72 | 510 | 150 | 65 | |
| Y5W-27 | 27 | 21.6 | 81 | 510 | 150 | 65 | |
| Y5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| Y5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| Y5W-36 | 36 | 28.8 | 108 | 890 | 150 | 65 |
5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y10W-6 | 6 | 5.1 | 18 | 1 | 280 | 250 | 100 |
| Y10W-9 | 9 | 7.65 | 27 | 1 | 320 | 250 | 100 |
| Y10W-12 | 12 | 10.2 | 36 | 1 | 320 | 250 | 100 |
| Y10W-15 | 15 | 12.75 | 45 | 1 | 450 | 250 | 100 |
| Y10W-18 | 18 | 15.3 | 54 | 1 | 450 | 250 | 100 |
| Y10W-21 | 21 | 16.8 | 63 | 1 | 450 | 250 | 100 |
| Y10W-24 | 24 | 19.2 | 72 | 1 | 510 | 250 | 100 |
| Y10W-27 | 27 | 21.6 | 81 | 1 | 510 | 250 | 100 |
| Y10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| Y10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| Y10W-36 | 36 | 28.8 | 108 | 1 | 890 | 250 | 100 |
| Y10W-42 | 42 | 33.6 | 126 | 2 | 1256 | 400 | 100 |
| Y10W-48 | 48 | 39 | 139 | 2 | 1256 | 400 | 100 |
| Y10W-54 | 54 | 42 | 160 | 2 | 1256 | 400 | 100 |
| Y10W-60 | 60 | 48 | 178 | 2 | 1440 | 400 | 100 |
| Y10W-66 | 66 | 52.8 | 196 | 2 | 1440 | 400 | 100 |
| Y10W-72 | 72 | 57 | 214 | 2 | 1440 | 400 | 100 |
| Y10W-84 | 84 | 67.2 | 244 | 2 | 2200 | 400 | 100 |
| Y10W-90 | 90 | 72.5 | 249 | 2 | 2200 | 400 | 100 |
| Y10W-96 | 96 | 75 | 265 | 3 | 3350 | 800 | 100 |
| Y10W-108 | 108 | 84 | 281 | 3 | 3350 | 800 | 100 |
| Y10W-120 | 120 | 96 | 300 | 3 | 3948 | 800 | 100 |
| Y10W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y10W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| Y20W-120 | 120 | 96 | 300 | 3 | 4106 | 800 | 100 |
| Y20W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y20W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
| Y20W-444 | 444 | 324 | 1106 | 4 | 17052 | 2000 | 100 |
Note: For details, please refer to the catalogue.
Participate in the exhibition pictures
testing report
We are China 30kv Metal Oxide Lightning Protector Arrester for Outdoor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 30kv Lightning Protector Products
Popular Lightning Protector Products
High Quality Surge Protection Lightning Arrestor
110kv Metal Oxide Lightning Arrester
Rated Voltage 27kv Lightening Arrester/Hangzhou Professional Manufactory
Station Class 30kv 33kv Polymer Polymeric Metal Oxide Lightning Arrester
Substation 500kv/50ka Advanced Lightning Arrestor Porcelain Surge Arrester
Polymer Housed Transformer Protector Arrestor Lightning
Popular Metal Oxide Lightning Protector Products
18kv Metal Oxide Lightning Protector Arrester for Outdoor
36kv Metal Oxide Lightning Protector Arrester for Outdoor
24kv Metal Oxide Lightning Protector Arrester for Outdoor
27kv Metal Oxide Lightning Protector Arrester for Outdoor
9kv Metal Oxide Lightning Protector Arrester for Outdoor
12kv Metal Oxide Lightning Protector Arrester for Outdoor
Popular people Products
Pin Composite Insulator for High Voltage Overhead Transmission Line
Polymer Housed Metal Oxide Surge Arrester Without Gaps
24kv 160kn Silicone Rubber Composite Insulator for Support Cable
Suspension Type Composite Insulator for High Voltage Overhead Transmission Line
Hardware Fitting Ball Eyes Accessorie
24kv Pin Silicone Rubber Polymer Insulator for Support Wire
Tags: 30kv Lightning Protector, Lightning Protector, Metal Oxide Lightning Protector, people