31.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer

China 
                31.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer
              manufacture and supplier

31.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer image

Get Latest Price Request a quote

Basic Info.

Model NO.
SFS10-31500/110

Cooling Method
Oil-immersed Type Transformer

Winding Type
Two-winding Transformer

Certification
ISO9001-2000, ISO9001, CCC

Usage
Combined Transformer, Power Transformer, Three Phase

Frequency Characteristics
High Frequency

Shape of Core
Ring

Brand
Ville

Test Certification
CQC Transformer Test

Voltage Range Hv
110/115/121/+-2X2.5%

LV
6.3/6.6/10.5/11/

Rated Power Definitionwer
31500kVA

Tap Changer
Mr or Hm China

Vector Group
Yn, D11

Transport Package
Wooden Cases and Main Body Nude Packing

Specification
IEC Standard

Trademark
vilLE

Origin
China

HS Code
8504231200

Production Capacity
1set/6monthes

Packaging & Delivery

Package Size
6060.00cm * 4930.00cm * 5010.00cm

Package Gross Weight
50000.000kg

Product Description

31500kVA 110KV S10 Dual-winding Power Transformer with on load tap changer

Technical parameters:
Voltage combination and tapping range HV:110kv 115kv 121kv+-2×2.5%
                                                               LV: 6.3 6.6 10.5 11
Connection group:yn,d11
Winding combination:H-L
No-load current(%):0.64
No-load loss(kW):31.5
On-load loss(kW ):143
Lmpedance(%):10.5
Weight of active part(kg) Around:50ton
Transport weight(kg):Around 57ton(filling with nitrogen)
Transport dimension (L W H mm):6060x4930x5010
Capacity:31500kva

Structure characteristic:
1,Iron core
1. 1The iron core adopts cold-rolled crystal-oriented silicon steel plate 30Z140 with high quality, low-loss, and no
time effect, sheared by Geroge line and with no burr. 1.2 Iron core adopts pulling board structure, the upper
and down yoke is clamped by board, to form the frame structure. The iron core adopts advanced lamination
process, which effectively controls the no-load loss and electro-magnetic noise.

2 Winding
2.1 Winding adopts mature structure, which ensure the reliability of transformer operation.
2.2 The insulation power field intensity between turns shall be controlled no greater than 1.6kV/mm.

3,Body
3.1 Body adopts mature insulation structure, and strictly guarantee the main axial insulation margin.
3.2 Body mostly adopt multi-coil whole assembly, processed in constant voltage and evaporation, which made
coil shrink evenly and with less rebounce, and enhance the electric strength and mechanical strength.

3.3 Adopt laminating wood board or thermal shaped insulation cardboard. Pressed tightly with pin, which ensure
the winding is constantly pressed tightly. 

4,leading wire
4.1 The layout of all leading wire is reasonable, which guarantees the enough electric distance and mechanical
strenth. 

4.2 All leading wire is cirlulized ,which guarantee the reliable wild or prize connection. 

5,Oil tank
5.1 Oil tank adopts structure of flat top, bell jar type, which add the mechanical strength of oil tank and also
make the appearance beautiful and graceful, site installation tend to be more convenient.

5.2 Pipeline with gas relay such as the oil tube and bushing hoist support on top of oil tank is with hoist
gradient, to facilitate the gas in transformer flow to gas relay.

5.3 Vacuum oiling is adopted, there is no leakage and permanent distortion in the following test. vacuum-
pumping :759mmHg load voltage test: bear 2 times the oil pressure of oil conservator oil surface for 24 hours.

5.4 The structure of transformer is convenient for disassembly and change of bushing and porcelain element.
5.5 The oil drip valve is set on the bottom of oil tank, sampling valve is set in the middle.
5.6 collective gas connecting tube is fixed on the bushing hoist support.
5.7 Transformer is of full-sealed structure, the upper and down oil tanks are required to welded fully. 

6,Oil conservation tank 
6.1 Adopt capsule type, finger type oil level indicator oil conservation tank. 
6.2 The structure is convenient for internal cleaning, the capacity can ensure no oil overflow in 40 ambient
temperature with full load, and oil shall be seen from oil level indicator before put into operation in -25.

6.3 Oil conservation tank is equipped with oil-sealed moisture absorber. 

7,Safety protection device:
7.1 Gas relay is fixed in transformer, the standard complies with ZBK41004-89Gas relay.
7.2 There is enough and reliable pressure release device, and matched with oil spray pipe, the direction of oil
spraying is downward. 

8,Oil temperature measuring device:
8.1 There is pipe support of mercury thermometer, which is  set on the top of oil tank.
8.2 There is temperature controller,  the accuracy of thermometer complies with the related standard. Quantity
and technical requirement shall as per tender document. 

9,Each component  of transformer shall be prefabricated once in manufacture factory, marked, to ensure the
smooth procedure of site assembly. Before Ex-factory, inner core shall be check, and clean the fifth in
transformer.

Structure:

Packing and Shipping



 

Packaging Details: The accessories packed in plywood cases,the main body in nude.

Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE  knows the value of your time.

Our Best Service For You

1. Pre sale service
A. Make technical solution
B. Send quotation, technical data sheet and drawing
C. Prepare power transmission plan, testing plan,and shipment plan
2. In sale service
A. Supervise the manufacturing schedule totally in accordance with the plan
B. Send photos to customer during every manufacturing process(hold point)
C. Inform the customer one week before testinng.
3. After sale service
A. Installation and commissioning, training the workers
B. Quick response within 12 hours any time
C. Provide 12 months gurantee period normally.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China 31.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 31.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer Products

  • No related articles
  • Popular cnville Products

    Bk-5000V Single-Phase Isolation Transformer 380V220V to 380V220V200V110V36V24V2000V2K5000V5K

    Electrical off-Circuit Tap Changer Transformer Tap Changer Transformer Breaker Switch

    Hxgn1-12 Cubicle Fixed Indoor AC Metal-Clad Ring Main Unit Switchgear

    Mining Movable Dry Transformer Substation Mining Explosion-Proof Dry Type Transformer

    80kVA 10kv Wond Core Type Hermetically Sealed Oil Immersed Transformer/Distribution Transformers

    Zw39-40.5 High Voltage Vacuum Circuit Breaker

    Popular Powertransformer High Quality Products

    Sfz10-6300/110 6.3mva 110kv Dual-Winding Load Tapping Power Transformer

    Sfsz10-8000/110 8mva 110kv Three-Winding Load Tapping Power Transformer

    Sfsz10-50000/110 50mva 110kv Three-Winding Load Tapping Power Transformer

    S10-360000/220kv 360mva S10 Series 220kv Double-Winding off-Circuit-Tap-Changer Power Transformer

    Sfs10-25000/110 25mva 110kv Three-Winding No-Excitation Tapping Power Transformer

    Sfs10-50000/110 50mva 110kv Three-Winding No-Excitation Tapping Power Transformer

    Popular Transformer on Sales Products

    Sfs10-12500/110 12.5mva 110kv Three-Winding No-Excitation Tapping Power Transformer

    Sfz10-16000/110 16mva 110kv Dual-Winding Load Tapping Power Transformer

    S10 31500/220kv 31.5mva S10 Series 220kv Three-Winding off-Circuit-Tap-Changer Power Transformer

    16mva 110kv Dual-Winding No-Load Tapping Power Transformer

    Sfz10-20000/110 20mva 110kv Dual-Winding Load Tapping Power Transformer

    S10-360000/220kv 360mva S10 Series 220kv Double-Winding off-Circuit-Tap-Changer Power Transformer

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION