33kv Aluminium Conductor Urd Cable Electrical Cable
33kv Aluminium Conductor Urd Cable Electrical Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
We are China 33kv Aluminium Conductor Urd Cable Electrical Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 33kv Aluminium Conductor Products
Popular Electrical Cable Products
Great Price Professional 240mm Power Electrical Cable
Electric Wire XLPE Insulated Copper Power Cable
Electrical XLPE Insulated Sheathed Steel Tape Power Cable
6.6kV XLPE Insulated AL Aluminum Conductor Short Circuit Screen Underground Cable
Low Voltage XLPE Insulated PVC Sheathed Steel Wire Armored Copper Electrical Wire
Popular huatongcable Products
Overhead Triplex Service Drop Cherrystone Aerial Bundled Cable for Transmission Line
ASTM Standard Stay Wire, Guy Wire Stranded Galvanized Steel Wire 3/8
Bare Overhead Conductor AAAC 50mm2 with DIN 48201 Standard
ASTM B475 Utility, Common, High Tensile, Extra Tensile, Galvanized Stranded Steel Wire
35kv Copper Conductor 120mm2 Armored XLPE Power Cable
Popular Urd Cable Products
ASTM Standard 600V XLPE Insulated Urd Cable
Duplex Conductor 600V Secondary Type Urd Cable - Aluminum Conductor
500MCM Aluminum URD Cable 100% TRXLPE Insulated MV-90 35kV 1/3 Neutral
8AWG-1000 Kcmil Underground Distribution Cws Shield 25kv Aluminum 35kv Urd Cable
XLPE or Epr PVC PE Standard Export Drum 15 Kv Urd Cable
Tags: 33kv Aluminium Conductor, Electrical Cable, huatongcable, Urd Cable