3*95 mm2 Overhead Conductor Cable ABC Aluminum Stranded Wire

China 
                        3*95 mm2 Overhead Conductor Cable ABC Aluminum Stranded Wire
                      manufacture and supplier

3*95 mm2 Overhead Conductor Cable ABC Aluminum Stranded Wire image

Get Latest Price Request a quote

Quick Details

3*95 mm2 Overhead Conductor Cable ABC Aluminum Stranded Wire

low voltage

Hnbf Cable

ISO9001, CE, CCC, RoHS

Overhead

Round Wire

PE/XLPE

None

Aluminum

Overhead

Stranded

Insulated

ASTM, BS, IEC, NFC, DIN, GB

Customized

Fob, CIF, CFR…

Provided

HNBF Cable

Wooden Drum. Iron-Wooden Drum

0.75(sqmm),1.0,1.5,2.5,4,6,10,16,25,35,50,70.

Zhengzhou China

8544492100

Product Details

Product Description

Specifications and Standards: 

Copper core/Aluminium core/Aluminium alloy core PE/XLPE insulated ABC Cable

IEC,NFC,ASTM,BS,DIN…

1.Product Description

ABC Cable(Aerial Bundled Cables or Aerial Bundled Conductors) are several phase conductors insulated and

tightly bundled together with bare/insulatd neutral conductor for use in overhead power lines.

       2 cores                                         3 cores                      4 cores                            5 cores

                                                         structure chart

2.Standard

ASTM Standard Service Drop Cable (Duplex)

                          Phase Conductor                                        Bare Neutral                 Nominal Weight(kg/km)

Code Word Size&Number of Wires Insulation Thickness (mm) Nominial Diameter
Bare(mm)
Nominial Diameter
O.D.(mm)
Size&Number of Wires Rated Strength (kg) XLPE AL or Alloy Total Ampacity(A) Coils(m) Reels(m)
AAC                        
Doberman 2-7 1.14 7.4 9.7 2-7 612 38.7 184.5 223 136 152 500
Airedale 1-19 1.52 8.4 11.5 1-7 56.5 233.6 290 158 152 500
AAAC                        
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2023 64.0 296.1 360 182 152 457
Heeler 1-19 1.52 9.4 12.5 1/0-7 2023 64.0 296.1 360 182 152 457
ACSR                        
Shepherd 6-7 1.14 4.6 6.9 6-6/1 540 23.8 72.9 97 78 305 1000
Terrier 4-7 1.14 5.9 8.2 4-6/1 844 29.8 116.1 146 103 305 500

ASTM Standard Service Drop Cable (Triplex)

                 Phase Conductor                                           Bare Neutral                 Nominal Weight(kg/km)

Code Word Size&Number of Wires Insulation Thickness (mm) Nominial Diameter
Bare(mm)
Nominial Diameter
O.D.(mm)
Size&Number of Wires Rated Strength (kg) XLPE AL or Alloy Total Ampacity(A) Coils(m) Reels(m)
AAC                        
Tusk 4/0-7 2.03 13.26 17.3 4/0-7 1737 243 899 1141 279 305
Chiton 266.8-19 2.03 14.88 18.9 266.8-19 2254 277 1133 1409 310 305
AAAC                        
Hippa 6-7 1.14 4.65 6.9 6-7 499 48 118 165 78 305 671
Cabera 6-7 1.14 4.65 6.9 6-7 499 48 118 165 78 305 671
ACSR                        
Paludina 6-1 1.14 4.115 6.401 6-6/1 540 42 112 170 79 305 762
Voluta 6-7 1.14 4.67 6.960 6-6/1 540 48 112 176 79 305 671

ASTM Standard Service Drop Cable (Quadruplex)

                            Phase Conductor                                  Bare Neutral                     Nominal Weight(kg/km)

Code Word Size&Number of Wires Insulation Thickness (mm) Nominial Diameter
Bare(mm)
Nominial Diameter
O.D.(mm)
Size&Number of Wires Rated Strength (kg) XLPE AL or Alloy Total Ampacity(A) Coils(m) Reels(m)
AAC                        
Mustang 2-7 1.143 7.417 9.703 2-7 612.347 115 377 491 158 548.6
Shire 1-19 1.524 8.433 11.481 1-19 743.886 171 475 646 158 548.6
AAAC                        
Belgian 2-7 1.143 7.417 9.703 2-7 1270.052 115 391 506 136 548.6
Sherland 1/0-19 1.524 9.474 12.522 1/0-7 2023.011 193 624 817 182 365.8
ACSR                        
Morgan 4-1 1.143 5.182 7.468 4-6/1 843.677 79 238 344 103 152.4 518.2
Palomino 2-7 1.143 7.417 9.703 2-6/1 1292.732 115 377 557 136 548.6

3.Characteristics

Rated voltage Uo/U is 0.6/1kv.

Max.Continuouspermissive working temperature of conductor:PVC insulation should be not more than 70ºC,and XLPE insulation should be not more than 90ºC.

* The installation temperature of cable  should be not less than -20ºC.

* When overall diameter of cable (D) is less than 25mm, permissive bending radius of cable should be not less than 4D.When overall diameter(D) of cable is equal to and

above 25mm, permissigve bending radius of cable should be not less than 6D.

 
 PACKAGINGandSHIPPING

For the ABC cable ,we usually use the standard wooden drum to package as the belowing picture.We can design the different package types according to the customer’s requirements.

 

BEST SERVICES!
 

1.Custom Merchandise: we can make cable as your need include the color ,size and so on.we also offer OEM /ODM.

2.Own Factory:  Reliable source of raw materials,we can offer you the factory price.

3.Free sample:  Free Sample to provide ,but the sample freight must be paied by customers;

4.Speed Delivery: 15-30 days,Professional transport team.

5.All type test:  Professional technical equipment ensure the high quality.

ABC Cable 

We have the complete and systemly production process in each aspects:

1).Aluminum rod drawing at first step and then stranding,extruding insulation, cabling,packing and inspect in the end;

2).100% Product inspect from raw material to the finished products;

3).All the products have the test report;

Certifications

1.ISO9001

2.CCC

3.CE

4.RoHS

 

 COMPANY INFORMATION
 

Henan Baofeng  Cable Co.Ltd. is founded by one of the most professional manufacturers.We specialize in producing and exporting all kinds of wires

and cables.We

have advanced tech-staff, advanced equipment and  25 year’s experience engineer.Welcome to visit  at any time.Since we were founded, we have

been built favorable

business relationship with many customers from all over the world.

Contact Us

Name:Elaine

Phone:+8615036788244

 
 
 

 

We are China 3*95 mm2 Overhead Conductor Cable ABC Aluminum Stranded Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 0.6/1kv Electrical Wire Cable Products

4 Cores 50mm2 Overhead ABC Aerial Bundled Electrical Wire Cable

Quadruplex PE/XLPE Secondary Ud Cable ABC Cable Wire

Duplex/Triplex/Quadruplex Cable Wire ABC Cable (Aerial Bundled Cable)

Covered Wire ASTM Standard Overhead Conductor PE/XLPE Insulated ABC Cable Wire

Aluminium Stranded Conductor Wire ABC Cable ASTM Standard

Popular 3*95 mm2 ABC Cable Wire Products

Aluminium Stranded Conductor Wire ABC Cable ASTM Standard

Covered Wire ASTM Standard Overhead Conductor PE/XLPE Insulated ABC Cable Wire

Popular hnbfcable Products

IEC Standard Hard Drawn 16 25 35 Sqmm Bare Copper Stranded Conductor

Galvanized Steel Stay Wire Zinc Coated Earth Wire

Electric Aluminium Alloy Wire Bare AAC Conductor

DIN Standard AAAC Bare Aluminum Alloy Conductor

0.6/1kv Aluminium Conductor XLPE Insulated Electrical ABC Cable

BS Standard Oak 100mm2 AAAC All Aluminum Alloy Conductor

Popular Quadruplex ABC Cable Products

Multi-Size 11kv ABC Cable Current Carrying Capacity Suppliers

0.6/1 Kv 6.35/11kv 12.7/22kv Triplex Quadruplex ABC Cable

1kv XLPE Aluminum Power Line Service Drop Wire Overhead Aerial Bundle Conductor ABC Cable Manufacturer

150mm 3c Quadruplex Aerial Triplex ABC Drop Cable

Overhead XLPE Insulated Quadruplex Service Drop ABC Cable

Low Voltage 4X35mm2 Aluminium Overhead ABC Aerial Bundled Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION