3X240mm2 XLPE Cable
3X240mm2 XLPE Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Workshop
Shipment
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Specification:
| 7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 3.4 | 0.1 | 2.1 | 38.7 | 1.3 | 1.75 | 1.2 | 0.727 |
| 35 | 6.9 | 3.4 | 0.1 | 2.2 | 40.9 | 1.47 | 2.22 | 0.868 | 0.524 |
| 50 | 8.2 | 3.4 | 0.1 | 2.3 | 43.9 | 1.7 | 2.5 | 0.641 | 0.387 |
| 70 | 9.7 | 3.4 | 0.1 | 2.4 | 47.3 | 2.02 | 3.25 | 0.443 | 0.268 |
| 95 | 11.3 | 3.4 | 0.1 | 2.5 | 51 | 2.42 | 4.12 | 0.32 | 0.193 |
| 120 | 12.8 | 3.4 | 0.1 | 2.6 | 54.4 | 2.79 | 4.95 | 0.253 | 0.153 |
| 150 | 14.2 | 3.4 | 0.1 | 2.7 | 57.6 | 3.17 | 5.87 | 0.206 | 0.124 |
| 185 | 15.9 | 3.4 | 0.1 | 2.8 | 61.5 | 3.69 | 7.06 | 0.164 | 0.0991 |
| 240 | 18.3 | 3.4 | 0.1 | 2.9 | 66.9 | 4.38 | 8.82 | 0.125 | 0.0754 |
| 300 | 20.4 | 3.4 | 0.1 | 3.1 | 71.8 | 5.11 | 10.68 | 0.1 | 0.0601 |
| 400 | 23.2 | 3.4 | 0.1 | 3.3 | 78.3 | 6.24 | 13.32 | 0.0778 | 0.047 |
| 500 | 26.4 | 3.4 | 0.1 | 3.5 | 86.4 | 7.63 | 16.5 | 0.0605 | 0.0366 |
| 8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | Ω/km | Ω/km | |
| 25 | 6 | 4.5 | 0.1 | 2.3 | 43.9 | 1.57 | 2.02 | 0.927 | 0.727 |
| 35 | 6.9 | 4.5 | 0.1 | 2.4 | 46 | 1.75 | 2.38 | 0.668 | 0.524 |
| 50 | 8.2 | 4.5 | 0.1 | 2.4 | 48.8 | 2 | 2.85 | 0.4936 | 0.387 |
| 70 | 9.7 | 4.5 | 0.1 | 2.5 | 52.3 | 2.34 | 3.57 | 0.342 | 0.268 |
| 95 | 11.3 | 4.5 | 0.1 | 2.6 | 55.9 | 2.75 | 4.45 | 0.2464 | 0.193 |
| 120 | 12.8 | 4.5 | 0.1 | 2.7 | 59.4 | 3.16 | 5.32 | 0.1955 | 0.153 |
| 150 | 14.2 | 4.5 | 0.1 | 2.8 | 62.6 | 3.57 | 6.27 | 0.1587 | 0.124 |
| 185 | 15.9 | 4.5 | 0.1 | 2.9 | 66.4 | 4.07 | 7.45 | 0.1271 | 0.0991 |
| 240 | 18.3 | 4.5 | 0.1 | 3.1 | 72 | 4.82 | 9.25 | 0.0976 | 0.0754 |
| 300 | 20.4 | 4.5 | 0.1 | 3.3 | 77 | 5.71 | 11.28 | 0.0778 | 0.0601 |
| 400 | 23.2 | 4.5 | 0.1 | 3.4 | 83.2 | 6.78 | 13.86 | 0.0615 | 0.047 |
| 500 | 26.4 | 4.5 | 0.1 | 3.5 | 91.1 | 8.2 | 17.32 | 0.0487 | 0.0366 |
| 9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm 2 | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | – | ||||||||
| 35 | 6.9 | 5.5 | 0.1 | 2.4 | 50.3 | 2 | 2.63 | 0.868 | 0.668 |
| 50 | 8.2 | 5.5 | 0.1 | 2.5 | 53.3 | 2.26 | 3.11 | 0.641 | 0.4936 |
| 70 | 9.7 | 5.5 | 0.1 | 2.6 | 56.8 | 2.62 | 3.85 | 0.443 | 0.342 |
| 95 | 11.3 | 5.5 | 0.1 | 2.8 | 60.6 | 3.07 | 4.77 | 0.32 | 0.2464 |
| 120 | 12.8 | 5.5 | 0.1 | 2.9 | 64.1 | 3.49 | 5.65 | 0.253 | 0.1955 |
| 150 | 14.2 | 5.5 | 0.1 | 3 | 67.3 | 3.91 | 6.61 | 0.206 | 0.1587 |
| 185 | 15.9 | 5.5 | 0.1 | 3.1 | 71.2 | 4.44 | 7.81 | 0.164 | 0.1271 |
| 240 | 18.3 | 5.5 | 0.1 | 3.3 | 76.8 | 5.21 | 9.64 | 0.125 | 0.0976 |
| 300 | 20.4 | 5.5 | 0.1 | 3.3 | 81.3 | 6.1 | 11.66 | 0.1 | 0.0778 |
| 400 | 23.2 | 5.5 | 0.1 | 3.5 | 87.7 | 7.2 | 14.28 | 0.0778 | 0.0615 |
| 500 | 26.4 | 5.5 | 0.1 | 3.8 | 96 | 9.15 | 17.8 | 0.0605 | 0.0487 |
| 10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | |||||||||
| 50 | 8.2 | 8 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.641 | 0.4936 |
| 70 | 9.7 | 8 | 0.1 | 3 | 68.4 | 3.42 | 4.65 | 0.443 | 0.342 |
| 95 | 11.3 | 8 | 0.1 | 3.1 | 72 | 3.89 | 5.59 | 0.32 | 0.2464 |
| 120 | 12.8 | 8 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.253 | 0.1955 |
| 150 | 14.2 | 8 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.206 | 0.1587 |
| 185 | 15.9 | 8 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.164 | 0.1271 |
| 240 | 18.3 | 8 | 0.1 | 3.5 | 88 | 6.22 | 10.66 | 0.125 | 0.0976 |
| 300 | 20.4 | 8 | 0.1 | 3.7 | 92.9 | 7.2 | 12.77 | 0.1 | 0.0778 |
| 400 | 23.2 | 8 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
| 500 | 26.4 | 8 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |
We are China 3X240mm2 XLPE Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jpcable99 Products
Stranded Acs Wire, Aluminium Clad Steel Wire
High Quality 1/11kv XLPE Insulated Steel Wire Armoured Cable
High Quality PVC Insulated Unarmored Underground Power Cable
European Standard XLPE Insulated Underwater Electric Cable (YJV/YJV22/YJV32)
Copper Core Steel Wire Armoured Electric Cable, Power Cable
High Quality ABC Aerial Bundled Cable with IEC60502 Standard
Popular Unarmoured Cable Products
3 Core Aluminum XLPE /PVC Insulated Unarmoured Power Cable
35 Kv Power Cable 1X500mm2 Cu/XLPE/PVC Unarmoured
IEC 60502-2 Kabel Xruhakxs 12/20kv Medium Voltage Unarmoured Cable
Medium Voltage XLPE Insulated Unarmoured Power Cable
Low Voltage Multicore XLPE Insualted Unarmoured Power Cable with Ce Certificate
Medium Voltage XLPE Insulated Unarmoured Power Cable
Popular XLPE Cable Products
High Voltage Single Core Under Armour Power Cable
Power Cable 0.6/1kv Copper Conductor XLPE Insulation PVC Sheath for Underground
10kv Copper Core XLPE Insulated Cable
Five Cores Aluminum Conductor XLPE Cable 300mm
Copper Conductor XLPE Insulated 0.4kV Power Cable 2X6mm2
Popular XLPE Insulated Cable Products
3*6 AWG UL854 Concentric Cable
25kv 185mm2 Sac Spaced Aerial Cable
Hot Seller Medium Voltage XLPE Insulated Unarmoured Power Cable
0.6/1kv Duplex/Triplex/Quadruplex ABC Aerial Bundle Cable Cable
Overhead Aluminum Core PVC PE XLPE Insulated ABC Cable
0.6/1kv NFC/ASTM/BS/IEC Standard Electric Cable ABC Cable
Tags: jpcable99, Unarmoured Cable, XLPE Cable, XLPE Insulated Cable