50mm PVC Insulated and Sheathed Power Cable
50mm PVC Insulated and Sheathed Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Appplication:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
Voltage: 0.6/1KV, 6/35KV
Number Of core: 1 core, 2 core, 3 core, 4 core, 5 core
3+1 cores, 3+2 cores, 4+1 cores
1) Copper (aluminium) cores / XLPE insulated / PVC(PE) sheathed power cable
2) Copper (aluminium) cores /XLPE insulated /steel tape armored/ PVC ( PE) sheathed power cable
3) Copper (aluminium) cores /XLPE insulated / thin steel wire armored/ PVC ( PE) sheathed power cable
4) Copper (aluminium) cores /XLPE insulated / thick steel wire armored/ PVC ( PE) sheathed power cable
The products can be produced according to our factory specification which is equivalent to the standard IEC60502. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.
Remarks: Including products for flame retardant, fire resistant and termite-proof
Specification:
| 1)3.6/6(7.2)kV, 3.6/6.6(7.2)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
| No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
| Al Conductor | Cu Conductor | ||||||||
| No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
| 3 X 25 | 6 | 2.5 | 0.1 | 1.2 | 0.2 | 1.9 | 37.9 | 1.87 | 2.32 |
| 3 X 35 | 6.9 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 41.5 | 2.1 | 2.73 |
| 3 X50 | 8.2 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 44.3 | 2.37 | 3.22 |
| 3 X 70 | 9.7 | 2.5 | 0.1 | 1.4 | 0.5 | 2.1 | 47.9 | 2.77 | 4 |
| 3 X 95 | 11.3 | 2.5 | 0.1 | 1.4 | 0.5 | 2.2 | 51.6 | 3.21 | 4.91 |
| 3 X 120 | 12.8 | 2.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.4 | 3.69 | 5.84 |
| 3 X 150 | 14.2 | 2.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 4.15 | 6.85 |
| 3 X 185 | 15.9 | 2.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.5 | 4.73 | 8.11 |
| 3 X 240 | 18.3 | 2.6 | 0.1 | 1.6 | 0.5 | 2.7 | 68.5 | 5.62 | 10.05 |
| 3 X 300 | 20.4 | 2.8 | 0.1 | 1.7 | 0.5 | 2.9 | 74.5 | 6.55 | 12.11 |
| 3 X 400 | 23.2 | 3 | 0.1 | 1.9 | 0.8 | 3.2 | 83.6 | 8.78 | 15.86 |
| 3 X 500 | 26.4 | 3.2 | 0.1 | 2.1 | 0.8 | 3.4 | 93 | 10.52 | 18.85 |
| 2)6/10(12)kV, 6.35/11(12)kV, , Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
| No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
| Al Conductor | Cu Conductor | ||||||||
| No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
| 3 X 25 | 6 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 43.4 | 2.16 | 2.61 |
| 3 X 35 | 6.9 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 45.4 | 2.36 | 2.99 |
| 3 X50 | 8.2 | 3.4 | 0.1 | 1.4 | 0.5 | 2.2 | 48.8 | 2.69 | 3.54 |
| 3 X 70 | 9.7 | 3.4 | 0.1 | 1.5 | 0.5 | 2.3 | 52.4 | 3.1 | 4.33 |
| 3 X 95 | 11.3 | 3.4 | 0.1 | 1.5 | 0.5 | 2.4 | 56.1 | 3.56 | 5.26 |
| 3 X 120 | 12.8 | 3.4 | 0.1 | 1.5 | 0.5 | 2.5 | 59.5 | 4.04 | 6.19 |
| 3 X 150 | 14.2 | 3.4 | 0.1 | 1.5 | 0.5 | 2.6 | 62.7 | 4.49 | 7.19 |
| 3 X 185 | 15.9 | 3.4 | 0.1 | 1.6 | 0.5 | 2.6 | 66.6 | 5.12 | 8.49 |
| 3 X 240 | 18.3 | 3.4 | 0.1 | 1.7 | 0.5 | 2.8 | 72.4 | 5.99 | 10.42 |
| 3 X 300 | 20.4 | 3.4 | 0.1 | 1.8 | 0.5 | 3 | 77.5 | 6.86 | 12.42 |
| 3 X 400 | 23.2 | 3.4 | 0.1 | 1.9 | 0.8 | 3.2 | 85.4 | 8.97 | 16.05 |
| 3 X 500 | 26.4 | 3.4 | 0.1 | 2 | 0.8 | 3.4 | 93.7 | 10.65 | 19.5 |
| 3)8.7/10(15)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
| No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
| Al Conductor | Cu Conductor | ||||||||
| No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
| 3 X 25 | 6 | 4.5 | 0.1 | 1.4 | 0.5 | 2.1 | 48.6 | 2.53 | 2.98 |
| 3 X 35 | 6.9 | 4.5 | 0.1 | 1.4 | 0.5 | 2.2 | 50.7 | 2.76 | 3.39 |
| 3 X50 | 8.2 | 4.5 | 0.1 | 1.5 | 0.5 | 2.3 | 53.9 | 3.1 | 3.95 |
| 3 X 70 | 9.7 | 4.5 | 0.1 | 1.5 | 0.5 | 2.4 | 57.4 | 3.51 | 4.74 |
| 3 X 95 | 11.3 | 4.5 | 0.1 | 1.5 | 0.5 | 2.6 | 61.2 | 4.05 | 5.75 |
| 3 X 120 | 12.8 | 4.5 | 0.1 | 1.6 | 0.5 | 2.6 | 64.7 | 4.56 | 6.72 |
| 3 X 150 | 14.2 | 4.5 | 0.1 | 1.6 | 0.5 | 2.7 | 67.9 | 5.04 | 7.74 |
| 3 X 185 | 15.9 | 4.5 | 0.1 | 1.7 | 0.5 | 2.8 | 71.9 | 5.66 | 9.04 |
| 3 X 240 | 18.3 | 4.5 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 6.56 | 11 |
| 3 X 300 | 20.4 | 4.5 | 0.1 | 1.9 | 0.8 | 3.2 | 84.1 | 8.39 | 13.96 |
| 3 X 400 | 23.2 | 4.5 | 0.1 | 2 | 0.8 | 3.3 | 90.5 | 9.71 | 16.79 |
| 3 X 500 | 26.4 | 4.5 | 0.1 | 2.1 | 0.8 | 3.5 | 98.8 | 11.45 | 20.57 |
| 4)12/20(24)kV, 12.7/22(24)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
| No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
| Al Conductor | Cu Conductor | ||||||||
| No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
| 3 X 25 | |||||||||
| 3 X 35 | 6.9 | 5.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.6 | 3.14 | 3.77 |
| 3 X50 | 8.2 | 5.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 3.49 | 4.34 |
| 3 X 70 | 9.7 | 5.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.1 | 3.93 | 5.16 |
| 3 X 95 | 11.3 | 5.5 | 0.1 | 1.6 | 0.5 | 2.6 | 65.7 | 4.46 | 6.16 |
| 3 X 120 | 12.8 | 5.5 | 0.1 | 1.7 | 0.5 | 2.7 | 69.4 | 5 | 7.15 |
| 3 X 150 | 14.2 | 5.5 | 0.1 | 1.7 | 0.5 | 2.8 | 72.6 | 5.49 | 8.19 |
| 3 X 185 | 15.9 | 5.5 | 0.1 | 1.8 | 0.5 | 3 | 76.9 | 6.16 | 9.53 |
| 3 X 240 | 18.3 | 5.5 | 0.1 | 1.9 | 0.8 | 3.2 | 83.9 | 7.87 | 12.31 |
| 3 X 300 | 20.4 | 5.5 | 0.1 | 2 | 0.8 | 3.2 | 88.6 | 8.96 | 14.52 |
| 3 X 400 | 23.2 | 5.5 | 0.1 | 2.1 | 0.8 | 3.5 | 95.4 | 10.35 | 17.43 |
| 3 X 500 | 26.4 | 5.5 | 0.1 | 2.2 | 0.8 | 3.7 | 103.7 | 12.45 | 20.23 |
| 5)18/30(36)kV, 19/33(36)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
| No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
| Al Conductor | Cu Conductor | ||||||||
| No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
| 3 X 25 | |||||||||
| 3 X 35 | |||||||||
| 3 X50 | 8.2 | 8 | 0.1 | 1.7 | 0.5 | 2.8 | 70.4 | 4.56 | 5.41 |
| 3 X 70 | 9.7 | 8 | 0.1 | 1.7 | 0.5 | 2.9 | 73.9 | 5.04 | 6.26 |
| 3 X 95 | 11.3 | 8 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 5.62 | 7.32 |
| 3 X 120 | 12.8 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 82.8 | 6.99 | 9.15 |
| 3 X 150 | 14.2 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 85.8 | 7.56 | 10.26 |
| 3 X 185 | 15.9 | 8 | 0.1 | 2 | 0.8 | 3.3 | 89.9 | 8.3 | 11.67 |
| 3 X 240 | 18.3 | 8 | 0.1 | 2.1 | 0.8 | 3.5 | 95.7 | 9.36 | 13.79 |
| 3 X 300 | 20.4 | 8 | 0.1 | 2.2 | 0.8 | 3.6 | 100.6 | 10.51 | 16.07 |
| 3 X 400 | 23.2 | 8 | 0.1 | 2.3 | 0.8 | 3.8 | 107.2 | 11.99 | 19.07 |
| 3 X 500 | 26.4 | 8 | 0.1 | 2.4 | 0.8 | 4 | 120.1 | 14.15 | 23.85 |
Workshop:
Shipment:
Certification:
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100, 000-sq. -FT. Building. In 2012, we operates in a new 666, 000 sq. Foot state-of-the-art facility in Xiaodian Industry Park., Xinxiang, Henan, China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor, such as AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ), such as Duplex, Triplex, Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4. Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America, Central America, North America, Europe, Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min. Order quantity?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted. But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow, we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3, 000, 000.00 for insulated aluminum cables and that is approx. USD8, 000, 000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country?
We don’t have professional installation teams in foreign country. But if that is necessary, we will recommend our partners to cooperate with you.
We are China 50mm PVC Insulated and Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
22kv Medium Voltage Underground XLPE Insulated Power Cable
ACSR Aluminum Stranded Conductor XLPE Insulated Aerial Bundled Cable
313mcm Locomotive Cable Dlo 2000V Cable
IEC Standard 25mm2 Rubber Insulated Welding Cable
4 Core Low Voltage Wire PVC Insulated and Sheathed Power Cable
Popular jpcable99 Products
AAAC Bare Conduct with Flint & Greely Standards Overhead Cable
0.6/1kv Aluminum Conductor XLPE Insulated ABC Cable
0.6/1kv Power Transmission Concentric Cable with ASTM Standard
Bare Overhead Aluminium Conductor Steel Reinforced ACSR Power Cable
ACSR Steel Core Wire as Per CSA C49 Standard
Popular Power Cable Products
4X35mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV Copper Core LV Power Cable
PVC Insulated 4 Core Cable Price
Low Voltage Copper Core /Aluminum Core XLPE Insulated Power Cable
Medium Voltage Copper Conductor Sta/Swa XLPE Insulated PVC Cable
Low Voltage PVC Insulated Power Cable
2.5mm/ 4mm/6mm/10mm AC/DC Copper Wire Solar Anti Ultraviolet Radiation PV Photovoltaic Cable
Popular PVC Insulated Cable Products
150mm2 Copper Conductor Cable PVC Insulated Cable
450/750V PVC Insulated Aluminum Cable
Rkub Soft Copper Underground Flexible Cable 120mm2 with PVC Insulated
Low Voltage 16mm 95mm Twisted Aluminum Aerial Bundled Cable
0.6/1kv Copper Conductor PVC Insulated Sta/Swa Armored Power Cable
35kv Copper or Aluminium 4 Core XLPE Insulated Power Cables
Tags: Cable, jpcable99, Power Cable, PVC Insulated Cable