600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG

China 
                        600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG
                      manufacture and supplier

600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG image

Get Latest Price Request a quote

Quick Details

600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG

THHN/THWN/TWN75/T90 8awg

Yifang

ISO9001, CE, UL, CCC

Building or Dwelling

Round Wire

PVC

Nylon

Copper

Building or Dwelling

Stranded

Insulated

6,8,10,12,14AWG

600V

Dry-Not Exceed 90 C

UL 83

Black, White, Red, Blue, Green, Yellow

yifang

Wooden Drum

ce ul

Zhengzhou, China

8544492100

Product Details

600v, building wire, THHN/THWN/TWN75/T90

Application

Type THHN or THWN-2* conductors are primarily used in conduit and cable
Trays for services, feeders and branch circuits in commercial or industrial applications as
Specified in the National Electrical Code® 2
? When used as Type THHN, conductor is suitable for use in dry locations at temperatures
Not to exceed 90° C
? When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at
Temperatures not to exceed 90° C or not to exceed 75° C when exposed to oil or coolant
? When used as Type MTW, conductor is suitable for use in wet locations or when exposed
To oil or coolant at temperatures not to exceed 60° C or dry locations at temperatures not to
Exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)
? Conductor temperatures not to exceed 105° C in dry locations when rated AWM and used as
Appliance wiring material. Voltage for all applications is 600 volts

STANDARDS & REFERENCES
Type THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable
ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification
A-A-59544 and requirements of the National Electrical Code. ® RoHS Compliant.

CONSTRUCTION
? Type THHN or THWN-2* or MTW copper conductors are annealed (soft) copper,
Insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a
Nylon (polyamide) or UL-listed equal jacket is applied
? Available in black, white, red, blue, green, yellow, brown, orange and grey; Some colors
Standard, some subject to economic order quantity
SPECIFICATIONS
? MTW or THHN or THWN-2:
Conductors shall be UL-listed Type MTW or THHN or THWN-2* gasoline and oil
Resistant II, suitable for operations at 600 volts as specified in the National Electrical
Code. ® Sizes 14 through 6 AWG shall be rated VW-1. Conductors shall be annealed
Copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion,
Moisture, gasoline and oil resistant nylon or listed equivalent, as manufactured by
Southwire Company or approved equal.
? AWM:
Conductors shall be UL-listed Type THHN or THWN-2* or MTW or AWM, suitable for
Operation at 600 volts at conductor temperatures not to exceed 105° C.

Building wire is generally used to carry electrical current to all external uses of power in a building or dwelling. This product is utilized in the construction of almost every industrial, residential and commercial building. The most popular type is THHN building wire.
THHN Wire stands for Thermoplastic High Heat-resistant Nylon coated. THHN can come in stranded or solid conductors depending on the size. It is either manufactured in copper or aluminum and covered in a PVC (polyvinyl chloride) insulation with a nylon jacket. THHN is UL listed with a rated 90 degrees Celsius in dry locations or 75 degrees Celsius in wet applications with a THWN rating. The vast majority of THHN building wire carries a dual rating on the cable marked THHN / THWN for both the wet and dry temperature rating. THHN building wire may also be used for wiring of machine tools, control circuits or on certain appliances.
THHN building wire has several main distinctions compared to other building wire products. THHN uses a thinner PVC insulation which is a key factor in terms of its electrical properties. This thinner insulation can often lead to a current leakage and even a breakdown during chemical or environmental exposure. The PVC insulation in THHN also creates a toxic smoke when burned therefore making it undesireable in certain applications.
THHN is not a very flexible product due to its nylon coating. This can often be a factor for many

We are China 600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 600v Cable Products

Low Voltage 600V Single Conductor Urd Cable

600V Triplex Conductor Urd Cable

Thhn/Tffn Inner Core Power and Control Tray Cable Tc Er Cable

UL 1569 Standard Mc Copper or Aluminum Conductor Aluminum Alloy Tape Armored Cable

600V Duplex Conductor Urd Cable

12/2 12/3 14/4 Thhn Cores Aluminum Armored Mc Cable

Popular Building Wire Products

Wholesale Price Thhn Al 8000 350 Mcm From Largest UL Cables Manufacturer

PVC Building Wire Thw Copper Wire

Electric Wire

Electrical Copper Wire, PVC Insulated Electric Building Wire for Construction.

Y/G PVC Insulated Cable 1C 25mm2 IEC 60227 Electrical Wire

Electric Home Wire

Popular Thhn/Thwn/Twn75/T90 Products

600V, Building Wire, Thhn/Thwn/Twn75/T90, 8AWG Construction Building Flexible Wire

Popular yifangcable Products

All Aluminium Alloy Conductor AAAC Cable Ash 150mm2

11kv 15kv Aluminum Conductor XLPE Mv ABC Cable 3X120+70mm2

Medium Voltage XLPE Insulated Cable

U1000 Rvfv Cable 4X240sqmm

Medium Voltage Aluminium Power Cables Na2xsy

Flexible Copper Wire Rubber Insulated Rubber Sheath H07rn-F Rubber Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION