600V Secondary Distribution Directly Buried Ud/Urd Aluminum Service Drop Cable
600V Secondary Distribution Directly Buried Ud/Urd Aluminum Service Drop Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messsenger.
ASTM B-230, B-231, B-232 and B-399 & ICEA S-76-474.
Specifications
Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | ||||||
Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
AAC NEURAL-MESSENGER | ||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 64 | 64 | 85 | 70 |
DachShund | 4 | 1 | 45 | 4 | 7 | 881 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 147 | 147 | 150 | 120 |
Bull | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 234 | 234 | 205 | 160 |
* Code Words For XLP Insulated Products Are Formed By Adding "/XLP" to the Conventional Code Words Above (e.g.-Chihuahua/XLP).+ Conductor Temperature of 90°C For XLP, 75°C For Poly; Ambient Temperature of 40°C; Emissivity 0.9; 2 ft./sec. Wind In Sun. |
Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | ||||||
Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | 1 | 45 | 6 | 6/1 | 1190 | 72 | 72 | 85 | 70 |
Shepherd | 6 | 7 | 45 | 6 | 6/1 | 1190 | 75 | 75 | 85 | 70 |
Eskimo | 4 | 1 | 45 | 4 | 6/1 | 1860 | 110 | 110 | 115 | 90 |
Terrier | 4 | 7 | 45 | 4 | 6/1 | 1860 | 115 | 115 | 150 | 120 |
Chow | 2 | 7 | 45 | 2 | 6/1 | 2850 | 176 | 176 | 150 | 120 |
Bull | 1/0 | 9 | 60 | 1/0 | 6/1 | 4380 | 280 | 280 | 205 | 160 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | |||||||
Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Insul. Thick. (mils) | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Chihuahua | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 65 | 65 | 85 | 70 |
Vizsla | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 68 | 68 | 85 | 70 |
Harrier | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 99 | 99 | 115 | 90 |
Whippet | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 103 | 103 | 115 | 90 |
Schnauzer | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 157 | 157 | 150 | 120 |
Heeler | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 250 | 250 | 205 | 160 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++ Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
(1)Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent
resistivity per ASTM B-399 for 6201.
(2)Conductor temperature of 90 Centgrade for XLPE, 75 Centgrade for PE; ambient temperatures of
40 Centgrade; emissivity 0.9; 2ft./sec/wind in sun.
We are China 600V Secondary Distribution Directly Buried Ud/Urd Aluminum Service Drop Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Service Drop Cable Products
Caai-S Cables Autoportantes Multi-Conductores De Aluminio.
Aluminio Autoportante Tipo Caai Cable De 3X50+1X16+Na35mm2
Popular Duplex Service Drop Cable Products
600V LDPE / HDPE / XLPE Insulation Secondary Ud Conductor Cable
0.6/1kv 3X50+54.6+1X16mm2 XLPE Aluminum Aerial Cable
Aluminum Duplex/Triplex Service Drop Cable XLPE Insulation ABC Cable 0.6/1kv
0.6/1kV 3X50+54.6+1X16mm2 XLPE Insulated Aluminum Aerial Cable
Aluminum Conductor XLPE/PVC Insulated Low Voltage Duplex Service Drop Cable
Secondary Conductor Aluminum Cable- (ABC cable)
Popular jytopcable Products
4 Core Aluminium Conductor Steel Wire Swa Armoured Power Cable
Flexible Cable Nyaf Cable, H07V-K Cable
Copper Conductor PVC Insulated PVC Sheathed Power Cable
Bare Conductor Galvanised Steel Wire Guy Wire Stay Wire to Bs183
450V Flame Retardant Control Cable
Bare Wire Factory for Electric Copper Wire Price
Popular Triplex Service Drop Cable Products
PVC Insulated Aerial Flexible Electrical ABC Cable
4/0AWG 600V XLPE Al Twisted Service Drop Cable Triplex Cable
Duplex Triplex Quadruplex Al XLPE ICEA S -76-474 Standard Service Drop Cable
PVC Insulated Aerial Electrical Cable with 0.6/1 Kv AAC Conductors Triplex Service Drop Cable
Aluminum Conductor XLPE Insulated Low Voltage Triplex Service Drop Cable
0.6kv/1kv Aerial Bunched Triplex Service Drop Cable 3/0 AWG Flustra
Tags: Aluminum Service Drop Cable, Duplex Service Drop Cable, jytopcable, Triplex Service Drop Cable