600V Thhn Wire with Nylon Jacket
600V Thhn Wire with Nylon Jacket image
Get Latest Price Request a quote
Quick Details
Product Details
APPLICATION Suitable for use as follows:
THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2;
When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90° C;
When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90° C or not to exceed 75° C when exposed to oil or coolant;
When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60° C or dry locations at temperatures not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)
Conductor temperatures not to exceed 105° C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts
STANDARDS & REFERENCE
THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.
CONSTRUCTION
THHN or THWN-2* or MTW copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-listed equal jacket is applied Available in black, white, red, blue, green, yellow, brown, orange, and gray; Some colors standard, some subject to economic order quantity
Conductor sizes 2 AWG and larger listed and marked sunlight-resistant in black only
SPECIFICATION
MTW or THHN or THWN-2
Conductors shall be UL-listed Type MTW or THHN or THWN-2* gasoline and oil resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. Sizes 14 through 1 AWG shall be rated VW-1, larger sizes shall be listed for CT use. Sizes 2 AWG and larger listed and marked sunlight-resistant in black only. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent
AWM
Conductors shall be UL-listed Type THHN or THWN-2* or MTW or AWM, suitable for
Operation at 600 volts at conductor temperatures not to exceed 105° C.
We are China 600V Thhn Wire with Nylon Jacket manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jytopcable Products
Acss/Aw Bare Conductor to ASTM Standards
Aerial Bundle Cable for Overhead Transmission Cabo Al Quadruplex
ASTM B232 Standard Aluminum Conductor Steel Reinforced Bare Conductor ACSR
4 Core Aluminum XLPE/PVC Insualted Swa Steel Wire Armoured Power Cable
High Voltage 26/35kv Aluminum Conducto XLPE Insulated Power Cable
Factory Guy Wire Galvanized Steel Wire Gsw to ASTM A475
Popular Thhn AWG 10 Products
Popular Thhn Cable Products
600V Thermoplastic Insulation/Nylon Sheath Aluminum Thhn Cable
4AWG 2AWG 1AWG Thhn Wire Electric Wire Copper PVC Nylon 600V UL Cable
Thhn Thwn Electric Wire Cable 4/0AWG 250mcm
600V Copper Wire PVC Insulated Thhn Building Cable
Nylon Sheathed Electric Copper Wire Thhn Thwn Cable
350mcm Copper Conductor PVC Insulated Nylon Jacket Thhn Wire 600V
Popular Thhn Wire Products
1 2 4 6 8 10 12 14 AWG Gauge Thhn Thwn Thwn-2 Wire Copper Electric Wire Power Cable 600V
PVC Insulated Aluminum Copper Conductor Electrical Wire Thhn Thwn Thwn-2 T90 Building Wire
Thhn Cable 12AWG Thhn Cable 14AWG Thhn 16AWG Wire
Thhn Thwn Wire PVC Insulated Building Wire
Tags: jytopcable, Thhn AWG 10, Thhn Cable, Thhn Wire
