66kv 110kv 132kv 220kv Copper Conductor 400mm 185mm2 240 Sq mm 50 Sq mm 50mm2 500mm2 Ehv Super High Voltage Power Cable

China 
                66kv 110kv 132kv 220kv Copper Conductor 400mm 185mm2 240 Sq mm 50 Sq mm 50mm2 500mm2 Ehv Super High Voltage Power Cable
              manufacture and supplier

66kv 110kv 132kv 220kv Copper Conductor 400mm 185mm2 240 Sq mm 50 Sq mm 50mm2 500mm2 Ehv Super High Voltage Power Cable image

Get Latest Price Request a quote

Basic Info.

Model NO.
EHV Cable

Wire Core Material
Bare Copper Wire

Certification
ISO, CCC

Model
Ehv Cable

Brand
Yifang

Standard
IEC 60884

Transport Package
Steel Drum

Specification
630mm2 500mm2 400mm2

Trademark
YIFANG

Origin
China

HS Code
8544492100

Production Capacity
10000m Per Week

Product Description

110kV 220kV EHV Super High Voltage Power Cable

Executive standards
Cross-linked PE insulated power cables for rated voltage 110kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 110kV and its Attachments in GB/T 11017, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840.

Cross-linked PE insulated power cables for rated voltage 220kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 220kV and its Attachments in GB/T 18890, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV and its Attachments in IEC 62067.

Cross-linked PE insulated power cables for rated voltage 500kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 500kV and its Attachments in GB/T 22078, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV and its Attachments in IEC 62067.

Cross-linked PE insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840.

Cross-linked PE insulated power cables for rated voltage 33kV should perform the rules of Cross-linked PE Insulated Power Cable for Rated Voltage 33kV and its Attachments in GB/T 12706, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 6kV up to 30kV in IEC 60502.
Main performance

  1. The rated voltage Uo/U of cables: 18/30kV, max. Voltage Um=33kV;

                                 38/66 or 48/66kV, max. Voltage Um=72.5kV;
                                 64/110kV, max. Voltage Um=126kV;
                                 76/132kV, max. Voltage Um=145kV;
                                 127/220kV, max. Voltage Um=252kV;
                                 290/500kV, max. Voltage Um=550kV.

  1. Permissible long-term working temperature of cable conductor 90ºC.

When the cable confronts short circuit within 5 seconds, the highest temperature of the conductor should not exceed 250ºC. When there exit line joints, the temperature of tin soldering ones should not exceed 120ºC, the temperature of crimping ones should not exceed 150ºC, and

  1. the temperature of electric or gas welding should not exceed 250ºC.
  2. When laying, the max. permissible bending radios should exceed 25D; After laying, the max. Permissible bending radios should exceed 23D.
  3. When laying, ambient temperature ≥0ºC (When the cable has to be laid under the ambient temperature below 0ºC, it is necessary to preheat the cable above 0ºC)
  4. When laying, the cable isn’t limited by disparity with the satisfaction of mechanical pressure, but it is not permissible to lay the cable in the iron pipe, nor the circular iron materials around fixed cables.

 

Type Description Application
Copper core Aluminum core
YJV, JYY YJLV, YJLY XLPE insulation PVC/PE sheath power cable Installation in the tube or channel, resistant against the damp environment and certain tension
YJSAV-Z YJLSAV-Z Vertical water blocking power cables with cross-linked PE insulated, copper wire shielded, al-plastics composite tape and PVC jacked Installation in the tube or channel, resistant against the damp environment and certain tension
YJSAY-Z YJLSAY-Z Vertical water blocking power cables with cross-linked PE insulated, copper wire shielded, al-plastics composite tape and PE jacked
YJLW02-Z YJLLW02-Z Vertical water blocking power cables with cross-lined PE insulated, corrugated aluminum and PVC jacked Installation in the tube or channel, available used in the damp environment, places with high level of underground water, and certain tension; specially used in the places with low corrosion and bearing certain mechanical force (such as bridge, vertical well and so on with the direct connection to transform); PE jacked with good capacity of anti-moisture.
YJLW03-Z YJLLW03-Z Vertical water blocking power cables with cross-lined PE insulated, corrugated aluminum and PE jacked

 

Type Description Application
Copper core Aluminum core
YJQ02-Z YJLQ02-Z Vertical water blocking power cables with cross-linked PE insulated, lead set and PVC jacked Installation in the tube or channel, available used in the damp environment, places with high level of underground water, certain tension and shock resistance; Specially used in places with heavy corrosion but without nitrate acid, acetic acid, organic matter (e.g. Peat), and strong alkali corrosion quality; certain mechanical force (tension, pressure, shock) available; PE jacked with good capacity of anti-moisture.
YJQ03-Z YJLQ03-Z Vertical water blocking power cables with cross-linked PE insulated, lead set and PE jacked

Note: 1. The table only lists the main types. According to the requirements of clients, the types of flame resistance, rat proof, and termite proof and son on, can also be produced, then the prefix of "ZC, WZDZB, FS, FY" should be added.

     2. The expressions of product symbols

     Cross-linked PE insulation – YJ             Copper conductor – T

     Aluminum conductor – L                    Winding copper wire shield – S

     Al-plastic composites – A       Lead set – Q

     Corrugated aluminum jack – LW       PVC outer sheath – V or 02

     PE outer sheath – Y or 03                   Vertical blocking structure – Z
 
     Rat proof – FS                  Termite proof – FY

     Flame resistance A, B, C – ZA, ZB, ZC

     Low smoke, zero halogen, fire resistant – WDZA, WDZB, WDZC

Product range
 

Type Rated voltage Uo/U KV Number of cores Nominal section mm2
YJV, YJLV, YJY, YJLY, YJSAV-Z, YJLSAV-Z, YJSAY-Z, YJLSAY-Z, YJLW02-Z, YJLLW02-Z,
YJLW03-Z, YJLLW03-Z,
YJQ02-Z, YJLQ02-Z,
YJQ03-Z, YJLQ03-Z
18/30 1 185, 240, 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500
38/66 48/66 1 240, 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500
64/110 1 240, 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500
76/132 1 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500, 3000
127/220 1 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500, 3000
290/500 1 300, 400, 500, 630, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500, 3000

Note: The aluminum conductor is not recommended concerning to cables for voltage exceeding 220kV.

Cable Construction
 

  1. The property of cable conductor is in accordance with the rules of GB/T 3956-2008. The cross-section below 800mm2 should be tight round winding conductor; above 1000mm2 should be segmentation conductor construction.

 

  1. Inner shield adopt the cross-linked semi-conductive shield materials to extrude over the conduct extremely smoothly.

 

  1. Insulation should adopt the extremely clean XLPE insulation materials, and triple extrude with outer shield tightly bonded.

 

  1. Outer shield should adopt cross-linked shield materials o extrude over insulation extremely smooth.

 

  1. Vertical water blocking layer and buffer layer should adopt semi-conductive water-proof tapes with strong capacity of water-proof to wrap between the outer shields and vertical water-proof layer.

 

  1. Vertical water-proof layer should adopt the al-plastic composites and iron jack should adopt corrugated aluminum or lead sheath, which can meet the capacity and screen of short circuit.

 

  1. Protection layer and corrosion resistance layer make sure the effective protection for the corrugated aluminum jack or lead sheath.

9. Outer jack should adopt PVC, PE or other relative sheath materials to extrude, in order to meet the electrical function and mechanical function. Other types of cables such as flame resistance, rat proof, low smoke and halogen also are produce as the different requirements of different places. The surface of outer sheath coasts or extrudes with a layer of continuously smooth semi-conductive materials as the pressure-resistant electrode of outer sheath.

Our company

Yifang Electric group mainly specialized in wire&cables,including designment,production and sale.

Products are mainly covering low,medium,high voltage(1KV to 220KV) XLPE Insulated power cable,PVC insulated power cable,ABC cable,building cable control cable,rubber cable welding cable Etc.

Our XLPE cable can be manufactured according to the company’s specification which is equivalent to IEC 60502,IEC60332,IEC60754. Some indexes are superior to above international standard.


Our certificate


FAQ
1.Q:Are you a factory or trading company? 
 A: Manufacturing base in Henan ,China, with more than 500 workers.

2.Q:How can I visit there? 
 A: Sure,If you need,we will arrange the driver to pick you up. 

3.Q:How can I get some samples? 
 A: Contact me on below,Determin sample and address for shipping.  

4.Q:Have you ever supplied cables to our country? 
 A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.

5.Q:What is your MOQ? 
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement. 

6. Q:When can I get the price? 
A: Usually quote within 6 hours after we get your inquiry. 

7.Q:How long is your delivery time?
 A: According to your order’s quantity.Usually our lead time is 3 – 20 working days.
 

We are China 66kv 110kv 132kv 220kv Copper Conductor 400mm 185mm2 240 Sq mm 50 Sq mm 50mm2 500mm2 Ehv Super High Voltage Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 110kv High Voltage Cable Products

110kv High Voltage XLPE Insulated Power Cable

110kv 220kv Ehv Super High Voltage Power Cable

Popular 220kv Hv Power Cable Products

110kv 220kv Ehv Super High Voltage Power Cable

Popular Ehv Power Cable Products

110kv 220kv Ehv Super High Voltage Power Cable

Popular yifangcable Products

Aluminum Triplex Service Drop ACSR Neutral Conductor Cockle

Low Voltage Aluminum Conductor AAC AAAC Aacsr ACSR Acar ACSR/Aw ASTM IEC GB DIN Standard ACSR Conductor DIN 48204 120/20

Nyy 1 / 2 / 3 / 4 / 5 / Core 061kv PVC Insulation Power Cable Nyy Cable Size Customized

600/1000V ABC Aerial Bundled Cables to BS 7870-5 (AL/XLPE)

7/12" Stay Wire 7/2.64mm BS183

Aluminum Alloy Conductor - AAAC Aster 34.4mm2

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION