70mm2 SD Cu'pvc Conductor

China 
                        70mm2 SD Cu'pvc Conductor
                      manufacture and supplier

70mm2 SD Cu'pvc Conductor image

Get Latest Price Request a quote

Quick Details

70mm2 SD Cu'pvc Conductor

Oeipower Jingguan

Xihari

ZnO

Round

High Voltage

Meidum

AC/DC System

Pole Line

Zinc Oxide Arrester

Distribution

Kv

Kv

Kv

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

85354000

Product Details

METAL OXIDE SURGE ARRESTER

Polymer housed for outdoor application

Features

Better Electrical performance & reliability
Ease of Installation-Light weight & smaller size
Better Operating conditions
Explosion & shatter proof & less mechanical
damage to nearby equipments
Better performance in polluted environment
Vandalism resistant
Free from Moisture ingress
Higher safety
Higher mechanical strength
Insensitive to UV radiation
High resistance to Ozone & Corona
Excellent Tracking resistance
Performance Data

System Voltage
Rated Voltage (kV):0.1-275
Nominal discharge current (kA)
High current capability (4/10us) kA
Energy Class :
Energy absorption Capability kJ/kV
Short Circuit (Pressure relief) kA:40
Standard in accordance with:IEC60099-4
Porcelain housed for outdoor application

 

For protection of transformer & switchgear.
Highly non-linear MOV.
Explosion Proof – Pressure Relief Design.
High energy handling capacity.
Glazed brown Porcelain Housing.
Corrosion proof Aluminum alloy metal flange.
Suitable for Ambient -400C to +550C.

manufactures effective surge protection device with the modern technology of highly non-linear Zinc
Oxide Varistor blocks and thus diverts natural lightning surge and switching surge to earth and simultaneously clip off
any follow on current. Our station class arresters are designed to provide maximum safety to personnel and sub-station
equipment even at the enormous short circuit duty. Research and Development is an ongoing process at Elektrolites
with the active collaboration of experts in the industry.
CONSTRUCTION & OPERATING PRINCIPLE

 

 Lightning Arrestors
 
11kV
 
 
 

No. DETAIL UNITS DATA
  Type   11kV gapless type metal oxide surge
arrester – Distribution class
1. Nominal  system  voltage kV 11
2. Highest system voltage kV 12
3. Basic Insulation Leve(BIL) kV 95
   
3.  Ratings and type of surge arrester
   
4. Specification to which surge arrester complies   IEC
600994
5. Rated voltage of surge arrester kV 10
6. Nominal, 8/20 µs, discharge current rating of
surge arrester
kA 10
7. Maximum continuous operating voltage of
surge arrester
kV 7.3
8. Gapless or gapped type metaloxide surge
arrester
  Gapless
9. Material of insulation   High temperature vulcanised silicon
rubber
10. Rated frequency of surge arrester Hz 50
11. Design altitude of surge arrester (above sea
level)
m 1 400m
12. Design ambient temperature of surge arrester oC 1 to40
13. Specific creepage distance of surge arrester .mm/kV 25
  Automatic earth lead disconnectors
requirements
   
14. Automatic earth lead disconnectors to be fitted Yes/No YES

 

 
 

15. Corrosion protection of metal and alloy parts:
galvanising specification and/or stainless steel grade
  To SABS 763, 316
  Tests    
16. Previous type test results/certificate to be
provided with bid
Yes/No Yes
17. Routine test results/certificate to be provided
on delivery
Yes/No Yes
18. Drawing showing dimensions of the arrestor to
be provided with the bid
Yes/No Yes
19. Minimum one minute wet power frequency
withstand voltage of external insulation of surge arrester housing
kV 28
20. Maximum steep current impulse residual
voltage for a 10 kA, 1/20 µs, discharge current
kV 50
21. Maximum lightning impulse residual voltage
for a 10 kA, 8/20 µs, discharge current
kV 40
22. Lightning, 1,2/50 µs, impulse withstand level
of external insulation of surge arrester housing
kV 95
23. Line discharge class rating   1
24. Long duration current, 2 000 µs, impulse
withstand
A 250 A
25. High current, 4/10 µs, impulse withstand kA 100 kA
26. Automatic earth lead disconnector to be tested
in accordance with IEC 600994
Yes/No Yes

 

 
 
 
 
 
 
 
 
 
 
33kV
 
 
 
 

S/N TECHNICAL DETAILS UNITS DATA
1. Type   33kV gapless type metal
oxide surge arrester –
Distribution class
2. Nominal  system  voltage kV 33
3. Highest system voltage kV 36
4. Power frequency Hz 50
5. Basic Insulation Leve(BIL) kV 170
   
3.  Ratings and type of surge arrester
   
6. Specification to which surge arrester complies   IEC 60099
7. Rated voltage of surge arrester kV 29
8. Nominal, 8/20 µs, discharge current rating of surge arrester kA 10
9. Maximum continuous operating voltage of surge arrester kV 22
10. Gapless or gapped type metaloxide surge arrester   Gapless
11. Insulation Material   Silicon rubber
12. Cantilever strength of surge arrester Nm 300
13. Rated frequency of surge arrester Hz 50
14. Design altitude of surge arrester (above sea level) m 1 400m
15. Design ambient temperature of surge arrester oC 1 to 40
16. Minimum phasetoground specific creepage distance of
surge arrester
.mm/kV 25
  Automatic earth lead disconnectors requirements    
17. Automatic earth lead disconnectors fitted Yes/No Yes
18. Corrosion protection of metal and alloy parts: galvanising   To  SABS 763, 316
         

 

 
 

  specification and/or stainless steel grade    
  Tests    
19. Previous Type Test reports/certificate  from recognized
authority to be provided with bid
Yes/No Yes
20. Minimum one minute wet power frequency withstand
voltage of external insulation of surge arrester housing
kV 70
21. Maximum steep current impulse residual voltage for a 10
kA, 1/20 µs, discharge current
kV 99.7
22. Maximum lightning impulse residual voltage for a 10 kA,
8/20 µs, discharge current
kV 91.8
23. Lightning, 1,2/50 µs, impulse withstand level of external
insulation of surge arrester housing
kV 170
24. Line discharge class rating Class 1
25. Long duration current, 2 000 µs, impulse withstand A 250 A
26. High current, 4/10 µs, impulse withstand kA 100 kA
27. Is the automatic earth lead disconnector tested in accordance
with IEC 600994?
Yes/No Yes

 

 
 
 
66kV
 
 
 
 

S/N TECHNICAL DETAILS UNITS DATA
1. Description   Station type lightning arrestor
complete with steel support structures.
2. Type   Zinc oxide gapless lightning
arrestor
  System parameters    
3. Nominal  system  voltage kV 66
4. Highest system voltage kV 72.5
5. Power frequency Hz 50
6. Type of system earthing   Effective/Non effective
7. Type of arrestor connection to system   Line to ground
   
3.  Ratings and type of surge arrester
   
8. Rated voltage of surge arrester kV rms 54
9. Nominal, 8/20 µs, discharge current rating of surge arrester kA peak 10
10. Maximum continuous operating voltage of surge arrester kV 43
11. Minimum one minute wet power frequency withstand voltage kVrms 140

 
 
151

 

 
 
 

  of external insulation of surge arrester housing    
12. Maximum steep current impulse residual voltage for a 2 kA,
30/60 µs, discharge current
kVpeak 104
13. Maximum lightning impulse residual voltage for a 10 kA, 8/20
µs, discharge current
kVpeak 127
14. Minimum lightning, 1,2/50 µs, impulse withstand level of
external insulation of surge arrester housing
  325
15. Line discharge class rating   2
16. Lighting arrestor counter, leakage current meter and their
accessories to be provided
Yes/No Yes
17. Gapless or gapped type metaloxide surge arrester   Gapless
18. Insulation Material   Porcelain
19. Cantilever strength of surge arrester Nm 3000
20. Rated frequency of surge arrester Hz 50
21. Maximum angle from vertical at which surge arrester is fully
functional
Deg 45
22. Design altitude of surge arrester (above sea level) m 1400 m
23. Design ambient temperature of surge arrester oC 1 to 40
24. Humidity % 85
25. Specific phasetoground creepage of surge arrester .mm/kV 25
26. Corrosion protection of metal and alloy parts: galvanising
specification and/or stainless steel grade
  to SABS 763 or 316 stainless
steel
27. Previous type test results/certificate to be provided with bid Yes/No Yes
28. Design drawings showing dimensions including foundations
and brochures to be provided with bid
Yes/No Yes
29. Quality Assurance certification to be provided with the bid Yes/No Yes
30. Routine test results/certificate to be provided on delivery Yes/No Yes
31. Galvanized steel support structures complete with bolts &
washers to be provided on delivery
Yes/No Yes
32. Applicable standard   IEC60099

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
152

 
 
 
 
88Kv
 
 
 
 

S/N TECHNICAL DETAILS UNITS DATA
33. Description   Station type lightning arrestor
complete with steel support structures.
34. Type   Zinc oxide gapless lightning
arrestor
  System parameters    
35. Nominasystem  voltage kV 88
36. Highest system voltage kV 100
37. Power frequency Hz 50
38. Type of system earthing   Effective/Non effective
39. Type of arrestor connection to system   Line to ground
   
3.  Ratings and type of surge arrester
   
40. Rated voltage of surge arrester kV rms 84
41. Nominal, 8/20 µs, discharge current rating of surge arrester kA peak 10
42. Maximum continuous operating voltage of surge arrester kV 67
43. Minimum one minute wet power frequency withstand voltage
of external insulation of surge arrester housing
kVrms 185
  Maximum steep current impulse residual voltage for a 2 kA, kVpeak 188
  30/60 µs, discharge current    
45. Maximum lightning impulse residual voltage for a 10 kA, 8/20
µs, discharge current
kVpeak 218
46. Minimum lightning, 1,2/50 µs, impulse withstand level of
external insulation of surge arrester housing
  450
47. Line discharge class rating   2
48. Lighting arrestor counter, leakage current meter and their
accessories to be provided
Yes/No Yes
49. Gapless or gapped type metaloxide surge arrester   Gapless
50. Insulation Material   Porcelain
51. Cantilever strength of surge arrester Nm 3000
52. Rated frequency of surge arrester Hz 50
53. Maximum angle from vertical at which surge arrester is fully
functional
Deg 45
54. Design altitude of surge arrester (above sea level) m 1400 m
55. Design ambient temperature of surge arrester oC 1 to 40
56. Humidity % 85
57. Specific phasetoground creepage of surge arrester .mm/kV 25
58. Corrosion protection of metal and alloy parts: galvanising
specification and/or stainless steel grade
  to SABS 763 or 316 stainless
steel
59. Previous type test results/certificate to be provided with bid Yes/No Yes
60. Design drawings showing dimensions including foundations
and brochures to be provided with bid
Yes/No Yes
61. Quality Assurance certification to be provided with the bid Yes/No Yes
62. Routine test results/certificate to be provided on delivery Yes/No Yes
63. Galvanized steel support structures complete with bolts &
washers to be provided on delivery
Yes/No Yes
64. Applicable standard   IEC60099

 
 
 
 
 
 
 
 
 

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Lightning
Protective Device
Power Surge
Surge Protection
Arrester
Surge Protector
View More 

We are China 70mm2 SD Cu'pvc Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular jgtrade1 Products

Fuse Cutout, Drop out Fuses 60kv 100A

Verification of Dimensions

Monkey Head Grounding Wire

Soother for ACSR Conductor

Hy5ws-12.7/50 Zinc-Oxide Arrester

Fuse Cutout, Drop out Fuses 15kv 200A

Popular Lightning Arrester Products

Yh10W-48, Sharp Head 10kv 48ka Surge Arrester

Polymer Fuse Cutout 6kv 200A

220KV Porcelain Housed Station Surge Arrester

Polymeric Porcelain Gapless Zinc Oxide Lightning Arrester with Grading Ring

Hy5wz-3.8/13.5 Zinc-Oxide Arrester

Polymer Fuse Cutout, Drop out Fuses 15 Kv 100A 001

Popular Lightning Arrestors Products

33kv Fuse Element 5A Rating

Yh10W5-18 OEM Composite ZnO Moa Compound Shell Lightning Arrestor

Wholesale High Voltage Porcelain Metal Oxide Lightning Arrestors Surge Arresters

110kv Lighting Arrester

Yh10W-13, Sharp Head 18kv 10ka Surge Arrester

Auto Re-Closer

Popular Surge Arrester Products

Porcelain Housed Metal Oxide Lightning Arrester / Surge Arrester

High -Voltage Isolate Switch 60kv 1250A

Silicon Rubber Lighting Arresters 3kv/Surge Protector 10ka

Polymer Housed Surge Arrester With External Gap B

11kv Silicone Rubber Lightning Arrester

Xirui Factory Bulk 500kv Substation Outdoor Lightning Surge Arrester

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION