72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw

China 
                72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw
              manufacture and supplier

72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw image

Get Latest Price Request a quote

Basic Info.

Model NO.
BRDLW-72.5-1250-4

Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer

Brand
Ville

Material
Porcelain

Structure
Bushing Insulator

Type
B Type Insulator

Connection Method
Trough Type

Size of Bearing Capacity
5000n

Color
Brown

Enter Attribute Here (e.g.: Size)
Enter Value Here (e.g.: 12 Inches)

Voltage
72.5kv

Current
630~1250A

Shape
Short Tail Bushing

Transport Package
Wooden Cases

Specification
IEC

Trademark
VILLE

Origin
Made in China

HS Code
85

Production Capacity
50, 000 PCS/Year.

Product Description

Technical parameters:

Main properties
electric properties 
System nominal voltage Un(Kv) 35 66 110 132 150 220
Rated voltage Ur(Kv) 40.5 72.5 126 145 170 252
60s power frequency withstand voltage: Dry kv 95 147 230 275 325 460
Wet Kv 80 140 230 275 325 460
Lightning impulse withstand voltage chopped wave Full wave Kv(peak) 200 325 550 650 750 1050
Kv(peak)   375 635 750 865 1210
Operating impulse withstand voltage(dry or wet)                                      850
dielectric dissipation factor                      tanδ (20ºC temperature)Max. Ur:0.004
increment 1.05Ur/√3-Ur:0.0005
Ur Partial discharge under voltage ≤5pC
1.5Ur Partial discharge under voltage ≤10pC

 

Bending testing load
Rated voltage Ur(Kv) Bending testing load(N)
Rated current Ir(A)
≤800 800-1600 1600-2500 ≥3150
≤52 1250 2000 2000 2500
72.5 1250 1250 4000 4000
126-170 3150 4000 4000 4000
252 4000 5000 5000 5000

 

other properties
Item# Testing performance index
1 The bushing can withstand the gauge pressure of the sealing test at 0.2MPa  no leakage
2 interior tranformer oil Pressure value(Kv) ≥55
Dielectric loss factor tanδ(90ºC) ≤0.004
Mico water(μg/g) ≤10
Chromatography Acetylene(μL/L) 0
Hydrogen(μL/L) ≤30
Total hydrocarbons(μL/L) ≤9
3 Measurement of Dielectric Loss Factor of Terminal to earth under 2kV voltage ≤0.02

 

Type designation
BRDLW- (rated voltage:kV)/ (rated current:A)- (Antifouling grade)
BR-OIP Condenser transformer bushing,OIP Condenser wall bushing represent as CR
D-Short tail bushing,if no “D” it should be Medium-short tail bushing
L:can install CT
W:Antifouling type,3 means creepage distance is 25mm/kV,4 means creepage distance is 31mm/Kv
 
72.5Kv/630~1250A OIP Condenser transformer bushing(Draw lead)
Code Type Rated voltage Kv Rated current
A
Main Dimensions(mm) Creepage distance MASS KG
L L1 L2 L3 L4 L5 D1 D2 D3 d1 d2 d3 d4 A Z X
BR4134A BRDLW-72.5/630-3 72.5 630 1955 1650 700 670 400 35 180 138 280 28 35 18 14 40 60 120 1900 88
BR4144A BRDLW-72.5/630-4 72.5 630 2010 1705 755 670 400 35 180 138 280 28 35 18 14 40 60 120 2250 92
BR4135A BRDLW-72.5/630-3 72.5 630 2055 1750 700 770 500 35 180 138 280 28 35 18 14 40 60 120 1900 88
BR4145A BRDLW-72.5/630-4 72.5 630 2110 1805 755 770 500 35 180 138 280 28 35 18 14 40 60 120 2250 86
BR4143A BRDLW-72.5/630-4 72.5 630 1910 1605 755 570 300 35 180 138 280 28 35 18 14 40 60 120 2250 88
BR4132A BRDLW-72.5/630-3 72.5 630 1820 1615 700 535 265 35 180 138 280 28 35 18 14 40 60 120 1900 81
BR4142A BRDLW-72.5/630-4 72.5 630 1875 1570 755 535 265 35 180 138 280 28 35 18 14 40 60 120 2250 87
BR4130A BRDLW-72.5/630-3 72.5 630 1585 1280 700 300 30 35 180 138 280 28 35 18 14 40 60 120 1900 75
BR4140A BRDLW-72.5/630-4 72.5 630 1640 1335 755 300 30 35 180 138 280 28 35 18 14 40 60 120 2250 80
BR4154A BRDLW-72.5/630-4 72.5 630 2105 1800 850 670 400 35 180 138 280 28 35 18 14 40 60 120 2610 98
BR4234A BRLW-72.5/1250-3 72.5 1250 2100 1805 700 800 450 40 200 160 350 36 48 24 18 50 110 145 1900 109
BR4244A BRLW-72.5/1250-4 72.5 1250 2155 1860 755 800 450 40 200 160 350 36 48 24 18 50 110 145 2250 118
BR4235A BRDLW-72.5/1250-3 72.5 1250 2100 1705 700 800 500 40 200 160 350 36 48 24 18 50 110 140 1900 106
BR4245A BRDLW-72.5/1250-4 72.5 1250 2155 1860 755 800 500 40 200 160 350 36 48 24 18 50 110 140 2250 114

Other HV bushing reference:


Package reference:

Ville Electric Company will keep up with the century, the epoch,

Sincerely look forward to your cooperation and win-win!

Create brilliant!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China 72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw Products

  • No related articles
  • Popular Bushing Products

    Br52 Series 126kv/1250A Oip Condenser Transformer Bushing (draw lead)

    Bfwc-24/630~10000-4 24kv C Type Transfomer Bushing (CONDUCTOR STRUCTURE)

    2023 China Supplier 1.2kv 420A Molded LV Bushings Tri-Clamp Bushing

    150*200 Transformer Bushings Through Hole with Busbar Smooth Shedless Insulation Epoxy Wall Bushing 12kv

    52KV 630A /P3 transformer bushing EN50180

    Lyc145 12kv Epoxy Resin Insulation Wall Through Bushing 110*180*190 for Switchgear

    Popular cnville Products

    Switch, Hv Earthing Switch; Earthing Switch

    Mobile Substation 66/20 Kv/0.4kv 10 Mva with Truck Assembled Movable Transformer Power Station with 20kv Gis Metal Enclosure

    4.2mva 10kv Electric Arc Furnace Transformer Replacement

    Cj/Srcj Outdoor Disconnect Switch Electromotor Operation Mechanism

    Transformer Swich Oltc Multi-Level Coarse Voltage-Regulating on Load Tap Changer for High Voltage Special Transformer

    Lw8-40.5 Sf6 Circuit Breaker; Outdoor AC Hv Sf6 Circuit Breaker 1250A 31.5ka

    Popular Transformer Bushing Products

    Factory Sales DIN 42530 Porcelain Bushing Insulator

    Vintage Brown Ceramic 38kv Transformer Porcelain Bus Support Bushing

    China Manufacturer Power Transformer Bushing Electric 1.2kV Epoxy Resin Bushing

    Bfwc-40.5/630~10000-4 40.5kv C Type Transfomer Bushing (CONDUCTOR STRUCTURE)

    Transformer Bushings in Low Voltage

    LV Transformer Bushing Insulators for Transmission Line

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION