95mm2 Bare Aluminum Conductor
95mm2 Bare Aluminum Conductor image
Get Latest Price Request a quote
Basic Info.
Product Description
Capacity: 2000ton/month
Delivery Length: accord with the request
Min.Order Qty : 1km
Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises.
AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
Construction
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
AAC with IEC61089 Standard | ||||||||
Cross Section | Number of Stranding Wires | Diameter | Linear Mass | Rated Strength | Max.D.C. Resistance | |||
Wires | Conductor | |||||||
mm 2 | – | mm | mm | kg/km | kN | Ω/km | ||
10 | 7 | 1.35 | 4.05 | 27.4 | 1.95 | 2.8633 | ||
16 | 7 | 1.71 | 5.12 | 43.8 | 3.04 | 1.7896 | ||
25 | 7 | 2.13 | 6.4 | 68.4 | 4.5 | 1.1453 | ||
40 | 7 | 2.7 | 8.09 | 109.4 | 6.8 | 0.7158 | ||
63 | 7 | 3.39 | 10.2 | 172.3 | 10.39 | 0.4545 | ||
100 | 19 | 2.59 | 12.9 | 274.8 | 17 | 0.2877 | ||
125 | 19 | 2.89 | 14.5 | 343.6 | 21.25 | 0.2302 | ||
160 | 19 | 3.27 | 16.4 | 439.8 | 26.4 | 0.1798 | ||
200 | 19 | 3.66 | 18.3 | 549.7 | 32 | 0.1439 | ||
250 | 19 | 4.09 | 20.5 | 687.1 | 40 | 0.1151 | ||
315 | 37 | 3.29 | 23 | 867.9 | 51.97 | 0.0916 | ||
400 | 37 | 3.71 | 26 | 1102 | 64 | 0.0721 | ||
450 | 37 | 3.94 | 27.5 | 1239.8 | 72 | 0.0641 | ||
500 | 37 | 4.15 | 29 | 1377.6 | 80 | 0.0577 | ||
560 | 37 | 4.39 | 30.7 | 1542.9 | 89.6 | 0.0515 | ||
630 | 61 | 3.63 | 32.6 | 1738.3 | 100.08 | 0.0458 | ||
710 | 61 | 3.85 | 34.6 | 1959.1 | 113.6 | 0.0407 | ||
800 | 61 | 4.09 | 36.8 | 2207.4 | 128 | 0.0361 | ||
900 | 61 | 4.33 | 39 | 2483.3 | 144 | 0.0321 | ||
1000 | 61 | 4.57 | 41.1 | 2759.2 | 160 | 0.0289 | ||
1120 | 91 | 3.96 | 43.5 | 3093.5 | 179.2 | 0.0258 | ||
1250 | 91 | 4.18 | 46 | 3452.6 | 200 | 0.0231 | ||
1400 | 91 | 4.43 | 48.7 | 3866.9 | 224 | 0.0207 | ||
1500 | 91 | 4.58 | 50.4 | 4143.1 | 240 | 0.0193 | ||
AAC with DIN48201 Standard | ||||||||
Code Number | Calculated Cross Section | No./Dia.of Stranding Wire | Overall Diameter | Linear Mass | Calculated Breaking Load | Max.D.C. Resistance | ||
mm² | mm² | mm | mm | kg/km | daN | Ω/km | ||
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 | ||
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 | ||
35 | 34.36 | 7/2.50 | 7.5 | 94 | 585 | 0.8332 | ||
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 | ||
50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 | ||
70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 | ||
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 | ||
120 | 117 | 19/2.80 | 14 | 322 | 1910 | 0.2459 | ||
150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 | ||
185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 | ||
240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 | ||
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 | ||
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.0722 | ||
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.0578 | ||
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 | ||
800 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.0361 | ||
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.029 | ||
AAC with BS 215 Standard | ||||||||
Code Name | Nominal Cross Section | No./Dia.of Stranding Wires | Overall Diameter | Approx. Weight | Max.D.C Resistance of Conductor | Calculated Breaking Load | Final Modulus of Elasticity | Coefficient of Linear Expansion |
mm 2 | No./mm | mm | kg/km | ohm/km | daN | hbar | ||
Midge | 22 | 7/2.06 | 6.18 | 64 | 1.227 | 399 | 5900 | 23 x 10 -6 |
Aphis | 25 | 3/3.35 | 7.2 | 73 | 1.081 | 411 | 5900 | 23 x 10 -6 |
Gnat | 25 | 7/2.21 | 6.6 | 73 | 1.066 | 459 | 5900 | 23 x 10 -6 |
Weevil | 30 | 3/3.66 | 7.9 | 86 | 0.9082 | 486 | 5900 | 23 x 10 -6 |
Mosquito | 35 | 7/2.59 | 7.8 | 101 | 0.7762 | 603 | 5900 | 23 x 10 -6 |
Ladybird | 40 | 7/2.79 | 8.4 | 117 | 0.6689 | 687 | 5900 | 23 x 10 -6 |
Ant | 50 | 7/3.10 | 9.3 | 145 | 0.5419 | 828 | 5900 | 23 x 10 -6 |
Fly | 60 | 7/3.40 | 10.2 | 174 | 0.4505 | 990 | 5900 | 23 x 10 -6 |
Bluebottle | 70 | 7/3.66 | 11 | 202 | 0.3881 | 1134 | 5900 | 23 x 10 -6 |
Earwing | 75 | 7/3.78 | 11.4 | 215 | 0.3644 | 1194 | 5900 | 23 x 10 -6 |
Grasshopper | 80 | 7/3.91 | 11.7 | 230 | 0.3406 | 1278 | 5900 | 23 x 10 -6 |
Clegg | 90 | 7/4.17 | 12.5 | 262 | 0.2994 | 1453 | 5900 | 23 x 10 -6 |
Wasp | 100 | 7/4.39 | 13.17 | 290 | 0.2702 | 1600 | 5900 | 23 x 10 -6 |
Beetle | 100 | 19/2.67 | 13.4 | 293 | 0.2704 | 1742 | 5600 | 23 x 10 -6 |
Bee | 125 | 7/4.90 | 14.7 | 361 | 0.2169 | 1944 | 5900 | 23 x 10 -6 |
Cricket | 150 | 7/5.36 | 16.1 | 432 | 0.1818 | 2385 | 5900 | 23 x 10 -6 |
Hornet | 150 | 19/3.25 | 16.25 | 434 | 0.1825 | 2570 | 5600 | 23 x 10 -6 |
Caterpillar | 175 | 19/3.53 | 17.7 | 512 | 0.1547 | 2863 | 5600 | 23 x 10 -6 |
Chafer | 200 | 19/3.78 | 18.9 | 587 | 0.1349 | 3240 | 5600 | 23 x 10 -6 |
Spider | 225 | 19/3.99 | 20 | 652 | 0.1211 | 3601 | 5600 | 23 x 10 -6 |
Cockroach | 250 | 19/4.22 | 21.1 | 731 | 0.1083 | 4040 | 5600 | 23 x 10 -6 |
Butterfly | 300 | 19/4.65 | 23.25 | 888 | 0.08916 | 4875 | 5600 | 23 x 10 -6 |
Moth | 350 | 19/5.00 | 25 | 1027 | 0.07711 | 5637 | 5600 | 23 x 10 -6 |
Drone | 350 | 37/3.58 | 25.1 | 1029 | 0.07741 | 5745 | 5600 | 23 x 10 -6 |
Locust | 400 | 19/5.36 | 26.8 | 1179 | 0.0671 | 6473 | 5600 | 23 x 10 -6 |
Centipede | 400 | 37/3.78 | 26.46 | 1145 | 0.06944 | 6310 | 5600 | 23 x 10 -6 |
Maybug | 450 | 37/4.09 | 28.6 | 1342 | 0.05931 | 7401 | 5600 | 23 x 10 -6 |
Scorpion | 500 | 37/4.27 | 29.9 | 1460 | 0.05441 | 7998 | 5600 | 23 x 10 -6 |
Cicada | 600 | 37/4.65 | 32.6 | 1733 | 0.04588 | 9495 | 5600 | 23 x 10 -6 |
Tarantula | 750 | 37/5.23 | 36.6 | 2191 | 0.03627 | 12010 | 5600 | 23 x 10 -6 |
AAC with CSA C49 Standard | ||||||||
Code Name | KCMIL or AWG | Cross Section of Aluminum | Size | Total Mass | Rated Tensile Strength | Max.D.C. Resistance | ||
No.of Wires | Dia.of Wires | Dia.of Conductor | ||||||
mm² | – | mm | mm | kg/km | kN | Ω/km | ||
Anemone | 874.5 | 443.12 | 37 | 3.9 | 27.3 | 1223 | 72.9 | 0.06509 |
Cockscomb | 900 | 456.04 | 37 | 3.96 | 27.72 | 1259 | 75.2 | 0.06324 |
927.2 | 469.82 | 37 | 4.02 | 28.14 | 1297 | 77.5 | 0.06139 | |
Magnolia | 954 | 483.4 | 37 | 4.08 | 28.56 | 1334 | 79.8 | 0.05966 |
Hawkweed | 1000 | 506.71 | 37 | 4.18 | 29.26 | 1399 | 83.8 | 0.05692 |
Bluebell | 1033.5 | 523.68 | 37 | 4.25 | 29.75 | 1445 | 86.6 | 0.05507 |
1100 | 557.38 | 61 | 3.41 | 30.69 | 1541 | 94.7 | 0.05182 | |
Marigold | 1113 | 563.97 | 61 | 3.43 | 30.87 | 1559 | 95.8 | 0.05121 |
Hawthorn | 1192.5 | 604.25 | 61 | 3.55 | 31.95 | 1670 | 103 | 0.0478 |
1200 | 608.05 | 61 | 3.56 | 32.04 | 1681 | 103 | 0.0475 | |
Narcissus | 1272 | 644.54 | 61 | 3.67 | 33.03 | 1782 | 110 | 0.04481 |
1300 | 658.72 | 61 | 3.71 | 33.39 | 1821 | 112 | 0.04385 | |
Columbine | 1351.5 | 684.82 | 61 | 3.78 | 34.02 | 1893 | 113 | 0.04218 |
1400 | 709.39 | 61 | 3.85 | 34.65 | 1961 | 117 | 0.04072 | |
Carnation | 1431 | 725.1 | 61 | 3.89 | 35.01 | 2004 | 120 | 0.03983 |
1500 | 760.07 | 61 | 3.98 | 35.82 | 2101 | 125 | 0.038 | |
Gladiolus | 1510.5 | 762.72 | 61 | 3.99 | 35.91 | 2110 | 123 | 0.0379 |
Coreopsis | 1590 | 805.67 | 61 | 4.1 | 36.9 | 2227 | 133 | 0.03585 |
1600 | 810.74 | 61 | 4.11 | 36.99 | 2241 | 134 | 0.03563 | |
1700 | 861.41 | 61 | 4.24 | 38.16 | 2381 | 142 | 0.03353 | |
1800 | 912.08 | 91 | 3.57 | 39.27 | 2524 | 155 | 0.0317 | |
Cowslip | 2000 | 1013.42 | 91 | 3.77 | 41.47 | 2804 | 168 | 0.02853 |
Sagebrush | 2250 | 1140.1 | 91 | 3.99 | 43.89 | 3155 | 188 | 0.02536 |
2435.6 | 1234.14 | 91 | 4.16 | 45.76 | 3415 | 204 | 0.02343 | |
Lupine | 2500 | 1266.78 | 91 | 4.21 | 46.31 | 3505 | 209 | 0.02283 |
Bitterroo | 2750 | 1393.45 | 91 | 4.42 | 48.62 | 3856 | 230 | 0.02075 |
3000 | 1520.13 | 91 | 4.61 | 50.71 | 4207 | 251 | 0.01902 | |
3007.7 | 1524.03 | 91 | 4.62 | 50.82 | 4217 | 252 | 0.01897 | |
3500 | 1773.49 | 91 | 4.98 | 54.78 | 4908 | 292 | 0.0163 | |
3640 | 1844.42 | 91 | 5.08 | 55.88 | 5104 | 304 | 0.01568 |
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
We are China 95mm2 Bare Aluminum Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 95mm2 Bare Aluminum Conductor Products
Popular Aluminum Conductor Products
50mm2 Cu/Al Conductor Bare Overhead Conductor
AAC All Aluminum Conductor Bare Conductor IEC ASTM Standard
Aaaac Aluminum Conductor Overhead Cable
ACSR Conductor with IEC61089 Standard
All Anuminium Wire Stranded Conductor ASTM Standard
Popular Conductor Products
Duplex Service Drop Aluminium Conductor
IEC/DIN Standard AAAC 185mm2 Conductor Aluminum Allloy Bare Conductor
Factory Price Copper Wire Flexible Cable PVC Insulated Electrical/Electric Power Wire Cable
ACSR AAC AAAC with Safe Standard and Certificate
Popular jpcable99 Products
Overhead Bare Cable Aluminium Conductor Steel Reinforced Hare
Best Quality ACSR Bare Conductor for Sale
Low Voltage PVC Insulated 4 Core Power Cable
China Good Supplier Aluminum Core XLPE Insulated ABC Overhead Cable
Bare Aluminium Stranded Cable AAC ACSR
300/500V 450/750V Copper Core PVC Insulated Building Electrical Wire
Tags: 95mm2 Bare Aluminum Conductor, Aluminum Conductor, Conductor, jpcable99