ABC Aerial Bundle Cable for Overhead Transmission Line
ABC Aerial Bundle Cable for Overhead Transmission Line image
Get Latest Price Request a quote
Quick Details
Product Details
Specification: Aerial Bundle Cable
Standard: IEC228, IEC209, IEC60502
Voltage: 0.6/1 KV
Conductor: Aluminum conductor, aluminum alloy conductor, AAC, ACSR, AAAC
Insulation: HDPE, XLPE, PVC
Application: New type of Aerial Bundle Cable for Power transmission, used for rebuilding of urban and forest regions, which can improve safety and reliance of electrified wire netting.
ABC aerial bundle cable; Service Drop Cable
1 The basic construction is as follows:
three power cores consisting of standard aluminum conductors, insulated with XLPE
insulation + One sheath lighting aluminum conductor with XLPE insulation (optional) + One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanized steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
2 Application
To be used at cottages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLPE) insulated conductors.
It meets or exceeds the following specifications:
2.1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2.2. Aluminum Conductors, Concentric-Lay-Stranded.
2.3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
2.4. Concentric-Lay-Stranded 6201-T81 Conductors
2.5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
3.Types (ABC Aerial cable with ACSR messenger Core)
| Nominal cross-section area (mm2) | Conductor structure | Insulation material | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Approx.weight (kg/km) | Packing meters per drum | ||
| Phase (Compacted AL) | Neutral(bare ACSR) | |||||||
| (No./mm) | Aluminum (No./mm) | Steel (No./mm) | ||||||
| 1×16+16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
| 1×25+25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000 | |
| 1×35+35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
| 1×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
| 1×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 27.6 | 528.2 | 250-3000m | |
| 2×16+16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 14.2 | 187.6 | 250-4000m | |
| 2×25+25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
| 2×35+35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
| 2×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
| 2×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 30.5 | 850.9 | 250-3500m | |
| 3×70+70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
| 3×95+95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m | |
Parameter of ABC cable
| Code Word | Phase Conductor | Neutral | Complete Cable | DC Resistance at 20°C (ohm/kft) |
Inductive Reactance (ohm/kft) |
Ampacity* (90°C) |
||
| Size (# of wires) |
Insulation Thickness (inch) |
Size (Stranding) |
Overall Diameter (inch) |
Cable Weight (lb/kft) |
||||
| Shepherd/XLP | 6 (7) | 0.045 | 6 (6/1) | 0.47 | 77 | 0.661 | 0.029 | 95 |
| Retriever/XLP | 6 (7) | 0.060 | 6 (6/1) | 0.50 | 85 | 0.661 | 0.031 | 95 |
| Terrier/XLP | 4 (7) | 0.045 | 4 (6/1) | 0.57 | 116 | 0.416 | 0.028 | 125 |
| Yorkshire/XLP | 4 (7) | 0.060 | 4 (6/1) | 0.60 | 125 | 0.416 | 0.029 | 125 |
| Chow/XLP | 2 (7) | 0.045 | 2 (6/1) | 0.70 | 177 | 0.261 | 0.027 | 165 |
| Labrador/XLP | 1 (19) | 0.060 | 1 (6/1) | 0.81 | 231 | 0.207 | 0.027 | 180 |
| Bloodhound/XLP | 1/0 (7) | 0.060 | 1/0 (6/1) | 0.89 | 285 | 0.164 | 0.028 | 220 |
| Bull/XLP | 1/0 (19) | 0.060 | 1/0 (6/1) | 0.89 | 285 | 0.164 | ||
We are China ABC Aerial Bundle Cable for Overhead Transmission Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
0.6/1 Kv NFC 33-209 ABC Cable From Luxing Cable Factory
IEC 61089 AAC/ACSR/AAAC/ABC Bare All Aluminium Conductor
XLPE Insulation Aerial Bundle 15 Kv ABC Cable for Power Transmission
ABC Cable 600/1000V 25mm ABC Cable
0.6/1kv 4 Core ABC Aerial Bundle Cable 3*70+54.6mm2
0.6/1kv ACSR AAC AAAC Conductor XLPE Insulation Aerial Bounded Cable
Popular Aerial Bundle Cable Products
Duplex Service Dropcable, ABC Cable 70sqmm
0.6/1kv Overhead XLPE Insulated ABC Cable for Power Transmission
LV 2 Core 2*50mm2 Insulated ABC Cable Hot Sale
Overhead Cable 3+1 ABC XLPE Alumimium Core Conductor Cable
Aluminum Conductor XLPE Overhead Aerial Bundled ABC Cable
Popular Bundle Cable Products
Electrical Cable XLPE Insulation Aluminum Conductor ABC Aerial Bunch Cable
ABC Cable Phase+Supporting with Sans1418 Standard
ABC Service Drop Cable 1*6+6AWG ABC Cable Supplier
High Quality Aerial Bundle 0.6kv 70mm2 95mm2 Cable
Best Price Hot Sale Aerial Bundle Cable Three Core
LV and Mv Aerial Cable Covered Electrical/Electric Power Cable
Popular jytopcable Products
500V 6mm Twin and Earth Cable, Twin & Earth Cable
450/750V Ydyp Wire and Cable 2X1.5mm
300/500V Nym-J Cable Nym-O Cable. Nym Manufacturer
18/30kv Copper XLPE Power Cable 3X185mm2
PVC Insulated Building Wire with Solid or Stranded Conductor
Al Conductor XLPE Insulated Cable Al/XLPE/PVC Cable
Tags: ABC Cable, Aerial Bundle Cable, Bundle Cable, jytopcable