Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp

China 
                Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp
              manufacture and supplier

Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp image

Get Latest Price Request a quote

Basic Info.

Model NO.
JBTLY

Usage
Electrical Appliance

Material
Copper-Aluminum Alloy

Type
Wedge-Shaped

Defense
Durable and Practical

Transport Package
Material Flow

Specification
10-400mm² 90*75*75mm

Trademark
CNKC

Origin
China

Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
50.00cm * 40.00cm * 30.00cm

Package Gross Weight
20.000kg

Product Description

Product Description

The parallel groove clamp is the most widely used power connection connector at present, the purpose is to connect two power transmission lines, so that the power transmission can continue. The power fitting is a weak link in the transmission and distribution line, and has high requirements for resistance. If the resistance is too large, the heating phenomenon during the operation of the line will obviously lead to the burning and fusing of the line, which will cause large-scale power outages and cause serious damage. Economic losses.
The parallel groove clamp is used for the connection of small and medium section aluminum stranded wire or steel core aluminum stranded wire and the steel stranded wire of the overhead lightning arrester at the position that does not bear the tension, and also used for the jumper connection of non-linear towers. Power engineering materials (fittings) are mainly used for connecting wires to connect to each other in power line engineering.
PGA series torque energy-saving parallel groove clamp is a brand-new non-load-bearing connection fittings, which are mainly used in power transmission, substation, and distribution line systems, and play the role of wire connection and jumper connection. The special alloy with high strength, high conductivity and intermediate electrode potential is processed by special process, and has good mechanical and electrical properties.

Technical parameters and structure dimensions

Product features and Installation matters

Structural features:
1. Light weight (weight ratio of the crimping sleeve to the weight of the grooved wire clamp = 1:8.836)
2. Less specifications, easy to carry, reduce labor intensity of construction personnel
3. Less construction time and convenient live work
4. Construction quality assurance (hydraulic clamp)
5. No need to apply anti-oxidant protective oil
Installation matters:
1. The degree of contamination of the contact surface when installing the parallel groove wire clip has a certain influence on the contact resistance. Before installing the wire clip, ensure that the wire groove is clean.
2. In the contact form of the parallel groove wire clip, the larger the contact area, the lower the contact resistance. When designing the wire clip, try to use surface contact and increase the contact area.
3. When the parallel groove clamp is installed, the greater the contact pressure, the smaller the contact resistance. Choose standard parts with well-processed and uniform coating, and apply conductive grease during installation, which can effectively improve the contact performance of the parallel groove clamp and reduce the contact resistance.

Product reliability

From the characteristics of metal materials, we know that under the condition of stress, the wire will inevitably produce a certain amount of creep, which is more serious in the parallel groove clamp with high local pressure, which makes the wire slightly thinner and the diameter decreases. Without a proper compensation function, the grip of the grooved wire clip on the wire will decrease, resulting in stress relaxation. When the material is determined, the creep of the wire is related to time, pressure, tension and ambient temperature. The greater the pressure or tension on the wire and the higher the ambient temperature, the more serious the creep of the wire, and the change curve is exponential and increases with time. growing and increasing.
In order to maintain the stability of the holding force of the parallel groove clamp on the wire, during construction and installation, there must be enough external force to generate a suitable pressure on the wire to prevent the parallel groove clamp and the wire from loosening or relative slippage; After the external force disappears, the parallel groove clamp should be able to provide a relatively constant pressure on the wire to compensate for the creep effect of the wire caused by changes in current, temperature, wind speed, corrosion, etc.
When the bolt-type parallel groove clamp is installed, the torque applied to the bolt or nut often varies from person to person, and generally no special measuring instrument is used to check the torque, resulting in different bolts of the same clamp or between clamps installed by different personnel. The resulting stress on the wire is inconsistent. If the pressure is too large, the wire will creep too much; if the pressure is too small, the clamp and the wire will lack sufficient pressure and gripping force in the early stage of operation. The quality of the spring washer also seriously affects the mechanical stability of the clip. If a poor spring washer is selected, the plastic deformation of the spring washer will be large after being subjected to external force, which will cause the installed wire clip to not obtain the proper pressure compensation when the wire creeps.
The H-type parallel groove wire clamp is installed with special hydraulic tools, and the pressure on the wire is relatively uniform and constant. The connection with the wire is a one-time hydraulic setting, so that the inner wall material of the wire clip is embedded in the outer layer of the wire. Because the wire clip and the outer strand of the wire are the same aluminum-based material, it can reduce stress relaxation and compensate for wire creep.
The best mechanical stability should belong to the wedge-type parallel groove clamp. Due to the use of the bow-shaped structure and the wedge block, when the wire creeps due to various reasons, the bow-shaped structure and the wedge block can compensate for the creep, and the initial pressure during installation is provided by the special bullet, which can be achieved by reasonable control of the dose. goal of controlling stress

Product details


Products real shot

A corner of the production workshop


Product packaging

Product application case

 

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cable Puncture Clamp Products

Jb 16-630mm² 70-230mm Overhead Cable Parallel Groove Clamp Wire Clamp

Jbly 10-400mm² 43*36*45mm Special-Shaped Parallel Trench Wire Clamp Overhead Cable Wire Clamp

PGA 10-300mm² 34-133mm Energy-Saving Type Parallel Trench Wire Clamps for Overhead Cables

Jbly Series Parallel Splice Clamp

Jcd 16-300mm² 1.5-70mm² 150-270A Electric Meter Box Into The Household Wire Clip

Jbt 16-240mm² 60*40*35mm Overhead Cable Branch Wire Clamp Copper Parallel Trench Splicing Fitting

Popular cnkcele Products

Jls-35kv/100V 5-300A Outdoor Oil-Immersed Combination Transformer High Voltage Power Metering Box

Gw9 12/15kv New Ceramic Type Outdoor Isolation Knife Switch Disconnecting Switch

Jbcd 16-240mm² 1-20kv Overhead Insulated Power Line Puncture Grounding Wire Clip

Yh/Yhf 200/400V High Strength Rubber Sleeve Electric Welding Cable

Tbbwz 6-12kv 630A 30-900kvar Outdoor High Voltage Line Reactive Automatic Compensation Box Rod Mounted Cabinet Shunt Capacitor Complete Set

Bdgh Series 7.2-40.5kv 50ka Low Price High Voltage Current Limiting Fuses for Transformer Protection British BS Standards

Popular Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp Products

Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp

Jbtly 10-400mm² 90*75*75mm Copper-Aluminum Special-Shaped Parallel Trench Wire Clamp Overhead Cable Connection Clamp

Popular Wind Proof Fixed Clamp Products

Nxj 4× 16~50mm² 4*70~120mm² Centralized Insulation Tension Clamp Fasten Insulated Wires

Sck 35-300mm² 7.5-22.4mm Electrical Equipment Outlet Connection Clamp C-Type Temperature Measuring Clamp

Jy/Ly 35-300mm² 20-36mm Overhead Cable Connection Tube

Jcd 16-300mm² 1.5-70mm² 150-270A Electric Meter Box Into The Household Wire Clip

Jxd 35-240mm² 28*50mm Wedge-Shaped Aluminum Alloy C-Type Wire Clamp Overhead Cable Clamp

PGA 10-300mm² 34-133mm Energy-Saving Type Parallel Trench Wire Clamps for Overhead Cables

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION