XLPE Insulated ABC Cable with Aluminum Core Industrial Cable

China 
                XLPE Insulated ABC Cable with Aluminum Core Industrial Cable
              manufacture and supplier

XLPE Insulated ABC Cable with Aluminum Core Industrial Cable image

Get Latest Price Request a quote

Basic Info.

Model NO.
ABC-IEC-ASTM-BS-NFC

Conductor Material
Aluminum

Sheath Material
PVC

Insulation Material
XLPE

Material Shape
Round Wire

Range of Application
Overhead

Certification
ISO9001, CE, CCC, RoHS, VDE

Brand
Sanwu

Transport Package
Wooden Drum

Specification
1.1*1.1*1.1m/roll

Trademark
SANWU CABLE

Origin
Luoyang City, Henan Province, China

HS Code
8544492100

Production Capacity
8000kilometers/Month

Packaging & Delivery

Package Size
1100.00cm * 1100.00cm * 600.00cm

Package Gross Weight
1500.000kg

Product Description

LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, Overhead ABC cables, Conductor, AAAC, AAC, power cable etc.

SANWU CABLE owns variously advanced equipment and large quantities of high skilled professionals. With complete management system, advanced production process, strict testing procedure and reliable product quality, we have successively got IS09001, IS014001,OHSAS18001,TUV Certificate, CCC(China Compulsory Certification), the national industrial production license and so on.
In terms of quality, it
 is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-sale service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.

    Product Description

    ASTM BS CSA Standard Overhead Aluminium Conductor Aerial Bundle Cable

  ABC Cable Application
  This production is suitable for electric cable below 10KV AC, which will be mainly used for city power grid transmission line. It is simple structure, 

  safety and stable and is of good mechanism physical and electricity function. And also it has good function of proof track, creepage

  discharge, and air. Compared with naked wire, it has small gap so that can save wire route and decrease voltage drop. What is the 

  most important is that it will decrease the accident in power supplying and make people safe.

  Specific Property for ABC Cable

 1) the min. temperature of laying cable is not lower than 20°C.

 2) the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is   250°C when short circuit (5 seconds ).

 3) the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.

 4) every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours   every year.

 5) the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less   than 15(D±d) ±5%mm.

 ABC cable sketch structure as follows:

 Executive Standard:IEC   

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phase Neutral Service Connection Phase Neutral Service Connection Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Conductor UV-XLPE Conductor UV-XLPE Compact Conductor UV-XLPE
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No. of Al. Wire Overall Dia. Normal No./Dia. of Al. Wire Normal No. of Al. Wire Overall Dia. Normal
Thickness Thickness Thickness
No. X mm2 No. X mm2 No. X mm2 mm mm mm mm No./mm mm mm mm
3 X 16 1 X 50 1 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 1 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 1 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 1 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 1 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 1 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 1 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
3 X 16 1 X 50 2 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 2 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 2 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 2 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 2 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 2 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 2 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2

 Executive Standard:ASTM

Code Word AWG or k cm il Bare neutral Mes s enger Phas e conductor Weight (k g/k m )
AAAC
s trading and w ires dia(m m )
Rated Strength
(lbs )
AAC
s trading and w ires dia(m m )
ins ulation thick nes s (m m )
Bay 3*6AWG+ 1*30.58 7/ 1.68 1110 1/4.11 1.14 207
French Coach 3*6AWG+ 1*30.58 7/ 1.68 1110 7/ 1.56 1.14 2 13
German Coach 3*4AWG+ 1*48.69 7/2. 12 1760 1/5.1 9 1.14 309
Arabian 3*4AWG+ 1*48.69 7/2. 12 1760 7/ 1.96 1.14 316
Belgian 3*2AWG+ 1*77.47 7/2.67 2800 7/2.47 1.14 476
Shet land 3*1/0AWG+ 1*123.3 7/3.37 4460 19/ 1.89 1.52 768
Thoroughbred 3*2/0AWG+ 1*155.4 7/3.78 5390 19/2.13 1.52 945
Trotter 3*2/0AWG+ 1*195.7 7/4.25 6790 19/2.39 1.52 1166
Walking 3*4/0AWG+ 1*246.9 7/4.77 8560 19/2.68 1.52 1442

Executive Standard:NFC

Des cr iption

Nom inal
cros s -s ection aera
Wire num ber in Conductor Max res is tance at 20 Average diam eter of
conductor
Rated Strength Average ins ulation thick nes s
m m 2 No. Ohm /k m Min(m m ) Max(m m ) KN m m

PHASE, NEUTRAL,
and PUBLIC HIGHTING

16 7 1.91 4.6 5.1 1.9 1.2
25 7 1.2 5.8 6.3   1.4
35 7 0.868 6.8 7.3   1.6
50 7 0.641 7.9 8.4   1.6
70 12 0.443 9.7 10.2   1.8
95 19 0.32 11 12   1.8
120 19 0.253 12 13.1   1.8
150 19 0.206 13.9 15   1.7
PORTER 54.6 7 0.63 9.2 9.6   1.6
70 7 0.5 10 10.2   1.5
95 19 0.343 12.2 12.9 27.5 1.6

Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers’ requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics

Certifications

ISO9001:2008, OHSAS, CCC, TUV Certifications.

Package&Shipping:

For Package: Support to pack as rolls, or with wooden drum or wooden steel drums. 

Shipment terms: 

By FOB, CFR or CIF by sea.

By DHL, UPS, Fedex express etc are also available.

Our Services

Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.

1. Factory: 200,081 square meters, available for OEM;

2. Lead time: 5-7 working days after payment received;

3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;

4. Payment terms: T/T, L/C, O/A;

5. Guarantee: 20 years;

6. QC inspection: Strict inspection before delivery;

After-sales Service:

1. All our cables will be tested well in production and before delivery.

2. Please contact us if any problem, we will respond within 24 hours.

Customers Visiting:

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China XLPE Insulated ABC Cable with Aluminum Core Industrial Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

Overhead Stranded Wire AAC/AAAC Conductor XLPE Insulated ABC Cable

Stranded Aluminum Conductor Aerial Bundled Cables ABC Cable

Duplex Triplex Quadruplex Aluminum Service Drop and Secondary Cables

ACSR Conductor with Aluminum Core

0.6 / 1kv Aluminum Cable XLPE Insulated Cable

AAC AAAC ACSR Acar Acs Acss / Tw Galvanized Steel Wire Overhead Transmission Line Bare Aluminium Conductor

Popular dycable Products

BS Standard All Aluminum Conductor 35mm 70mm AAC Cable

International Standard XLPE Polyethylene Insulated Power Cable Manufacturer

AAC Aluminum Wires Stranding Conductor

Low-Smoke Inflaming Lsoh Retarding Thw Bvr Wire&Cable

PVC Insulation Low Voltage CCA Power Cable

Aluminum Alloy Price AAAC All Aluminium Alloy Conductor

Popular Power Cable Products

America Aluminium AA-8000 Compacted 600 Volts 3 Conductor Al Acm 600V Acwu90 Cable

Low Voltage Electrical Wire Copper Conductor XLPE Insulated Armoured PVC Sheath Power Cable

Medium Voltage Power Cable 24/36kV CU/XLPE/CWS/PVC Cable

0.6/1kv Low Voltage Aluminum 2/3/4 Cores ABC Cable Overhead Aerial Bundle Cable

IEC60502 11kv Single Core 3 X 95mm2 3 X 120mm2 Foure Cores 3 X 240mm2 Copper Conductor PVC Insulated PVC Sheathed Cable Weather Resistance

Control Cable (KVV, KVVP, KVVP2, KVV22, KVVVR)

Popular XLPE Insulated ABC Cable with Aluminum Core Industrial Cable Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION