0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable
0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Detailed Photos
- Product Parameters
- Packaging & Shipping
- Company Profile
- FAQ
- Relative products
Basic Info.
Product Description
0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable
0.6/1kv underground cable cable aluminum steel armored power cable is used for fixed industrial power applications, underground tunnels, cable trench, conduit and so on. is suitable for frequency 50HZ, 0.6/1KV and below rated voltage.
Copper XLPE Power Cable Low Voltage Power Cable is used for fixed industrial power applications, underground tunnels, cable trench, conduit and so on. is suitable for frequency 50HZ, 0.6/1KV and below rated voltage. The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force
Executive standard
CU/XLPE/SWA/PVC Low Voltage Power Cable meets the standard GB/T 12706-2008, IEC 60502-1,IEC 60228 and/or the BS, DIN and/or other types of international standards.. Also, we can produce the products according to customer’s requirements.
PVC Insulated power cable data
| 0.6/1kV-1 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 1X10 | 1.0 | 1.4 | 8.6 | 97 | 3.08 | 42 | 65 |
| 1X16 | 1.0 | 1.4 | 9.6 | 125 | 1.91 | 58 | 85 |
| 1X25 | 1.2 | 1.4 | 11.2 | 171 | 1.2 | 74 | 105 |
| 1X35 | 1.2 | 1.4 | 12.2 | 206 | 0.868 | 90 | 125 |
| 1X50 | 1.4 | 1.4 | 13.6 | 265 | 0.641 | 110 | 150 |
| 1X70 | 1.4 | 1.4 | 15.5 | 343 | 0.443 | 140 | 185 |
| 1X95 | 1.6 | 1.5 | 17.7 | 453 | 0.32 | 170 | 225 |
| 1X120 | 1.6 | 1.5 | 19.1 | 545 | 0.253 | 200 | 255 |
| 1X150 | 1.8 | 1.6 | 21 | 675 | 0.206 | 230 | 285 |
| 1X185 | 2.0 | 1.7 | 23.3 | 821 | 0.164 | 265 | 323 |
| 1X240 | 2.2 | 1.8 | 26.2 | 1044 | 0.125 | 320 | 380 |
| 1X300 | 2.4 | 1.9 | 29 | 1284 | 0.1 | 370 | 430 |
| 1X400 | 2.6 | 2 | 32.3 | 1638 | 0.0778 | 435 | 490 |
| 1X500 | 2.8 | 2.1 | 36.2 | 2063 | 0.0605 | 510 | 565 |
| 1X630 | 2.8 | 2.2 | 40 | 2515 | 0.0469 | 600 | 655 |
| 0.6/1kV-2 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 2X2.5 | 0.8 | 1.8 | 10.9 | 118 | 12.1 | 19 | – |
| 2X4 | 1 | 1.8 | 12.7 | 156 | 7.41 | 26 | – |
| 2X6 | 1 | 1.8 | 13.7 | 185 | 4.61 | 34 | – |
| 2X10 | 1 | 1.8 | 16.2 | 255 | 3.08 | 44 | 65 |
| 2X16 | 1 | 1.8 | 18.4 | 330 | 1.91 | 59 | 85 |
| 2X25 | 1.2 | 1.8 | 21.7 | 454 | 1.2 | 76 | 110 |
| 2X35 | 1.2 | 1.8 | 23.0 | 538 | 0.868 | 93 | 135 |
| 2X50 | 1.4 | 1.8 | 26.4 | 699 | 0.641 | 115 | 160 |
| 2X70 | 1.4 | 1.9 | 29.7 | 899 | 0.443 | 145 | 195 |
| 2X95 | 1.6 | 2.0 | 34.2 | 1196 | 0.32 | 170 | 235 |
| 2X120 | 1.6 | 2.1 | 37.2 | 1436 | 0.253 | 205 | 270 |
| 2X150 | 1.8 | 2.2 | 41.2 | 1776 | 0.206 | 235 | 305 |
| 2X185 | 2 | 2.4 | 45.5 | 2165 | 0.164 | 275 | 345 |
| 0.6/1kV-3 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 3X2.5 | 0.8 | 1.8 | 11.4 | 137 | 12.1 | 17 | – |
| 3X4 | 1.0 | 1.8 | 13.3 | 188 | 7.41 | 22 | – |
| 3X6 | 1.0 | 1.8 | 14.5 | 224 | 4.61 | 29 | – |
| 3X10 | 1.0 | 1.8 | 17.1 | 307 | 3.08 | 38 | 55 |
| 3X16 | 1.0 | 1.8 | 19.5 | 403 | 1.91 | 51 | 73 |
| 3X25 | 1.2 | 1.8 | 23.1 | 559 | 1.2 | 65 | 94 |
| 3X35 | 1.2 | 1.8 | 24.5 | 673 | 0.868 | 80 | 110 |
| 3X50 | 1.4 | 1.8 | 28.2 | 882 | 0.641 | 98 | 135 |
| 3X70 | 1.4 | 1.9 | 31.8 | 1150 | 0.443 | 120 | 165 |
| 3X95 | 1.6 | 2.1 | 36.6 | 1538 | 0.32 | 150 | 200 |
| 3X120 | 1.6 | 2.2 | 39.9 | 1855 | 0.253 | 180 | 230 |
| 3X150 | 1.8 | 2.3 | 44.2 | 2301 | 0.206 | 200 | 255 |
| 3X185 | 2 | 2.5 | 48.8 | 2810 | 0.164 | 235 | 290 |
| 3X240 | 2.2 | 2.7 | 55.0 | 3597 | 0.125 | 280 | 335 |
| 3X300 | 2.4 | 2.8 | 60.8 | 4428 | 0.1 | 320 | 375 |
| 0.6/1kV-4 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 4X2.5 | 0.8 | 1.8 | 12.3 | 160 | 12.1 | 17 | – |
| 4X4 | 1 | 1.8 | 14.4 | 224 | 7.41 | 22 | – |
| 4X6 | 1 | 1.8 | 15.7 | 270 | 4.61 | 29 | – |
| 4X10 | 1 | 1.8 | 18.7 | 373 | 3.08 | 38 | 55 |
| 4X16 | 1 | 1.8 | 21.3 | 494 | 1.91 | 51 | 73 |
| 4X25 | 1.2 | 1.8 | 25.3 | 692 | 1.2 | 65 | 94 |
| 4X35 | 1.2 | 1.8 | 26.9 | 838 | 0.868 | 80 | 110 |
| 4X50 | 1.4 | 1.9 | 31.2 | 1118 | 0.641 | 98 | 135 |
| 4X70 | 1.4 | 2.0 | 35.3 | 1464 | 0.443 | 120 | 165 |
| 4X95 | 1.6 | 2.2 | 40.7 | 1962 | 0.32 | 150 | 200 |
| 4X120 | 1.6 | 2.3 | 44.3 | 2371 | 0.253 | 180 | 230 |
| 4X150 | 1.8 | 2.5 | 49.2 | 2946 | 0.206 | 200 | 255 |
| 4X185 | 2 | 2.6 | 54.4 | 3603 | 0.164 | 235 | 290 |
| 4X240 | 2.2 | 2.9 | 61.3 | 4619 | 0.125 | 280 | 335 |
| 4X300 | 2.4 | 3.1 | 67.8 | 5694 | 0.1 | 320 | 375 |
| 0.6/1kV-5 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 5X2.5 | 0.8 | 1.8 | 13.3 | 195.8 | 12.1 | 22 | – |
| 5X4 | 1 | 1.8 | 15.6 | 271.3 | 7.41 | 29 | – |
| 5X6 | 1 | 1.8 | 17.1 | 320.4 | 4.61 | 38 | – |
| 5X10 | 1 | 1.8 | 20.4 | 455.3 | 3.08 | 51 | 55 |
| 5X16 | 1 | 1.8 | 23.4 | 593.7 | 1.91 | 65 | 73 |
| 5X25 | 1.2 | 1.8 | 27.9 | 837.1 | 1.2 | 80 | 94 |
| 5X35 | 1.2 | 1.9 | 29.7 | 1026.1 | 0.868 | 98 | 110 |
| 5X50 | 1.4 | 2.0 | 34.6 | 1377.5 | 0.641 | 120 | 135 |
| 5X70 | 1.4 | 2.2 | 39.2 | 1806.4 | 0.443 | 150 | 165 |
| 5X95 | 1.6 | 2.3 | 45.2 | 2425.6 | 0.32 | 180 | 200 |
| 5X120 | 1.6 | 2.5 | 49.3 | 2934.6 | 0.253 | 200 | 230 |
| 5X150 | 1.8 | 2.6 | 54.8 | 3650.9 | 0.206 | 235 | 255 |
| 5X185 | 2 | 2.8 | 60.5 | 4468.0 | 0.164 | 280 | 290 |
| 5X240 | 2.2 | 3.1 | 68.3 | 5734.5 | 0.125 | 320 | 335 |
| 5X300 | 2.4 | 3.3 | 75.5 | 7074.1 | 0.1 | 380 | 375 |
| 0.6/1kV-3+1 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 3*4+1*2.5 | 1.0/0.8 | 1.8 | 13.9 | 217 | 7.41/12.1 | 29 | – |
| 3*6+1*4 | 1.0/1.0 | 1.8 | 15.4 | 259 | 4.61/7.41 | 38 | – |
| 3*10+1*6 | 1.0/1.0 | 1.8 | 18.0 | 347 | 3.08/4.61 | 51 | 55 |
| 3*16+1*10 | 1.0/1.0 | 1.8 | 20.7 | 464 | 1.91/3.08 | 65 | 73 |
| 3*25+1*16 | 1.2/1.0 | 1.8 | 24.4 | 659 | 1.2/1.91 | 80 | 94 |
| 3*35+1*16 | 1.2/1.0 | 1.8 | 25.6 | 764 | 0.868/1.91 | 98 | 110 |
| 3*50+1*25 | 1.4/1.2 | 1.9 | 29.8 | 1025 | 0.641/1.2 | 120 | 135 |
| 3*70+1*35 | 1.4/1.2 | 2.0 | 33.3 | 1323 | 0.443/0.868 | 150 | 165 |
| 3*95+1*50 | 1.6/1.4 | 2.1 | 38.4 | 1765 | 0.32/0.641 | 180 | 200 |
| 3*120+1*70 | 1.6/1.4 | 2.2 | 42.2 | 2145 | 0.253/0.443 | 200 | 230 |
| 3*150+1*70 | 1.8/1.4 | 2.4 | 45.9 | 2537 | 0.206/0.443 | 235 | 255 |
| 3*185+1*95 | 2.0/1.6 | 2.5 | 51.0 | 3207 | 0.164/0.32 | 280 | 290 |
| 3*240+1*120 | 2.2/1.6 | 2.7 | 57.2 | 4033 | 0.125/0.253 | 320 | 335 |
| 3*300+1*150 | 2.4/1.8 | 2.9 | 63.3 | 4980 | 0.1/0.206 | 380 | 375 |
| 0.6/1kV-4+1core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 4*4+1*2.5 | 1.0/0.8 | 1.8 | 15.2 | 249 | 7.41/12.1 | 29 | – |
| 4*6+1*4 | 1.0/1.0 | 1.8 | 16.8 | 309 | 4.61/7.41 | 38 | – |
| 4*10+1*6 | 1.0/1.0 | 1.8 | 19.7 | 420 | 3.08/4.61 | 51 | 55 |
| 4*16+1*10 | 1.0/1.0 | 1.8 | 22.8 | 563 | 1.91/3.08 | 65 | 73 |
| 4*25+1*16 | 1.2/1.0 | 1.8 | 27.0 | 792 | 1.2/1.91 | 80 | 94 |
| 4*35+1*16 | 1.2/1.0 | 1.8 | 28.4 | 932 | 0.868/1.91 | 98 | 110 |
| 4*50+1*25 | 1.4/1.2 | 2.0 | 33.2 | 1282 | 0.641/1.2 | 120 | 135 |
| 4*70+1*35 | 1.4/1.2 | 2.1 | 37.3 | 1648 | 0.443/0.868 | 150 | 165 |
| 4*95+1*50 | 1.6/1.4 | 2.3 | 43.1 | 2245 | 0.32/0.641 | 180 | 200 |
| 4*120+1*70 | 1.6/1.4 | 2.4 | 47.3 | 2731 | 0.253/0.443 | 200 | 230 |
| 4*150+1*70 | 1.8/1.4 | 2.5 | 51.6 | 3229 | 0.206/0.443 | 235 | 255 |
| 4*185+1*95 | 2.0/1.6 | 2.7 | 57.5 | 4042 | 0.164/0.32 | 280 | 290 |
| 4*240+1*120 | 2.2/1.6 | 3.0 | 64.5 | 5143 | 0.125/0.253 | 320 | 335 |
| 4*300+1*150 | 2.4/1.8 | 3.2 | 71.4 | 6342 | 0.1/0.206 | 380 | 375 |
| 0.6/1kV-3+2 core aluminum conductor PVC insulated PVC sheathed power cable | |||||||
| No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
| (mm2) | (mm) | (mm) | (mm) | (kg/km) | (/km) | In Air(A) | In Ground(A) |
| 3*4+2*2.5 | 1.0/0.8 | 1.8 | 14.7 | 234 | 7.41/12.1 | 29 | – |
| 3*6+2*4 | 1.0/1.0 | 1.8 | 16.5 | 298 | 4.61/7.41 | 38 | – |
| 3*10+2*6 | 1.0/1.0 | 1.8 | 19.0 | 394 | 3.08/4.61 | 51 | 55 |
| 3*16+2*10 | 1.0/1.0 | 1.8 | 22.2 | 533 | 1.91/3.08 | 65 | 73 |
| 3*25+2*16 | 1.2/1.0 | 1.8 | 26.0 | 739 | 1.2/1.91 | 80 | 94 |
| 3*35+2*16 | 1.2/1.0 | 1.8 | 27.0 | 841 | 0.868/1.91 | 98 | 110 |
| 3*50+2*25 | 1.4/1.2 | 1.9 | 32.0 | 1212 | 0.641/1.2 | 120 | 135 |
| 3*70+2*35 | 1.4/1.2 | 2.0 | 35.4 | 1486 | 0.443/0.868 | 150 | 165 |
| 3*95+2*50 | 1.6/1.4 | 2.2 | 41.0 | 2004 | 0.32/0.641 | 180 | 200 |
| 3*120+2*70 | 1.6/1.4 | 2.3 | 45.3 | 2477 | 0.253/0.443 | 200 | 230 |
| 3*150+2*70 | 1.8/1.4 | 2.4 | 48.5 | 2859 | 0.206/0.443 | 235 | 255 |
| 3*185+2*95 | 2.0/1.6 | 2.6 | 54.4 | 3628 | 0.164/0.32 | 280 | 290 |
| 3*240+2*120 | 2.2/1.6 | 2.8 | 60.7 | 4570 | 0.125/0.253 | 320 | 335 |
| 3*300+2*150 | 2.4/1.8 | 3.0 | 67.2 | 5624 | 0.1/0.206 | 380 | 375 |
Packing :wooden drum(fumigation),steel drum,steel wooden drum or according the customer’s requirement
Shipping: Truck or train transportation or other available as required.
Luoyang Sanwu Cable Group Co., Ltd., founded in 2016 and located in the Industrial Cluster area of Yichuan,Luoyang, covers an area of more than 60,000 square meters, is an independent export-oriented enterprise, professionally engaged in design, manufacturing and trade. We specialize in the production and supply Aluminum rod, Aluminum stranded cable(AAC, AAAC,ACSR,ACAR,ACSS/AW,AACSR,ACSR/AW,AACSR/AW ACS,GWS) Overhead insulated cable,power cable, solar cable, building cable and so on, OEM also accepted.
The expanded business of our Group includes industry, Hardware, electromagnetically device, new energy equipment and auxiliary products, as well as the manufacturing and trade of municipal rescue supporting materials.
Luoyang Sanwu Cable Group Co., Ltd., has over 200 employees, five modern management workshops and 37 advanced production equipments, Aluminum rod annual output of 200, 000 tons and Cable products annual sales over 500 million.
Q:Are you a manufacturer or trading company?
A:we are manufacturer with more than 15 years history.
Q:Can you do the design for us?
A:yes,we can offer customize service.
Q:How can I get a sample to check your quality?
A:After confirmed the exactly model, we can send to you by courier.
Q:Is the sample free,and How long can I expect to get the sample?
A:the sample is free. you only needs to afford the express fees. Usually, the delivery time will within one week if we have in stock.
Q:Packaging & Shipping:
A: wooden drums ,steel drums,steel-wooden drums or according to customers’ requirement. Usually loaded in 20″ or 40″ container,shipping by sea or Railway.
Q:What about the lead time for mass production?
A:The delivery time will within 30-60 days for mass production.
Q:What is your terms of delivery?
A:EXW, FOB, CFR, CIF and so on.
| LV Power Cables – Copper Conductor IEC 60502-1 | ||
| XLPE Insulated Cable | YJV (N2XY) | CU/XLPE/PVC |
| YJY (N2X2Y) | CU/XLPE/PE | |
| YJV22 (N2XBY) | CU/XLPE/STA/PVC | |
| YJV23 (N2XB2Y) | CU/XLPE/STA/PE | |
| YJV32 (N2XRY) | CU/XLPE/SWA/PVC | |
| YJV33 (N2XR2Y) | CU/XLPE/SWA/PE | |
| LV Power Cables – Aluminum Conductor IEC 60502-1 | ||
| XLPE Insulated Cable | YJLV (NA2XY) | AL/XLPE/PVC |
| YJLY (NA2X2Y) | AL/XLPE/PE | |
| YJLV22 (NA2XBY) | AL/XLPE/STA/PVC | |
| YJLV23 (NA2XB2Y) | AL/XLPE/STA/PE | |
| YJLV32 (NA2XRY) | AL/XLPE/SWA/PVC | |
| YJLV33 (NA2XR2Y) | AL/XLPE/SWA/PE | |
| Type | Description | No. of cores | Nominal cross |
| section of conductor | |||
| YJV | Copper conductor | 1, 2, 3, 4, 3+1, | 1.5~800mm2 |
| XLPE insulation | 5, 4+1, 3+2 | ||
| PVC outer sheath Power Cable | |||
| YJY | Copper conductor | 1, 2, 3, 4, 3+1, | 1.5~800mm2 |
| XLPE insulation | 5, 4+1, 3+2 | ||
| PE outer sheath Power Cable | |||
| ZA-YJV | Copper conductor | 1, 2, 3, 4, 3+1, | 1.5~800mm2 |
| ZB-YJV | XLPE insulation flame-retardant Power Cable | 5, 4+1, 3+2 | |
| ZC-YJV | |||
| WDZA-YJY | Copper conductor | 1, 2, 3, 4, 3+1, | 1.5~800mm2 |
| WDZB-YJY | XLPE insulation Low Smoke Halogen Free | 5, 4+1, 3+2 | |
| WDZC-YJY | Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | ||
| NH-YJV | Copper conductor | 1, 2, 3, 4, 3+1, | 1.5~800mm2 |
| XLPE insulation fire-resistant Power Cable | 5, 4+1, 3+2 |
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China 0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable Products
Popular dycable Products
Power Transmission Line Electrical Power Cable AAC Cable
ASTM B232 USA Sizes 556.5mcm ACSR Osprey Conductor
BS/CSA/ASTM Standard Overhead AAC Cable/ AAC All Aluminum Conductor
BS 215 100mm2 6/4.72 7/1.57 ACSR Dog Conductor Price List
China Manufacture 9.5mm 6201 Aluminum Alloy Round Rod Aluminum Wire Rod
Aluminum Conductor Aluminum Alloy Steel Reinforced Cable
Popular Electric Cable Products
1.5mm 2.5mm Flexible PVC Wire BS 6746 Electric Cable PVC Insulated PVC Sheathed
Copper Wire Underground Armoured XLPE 0.6/1kv Power Cable Electric Cable
Na2xsy, Power Cable, 6/10 Kv, Al/XLPE/Cws/PVC (HD 620/VDE 0276-620)
High Quality PVC Flexible Electrical Ground Building Wire Cable Color 1.5mm 2.5sq mm Cable Price
450/750V Copper Conductor Al Foil Wire Shield Electrical Wire Cable
Copper Conductor PVC Coated Electrica Building Wire
Popular Power Cable Products
CSA Approved Al Armoured Electric Power Cable Type Acwu90 3 Core 500 Kcmil 600V
XLPE Cable Overhead Aerial Bundle Cable for Power Transmission
Flexible Cable Electric Cable Aluminum Conductor
Custom XLPE Insulated 8.7-15kv Power Cable Power Distribution and Transmission with High Performance
1X185mm2 Electrical XLPE Insulated Aluminium Tape Underground Power Wire Cable
Tags: 0.6/1kv-4+1 Core Copper Conductor XLPE Insulated PVC Sheathed Power Cable, dycable, Electric Cable, Power Cable