ACSR Conductor Price List ACSR 120mm2 Cable Wire Sizes
ACSR Conductor Price List ACSR 120mm2 Cable Wire Sizes image
Get Latest Price Request a quote
Basic Info.
Product Description
Customized Conductor AAC for Power Transmission Project
Applications:
Conductor(AAC, AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
2) The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
3) Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
Standards:
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
ACSR bare conductor meets/exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced
(ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel
Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced
(ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum
Conductors, Steel Reinforced (ACSR)
Technical characteristics
Standard GB/T 1179-2008
|
Area |
/ Pieces/Diameter |
Diameter | Max. resistance At 20ºC |
Calculation Force |
Weight |
| mm2 | mm | mm | Ω/km | KN | kg/km |
| 10 | 7/1.35 | 4.05 | 2.8633 | 1.95 | 27.4 |
| 16 | 7/1.71 | 5.12 | 1.7896 | 3.04 | 43.8 |
| 25 | 7/2.13 | 6.40 | 1.1453 | 4.50 | 68.4 |
| 40 | 7/2.70 | 8.09 | 0.7158 | 6.80 | 109.4 |
| 63 | 7/3.39 | 10.2 | 0.4545 | 10.39 | 172.3 |
| 100 | 19/2.59 | 12.9 | 0.2877 | 17.00 | 274.8 |
| 125 | 19/2.89 | 14.5 | 0.2302 | 21.25 | 343.6 |
| 160 | 19/3.27 | 16.4 | 0.1798 | 26.40 | 439.8 |
| 200 | 19/3.66 | 18.3 | 0.1439 | 32.00 | 549.7 |
| 250 | 19/4.09 | 20.5 | 0.1151 | 40.00 | 687.1 |
| 315 | 37/3.29 | 23.0 | 0.0916 | 51.97 | 867.9 |
| 400 | 37/3.71 | 26.0 | 0.0721 | 64.00 | 1102.0 |
| 450 | 37/3.94 | 27.5 | 0.0641 | 72.00 | 1239.8 |
| 500 | 37/4.15 | 29.0 | 0.0577 | 80.00 | 1377.6 |
| 560 | 37/4.39 | 30.7 | 0.0515 | 89.60 | 1542.9 |
| 630 | 61/3.63 | 32.6 | 0.0458 | 100.80 | 1738.3 |
| 710 | 61/3.85 | 34.6 | 0.0407 | 113.60 | 1959.1 |
| 800 | 61/4.09 | 36.8 | 0.0361 | 128.00 | 2207.4 |
| 900 | 61/4.33 | 39.0 | 0.0321 | 144.00 | 2483.3 |
| 1000 | 61/4.57 | 41.1 | 0.0289 | 160.00 | 2759.2 |
| 1120 | 91/3.96 | 43.5 | 0.0258 | 179.20 | 3093.5 |
| 1250 | 91/4.18 | 46.0 | 0.0231 | 200.00 | 3452.6 |
| 1400 | 91/4.43 | 48.7 | 0.0207 | 224.00 | 3866.9 |
| 1500 | 91/4.58 | 50.4 | 0.0193 | 240.00 | 4143.1 |
AAC Standard: ASTM B231
|
Code Name |
Total Area | / Stranding and wire diameter mm |
Linear Mass kg/km |
Overall Diameter mm |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/k |
|
| AWG or MCM | mm2 | ||||||
| Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
| Rose | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
| Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
| Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
| Poppy | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
| Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
| Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
| Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
| Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
| Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
| Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
| Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
| Peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
| Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
| Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
| Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
| Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
| Syringa | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
| Cosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
| Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
| Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
| Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
| Mistletoe | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
| Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
| Orchid | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
| Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
| Flag | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
AAC Standard: ASTM B231
|
Code Name |
Total Area | / Stranding and wire diameter mm |
Overall Diameter mm |
Linear Mass kg/mass |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/km |
|
| AWG or MCM | mm2 | ||||||
| Verbena | 700 | 354.71 | 37/3.493 | 24.45 | 978 | 5487 | 0.0813 |
| Nasturtium | 715.5 | 362.58 | 61/2.75 | 24.76 | 1000 | 5874 | 0.0795 |
| Violet | 715.5 | 362.58 | 37/3.533 | 24.74 | 1000 | 5609 | 0.0795 |
| Cattail | 750 | 380 | 61/2.817 | 25.35 | 1048 | 5985 | 0.0759 |
| Petunia | 750 | 380 | 37/3.617 | 25.32 | 1048 | 5875 | 0.0759 |
| Lilac | 795 | 402.84 | 61/2.90 | 26.11 | 1111 | 6345 | 0.0715 |
| Arbutus | 795 | 402.84 | 37/3.724 | 26.06 | 1111 | 6232 | 0.0715 |
| Snapdragon | 900 | 456.06 | 61/3.086 | 27.78 | 1257 | 6978 | 0.0632 |
| Cockscomb | 900 | 456.06 | 37/3.962 | 27.73 | 1257 | 6848 | 0.0632 |
| Goldenrod | 954 | 483.42 | 61/3.177 | 28.6 | 1333 | 7896 | 0.0596 |
| Magnolia | 954 | 483.42 | 37/4.079 | 28.55 | 1333 | 7258 | 0.0596 |
| Camellia | 1000 | 506.71 | 61/3.251 | 29.36 | 1397 | 7753 | 0.0569 |
| Hawkweed | 1000 | 506.71 | 37/4.176 | 29.23 | 1397 | 7608 | 0.0569 |
| Larkspur | 1033.5 | 523.68 | 61/3.307 | 29.76 | 1444 | 8012 | 0.0550 |
| Bluebell | 1033.5 | 523.68 | 37/4.244 | 29.72 | 1444 | 7863 | 0.0550 |
| Marigold | 1113 | 563.93 | 61/3.432 | 30.89 | 1555 | 8628 | 0.0511 |
| Hawthorn | 1192.5 | 604.26 | 61/3.551 | 31.05 | 1666 | 9245 | 0.0477 |
| Narcissus | 1272 | 644.51 | 61/3.668 | 33.02 | 1777 | 9861 | 0.0477 |
| Columbine | 1351.5 | 684.84 | 61/3.78 | 34.01 | 1888 | 10478 | 0.0421 |
| Carnation | 1431 | 725.10 | 61/3.89 | 35.03 | 1999 | 10768 | 0.0398 |
| Gladiolus | 1510.5 | 765.35 | 61/4.00 | 35.09 | 2110 | 11365 | 0.0376 |
| Coreopsis | 1590 | 805.68 | 61/4.099 | 36.51 | 2221 | 11964 | 0.0358 |
| Jessamine | 1750 | 886.71 | 61/4.302 | 38.72 | 2445 | 13168 | 0.0325 |
| Cowslip | 2000 | 1013.42 | 91/3.76 | 41.40 | 2791 | 15300 | 0.0285 |
| Lupine | 2500 | 1266.67 | 91/4.21 | 46.30 | 3524 | 18700 | 0.0230 |
| Trillium | 3000 | 1520.13 | 127/3.90 | 50.75 | 4232 | 22500 | 0.0192 |
| Bluebonnet | 3500 | 1773.50 | 127/4.21 | 54.80 | 4985 | 26200 | 0.0166 |
AAC Standard: BS215 Part 1
| Nominal Alum Area mm2 |
Stranding and wire diameter mm |
Sectional Area mm2 |
Approx. Weight Kg/km |
Overall Diameter mm |
Max..D.C. Resistance At 20ºC ≤Ω/km |
Calculated breaking load da N |
Final Modulus Of Elasticity hbar |
Coefficient of Linear Expansion /ºC |
| 22 | 7/2.06 | 23.33 | 64 | 6.18 | 1.227 | 399 | 5900 | 23×10- |
| 25 | 3/3.35 | 26.40 | 73 | 7.2 | 1.081 | 411 | 5900 | 23×10- |
| 25 | 7/2.21 | 26.8 | 73 | 6.6 | 1.066 | 459 | 5900 | 23×10- |
| 30 | 3/3.66 | 31.6 | 86 | 7.9 | 0.9082 | 486 | 5900 | 23×10- |
| 35 | 7/2.59 | 37.0 | 101 | 7.8 | 0.7762 | 603 | 5900 | 23×10- |
| 40 | 7/2.79 | 42.8 | 117 | 8.4 | 0.6689 | 687 | 5900 | 23×10- |
| 50 | 7/3.10 | 52.83 | 145 | 9.30 | 0.5419 | 828 | 5900 | 23×10- |
| 60 | 7/3.40 | 63.55 | 174 | 10.20 | 0.4505 | 990 | 5900 | 23×10- |
| 70 | 7/3.66 | 73.7 | 202 | 11.0 | 0.3881 | 1134 | 5900 | 23×10- |
| 75 | 7/3.78 | 78.5 | 215 | 11.4 | 0.3644 | 1194 | 5900 | 23×10- |
| 80 | 7/3.91 | 84.1 | 230 | 11.7 | 0.3406 | 1278 | 5900 | 23×10- |
| 90 | 7/4.17 | 95.6 | 262 | 12.5 | 0.2994 | 1453 | 5900 | 23×10- |
| 100 | 7/4.39 | 106.0 | 290 | 13.17 | 0.2702 | 1600 | 5900 | 23×10- |
| 100 | 19/2.67 | 106.0 | 293 | 13.4 | 0.2704 | 1742 | 5600 | 23×10- |
| 125 | 7/4.90 | 132.0 | 361 | 14.7 | 0.2169 | 1944 | 5900 | 23×10- |
| 150 | 7/5.36 | 157.9 | 432 | 16.1 | 0.1818 | 2385 | 5900 | 23×10- |
| 150 | 19/3.25 | 157.9 | 434 | 16.25 | 0.1825 | 2570 | 5600 | 23×10- |
| 175 | 19/3.53 | 186 | 512 | 17.7 | 0.1547 | 2863 | 5600 | 23×10- |
| 200 | 19/3.78 | 213.2 | 587 | 18.9 | 0.1349 | 3240 | 5600 | 23×10- |
| 225 | 19/3.99 | 236.9 | 652 | 20.0 | 0.1211 | 3601 | 5600 | 23×10- |
| 250 | 19/4.22 | 265.7 | 731 | 21.10 | 0.1083 | 4040 | 5600 | 23×10- |
| 300 | 19/4.65 | 322.7 | 888 | 23.25 | 0.08916 | 4875 | 5600 | 23×10- |
| 350 | 37/5.00 | 373.2 | 1027 | 25.0 | 0.07711 | 5637 | 5600 | 23×10- |
| 350 | 19/3.58 | 373.3 | 1029 | 25.1 | 0.07741 | 5745 | 5600 | 23×10- |
| 400 | 37/5.36 | 428.5 | 1179 | 26.8 | 0.06710 | 6473 | 5600 | 23×10- |
| 400 | 37/3.78 | 415.2 | 1145 | 26.46 | 0.06944 | 6310 | 5600 | 23×10- |
| 450 | 37/4.09 | 486.9 | 1342 | 28.6 | 0.05931 | 7401 | 5600 | 23×10- |
| 500 | 37/4.27 | 529.5 | 1460 | 29.9 | 0.05441 | 7998 | 5600 | 23×10- |
| 600 | 37/4.65 | 628.6 | 1733 | 32.6 | 0.04588 | 9495 | 5600 | 23×10- |
| 750 | 37/5.23 | 794.6 | 2191 | 36.6 | 0.03627 | 12010 | 5600 | 23×10- |
We can make according to your specifications, customized LOGO, with your company name on the cable.
Our Services
Luoyang Sanwu cable Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Sanwu attends International Exhibitions every year, we support to offer many kinds of wires and cables, such as xlpe/pvc electrical power cable, control power cable, aerial cable, ABC, AAC, AAAC, ACSR cables, and XLPO/PVC Solar PV Cable etc. We can produce the standard: ASTM, BS, CSA, IEC, ASMC, DIN as your need.
1. Factory: 200,081 square meters, available for OEM&ODM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: CCC,ISO9001, CQC, etc;
4. Payment terms: T/T, L/C;
5. Guarantee: 17 years;
6. QC inspection: Strict inspection before delivery;
Test Machine
extruding machine, cable-former, drawbench and so on.
Package
Wooden drum or 100m/roll
Customer
American, Australia, India, South Africa, South America…
Our Principles
1. Quality first, customer first, safety first
2. Better service, faster delivery
3. Equal and mutual benefit
4. Honest and professional
Why choose us?
1. Swift and professional response
2. Patient and trusty
3. Severe quality control system
4. On-time delivery
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China ACSR Conductor Price List ACSR 120mm2 Cable Wire Sizes manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Products
Overhead AAC/AAAC/ACSR/Acar Bare Conductor Electrical Conductor
AAC AAAC Aluminum Bare Conductor for Overhead Transmission
Aluminium Conductor AAC Electric Wire
ASTM Aluminum Alloy Conductors (AAC) Aluminum Wire B231 Standard
AAC AAAC ACSR Cable All Aluminum Stranded Conductor Cable
AAC Cables All Aluminium Stranded Conductor Overhead Line
Popular AAC Conductor Products
AAC All Aluminum Stranded Conductor, Overhead Bare Cable.
BS 215 Standard ACSR/AAC/AAAC All Aluminium Conductor
Jinshui AAC Conductor Bare Overhead Conductor
IEC61089 Standard 120mm2 AAC Conductor
Medium Voltage Twisted Cable AAAC/ACSR/AAC Overhead Conductor
AAC Cables All Aluminium Stranded Conductor Overhead Line
Popular ACSR Conductor Price List ACSR 120mm2 Cable Wire Sizes Products
Popular dycable Products
ACSR Conductor Rabbit Dog Hawk
TUV 2pfg-1169 PV1-F Solar System Xlpo Insulated 4mm Solar Cable
New Top Quality Hongliang Aerial Bundle Cable Size 1X16+16 ABC Cable
PV1-F PV Cable TUV Solar Cables
Bare Aluminum Conductor/ACSR Conductor Bare Electric Wire
High Quality ABC Cable, Aerial Bundled Cable, Duplex/Triplex/Quadruplex Cable
Tags: AAC, AAC Conductor, ACSR Conductor Price List ACSR 120mm2 Cable Wire Sizes, dycable
