Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable

China 
                        Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable
                      manufacture and supplier

Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable image

Get Latest Price Request a quote

Quick Details

Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable

overhead cable

Jinshui

ISO, CCC, CE

Aluminum , Aluminum Alloy

No Jacket

XLPE

DC Cable

Low and Medium Voltage Cable

Overhead

jin shui

Wooden Drum

as request

Zhengzhou, Hean, China

8544492100

Product Details

Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable

Application

AAC conductor electronic cable
AAC conductor electronic cable is used primarily for 600V overhead secondary distribution lines, it’s not an electrically insulated conductor and is treated as bare conductor when installed
 

 

duplex service drop
1, Application
Aerial Bundle Cable aluminum strand electronic cable is used to supply 120 volt aerial service for temporary serivce at construction sites , outdoor or street lighting . For service at 600 volt or lower at a conductor temperature of 75 degree maximum
2, Construction
Concentric strand or compressed 1350-H19 conductor , polyethylene or crosslinked polyethylene insulation , aerial bundle cable aluminum strand electrical wire concentric strand AAC , ACSR , or 6201 alloy neutral messenger

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLPE PE XLPE PE
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

3, Standards
ASTM B-230, B-231, B-232 and B-399
ICEA S-76-474
4, Note
The Designed sizes of aerial bundle cable aluminum strand electrical wire are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201Conductor temperature of 75 degree, ambient temperature of 40 degree, emissivity 0.9, 2ft/sec wind in sun
Packaging: available in 500ft coils and in long lengths on reels
The data is approximate and subject to mormal manufacturing tolerances
To determine current ampacity by conductor size, please consult the national electric code, latest edition

triplex service drop
1, Application
Aerial Bundle Cable aluminum strand electrical wire is used to supply power from the utility’s lines to consumer’s weatherhead, for service at 600 volt or less (phase to phase) at a conductor temperature of 75 degree maximum for polyethylene insulation or 90 degree maximum for crosslinked insulation
2, Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, aerial bundle cable concentric strand AAC, ACSR or 6210 alloy neutral messenger
3, Standards
ASTM B-230, B-231, B-232 and B-339
ICEA S-76-474

 

quadruplex service drop
1, Application
Aerial Bundle Cable aluminum strand electrical wire is used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made, to be used at voltage of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 degree for polyethylene insulated conductor or 90 degree for crosslinked polyethylene(XLPE) inulated conductors
2, Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum, Insulated with either polyethylene or crosslinked polyethylene , neutral messengers are concentrically stranded 6201, AAC, or ACSR , one conductor is manufactured with an extruded ridge for phase identification
3, Specifications
Quadruplex service drop of aerial bundle cable meets or exceeds the following ASTM
specifications:
B-230 aluminum wire , 1350-H19 for electrical purpose
B-231 aluminum conductors, concentric-lay-stranded
B-232 aluminum conductors, concentric-lay-stranded , coated steel reinforced (ACSR)
B-399 concentric-lay-stranded, 6201-T81 aluminum
Service Drop Cable meets or exceeds all applicable requirements of ICEA S-79-474
4, Note
The designed sizes of aerial bundle cable aluminum strand electrical wire are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201Conductor temperature of 90 degree for XLPE , 75 degree for poly , ambient temperature of 40 degree , emissivity 0.9, 2ft/sec , wind in sun
To determine current ampacity by conductor size , please consult the national electric code, latest edition

Construction

Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+

Size

(AWG)

Stranding

Insul. Thick.

(Mils)

Size

(AWG)

Stranding

Rated Strength

(lbs.)

inches XLPE PE XLPE PE
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160
                         

 

Specifications
1. ABC Cable /aerial bundled cable
2.100% factory manufacturer
3. Advance equipment
4. High quality prompt delivery

Quadruplex Service drop cable / ABC Cable / aerial bundled cable
Introduction:
ABC Cable are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. They can improves safety and reliance of electrified wire netting.

Quadruplex Service Drop:
Application: Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulation 90° C maximum for crosslinkedpolyethylene(XLPE) insulated conductors.

Additional description:
All the products can perfectly meet requests of different standards.
At the same time, we can design and manufacture special cables according to the required standards of custom.

Cores Nominal cross-sectional area Phase Conductors
insulation
Dia. Of cable R. of conductors at 20°C Break strength of conductor
Ω/km KN
3C+1C mm2 Thickness (mm) mm Phase cores Neutral cores Phase cores Neutral cores
3C+1C 3×25+54.6 1.4 23.57 1.2 0.630 16.6 16.6
3C+1C 3×35+54.6 1.6 26.08 0.868 0.630 16.6 16.6
3C+1C 3×50+54.6 1.6 28.15 0.641 0.630 16.6 16.6
3C+1C 3×70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3×70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3×70+70 1.8 32.75 0.443 0.500 20.5 20.5
3C+1C 3×95+70 1.8 35.78 0.32 0.500 20.5 20.5
3C+1C 3×120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3×120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3×120+95 1.8 39.26 0.253 0.343 27.5 27.5
3C+1C 3×150+95 1.9 41.81 0.206 0.343 27.5 27.5

We are China Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

XLPE Insulation Overhead ABC Cable Aluminum Conductor

ABC Cable --Aerial Bundled Cable

Parallel or Twisted Aerial Bundle Cable ABC Cable

Low Voltage 0.6/1kv ABC Cable for Overhead Use

ABC Twisted Cable-Triplex Aluminum Wire Stranded Cable

Aluminum, ACSR, AAC Conductor XLPE PVC Overhead Aerial Bundled Cable ABC Cable

Popular Aerial Bundle Cable Products

Aluminum Conductor ABC Overhead Cable, Electric Cable

0.6/1kv Duplex/Triple Aluminum Conductor Aerial Bundled Cable

Aeroprex Rz Cu / Xs - Aerial Bundle Cable 0.6/1 Kv

Overhead Triplex Service Drop Aerial Bundle Cable

0.6kv/1kv/36kv PVC/XLPE/PVC Electric Power Cable Areial ABC/AAC/ACSR Conductor Concentric Solid

ACSR 340/30 380/50 385/35 435/55 450/40 490/65

Popular Aluminum Cable Products

Duplex Service Drop Aluminum Cable 2*6 AWG

Bare Aluminum Conductor Steel Reinforced ACSR Rabbit

XLPE Insulated Aerial Bundled Cable 0.6-1kv

Eay2y-J Power Cable 0, 6/1kv with Al Conductors PVC Insulated HDPE Sheathed

Armigron-M Rvmv Low Voltage Energy Distribution Fire Retardant Cable

Quadruplex Service Drop ABC Cable AWG Standard

Popular jsgroup Products

Swa / Sta Aluminum Conductor PVC Power Cable

12AWG 10AWG Nylon Thhn/Thwn Electrical Wires Copper Core PVC Insulated Wire Cable

Single Two Core 8000 Series Aluminum Alloy or Copper Conductor Concentric Cable

ABC Cable AAC/XLPE+AAAC

Electric Wire 450/750V Copper / PVC Wire IEC 60227

450/750V Copper Conductor PVC Insulated Wire

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION