Aluminium Urd Cable XLPE/PE Insulation
Aluminium Urd Cable XLPE/PE Insulation image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
|
Code Name |
Phase Conductor |
Neutral |
Single Phase Conductor(in) |
Outside diameter(in) |
Weight Per 1000ft (lbls) |
Ampacity |
|||||
|
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Insulation Thickness (mls) |
Direct Burial |
In Duct |
||||
|
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
|
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
|
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
|
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
|
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
|
Syracuse |
2/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
|
Lafayette |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.367 |
720 |
225 |
170 |
|
Swarthmore |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.430 |
805 |
250 |
195 |
|
Davidson |
3/0 |
19/w |
80 |
3/0 |
19/w |
80 |
.616 |
1.487 |
874 |
250 |
195 |
|
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
|
Earlham |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.623 |
1066 |
290 |
225 |
|
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1544 |
385 |
305 |
|
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2174 |
467 |
420 |
|
Windham |
750 |
61/w |
110 |
500 |
37/w |
95 |
.979 |
2.850 |
2542 |
615 |
492 |
We are China Aluminium Urd Cable XLPE/PE Insulation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Quadruplex Service Drop Aluminum Conductors AAAC 6201 Alloy Neutral-Messenger Cable
Aluminum Conductor Steel Reinforced ACSR Rabbit Conductor
Aluminium Alloy Electrical Wire XLPE Insulated ABC Cable
Service Drop Cable Twisted Aluminum Overhead ABC Cable
Cable XLPE Overhead ABC Cable Aluminum SIP4 SIP2 SIP 4*10 4*16 4*25 4*35 2AWG 1/0AWG
Popular huatongcable Products
Overhead Triplex Service Drop Apus Aerial Bundled Cable for Transmission Line
Best Quality Lowest Price AAAC All Aluminum Alloy Conductor
AAAC Conductor ASTM B399 Aluminium Alloy 6201-T81 500mm2
Four Cores with Stranded Alumininum Conductors XLPE Insulated Power Cable
Overhead Quadruplex Service Drop Palomino Aerial Bundled Cable for Transmission Line
11kv 25kv 36kv Spaced Aerial Cable Sac Cable 95 120 150 185mm2
Popular Powe Cable Products
0.6/1kv 3 Cores Aluminum /PVC Insulated Power Cable
Multi Cores Aluminum Cores PVC Insulated Power Cable
ASTM Standard Bare Aluminum Alloy Cable 350mcm AAAC Conductor
Power Distribution Aluminium Urd Cable
ABC Cable Aerial Bunched/Bundled Cable
Power Distribution Aerial Isolated ABC Cable
Popular Urd Cable Products
35kv Single Core Aluminum Conductor XLPE Insulated Urd Cable
15kv 35 Kv Urd Cable 1/0 2/0 3/0 4/0 AWG Power Cable
15kv One Third Copper Wire Shield Trxlpe Insulation Mv90 Cable
1*120mm2 Mv XLPE Insulated Underground Cable
220 Mil EPR 15 KV Urd Cable 100% Insulation Level with UL1072 Certificate
20kv Underground Distribution Line Aerial Primary Secondary Cable
Tags: ABC Cable, huatongcable, Powe Cable, Urd Cable