NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger

China 
                        NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger
                      manufacture and supplier

NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger image

Get Latest Price Request a quote

Quick Details

NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger

ABC Cable

Huatong

Jklv

ISO, CCC, CE, UL

Aluminium/Copper

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Underground, Industrial, Power Station

PVC/PE/XLPE

40000m2

Power Distribution

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.

ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. 

ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.

ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
   For XLPE insulation is 250°C.
   For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+
Size
(AWG)
Stranding Insul. Thick.
(Mils)
Size
(AWG)
Stranding Rated Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234

We are China NF C 33-209 Aerial Bundled Cable Phase Conductor Lighting Conductor AAAC Messenger manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular AAAC Messenger Products

NFC33-209 ABC Cable 3 Cover with AAAC Messenger

1kv Triplex Aerial Bundled Cable AAAC Messenger Lepas

Popular Aerial Bundled Cable Products

UL Certified Hot Sell Underground Distribution Cable Urd

LV Aluminium Conductor PE/XLPE Insulated ABC Cable

Low Voltage XLPE Insulated Conductor ABC Bare Cable

Quadruplex Service Drop Cable Aluminum Conductor Concentric-Lay-Stranded ABC Cable

3*70+1*54.6mm2 Aluminum Norme NFC33-209 Insulation 0.6/1kvaerial Bundle Cable

Aerial Bundled XLPE Insulated Aluminum Lxs Cable 4X50+1X25mm2

Popular huatongcable Products

Overhead/Aluminum/ABC/AAC/AAAC/ACSR/Aerial Bundled Cable

0.6kv/1kv Aerial Bunched Triplex Service Drop Cable 3/0 AWG Flustra

NFC 33-209 Low Voltage ABC Cable 3X25+54.6+1X16mm2

Underground Use Cable XLPE Insulation ACSR Core ASTM Urd Cable

High Quality Aluminum Clad Steel Strand Wire Acs for Electrical Transmission

Rated Voltage 1kv 3kv PVC Insulated Flame Retardant Power Cable

Popular NF C 33-209 Products

Aerial Bundle Aluminum Insulated Conductors, 3x70 mm2+ 54.6mm2 Neutral Messenger

LV Aerial Bundled Cable ABC Three Phase Aluminum Conductor 3X50+1X54.6mm2 600/1000V

0.6/1kV 3X70+1X54,6mm2 Twisted ABC Aerial Bundled Overhead Cable NF C 33-209

ABC Cable 3X70mm2+1X50mm2 0.6/1kV Low Voltage Aerial Bundled Cable

0.6/1kV 3X25+1X54,6mm2 Twisted Alu ABC Aerial Bundled Overhead Cable NF C 33-209

Aerial Bundle Aluminum Insulated Conductors, 3x50 mm2+ 54.6mm2 Neutral Messenger

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION