American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power

China 
                        American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power
                      manufacture and supplier

American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power image

Get Latest Price Request a quote

Quick Details

American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power

URD Cable

Huatong

Jklv

ISO, CCC, CE, UL

Aluminium

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

PVC/PE/XLPE

40000m2

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

We are China American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 0.6kv/1kv Products

  • No related articles
  • Popular huatongcable Products

    IEC60502-2 XLPE Insualted Armoured Underground 6/10kv Copper Cable 3X50mm2

    Bare Aluminium Conductor Alloy Reinforced with ASTM Standard

    Overhead Triplex Service Drop Barnacles Aerial Bundled Cable for Transmission Line

    AAC-Conductor Aerial Bundled Cable, Service Drop ABC Cable

    Bare Overhead Aluminum Conductor Aluminium Alloy Reinforced Acar ASTM B524

    Overhead Quadruplex Service Drop Belgian Aerial Bundled Cable for Transmission Line

    Popular Service Drop Cable Products

    ABC Cable, Insulated Aerial Cable, Aerial Bundled Cable

    Overhead Service Aerial Bundled Cable ABC Cable

    Overhead Aluminum Service Drop Cable NF C 33-209 ABC Cable

    Low Voltage Aluminum Conductor PVC Insulation Overhead Electric Transmission Quadruplex Service Drop Aerial Bundled Cable 4X185mm2 ABC Cable

    Triplex Service Drop Cable with AAAC Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)

    Service Drop Cable Twisted Aluminum Overhead ABC Cable

    Popular Urd Cable Products

    The High Quality 3 Core 600V XLPE Overhead Aluminium Urd Cable

    Low Voltage LV 4core XLPE Insulated Underground Urd Power Cable

    UL Certificate Approved Urd Cable 1/0 2/0 4/0 Triplex Converse Sweetbriar in Us Market Second Underground Distribution Cable

    UL Certificate 28 Kv Al/Tr-XLPE/One Third Neutral/PVC Urd Cable (AEIC CS 8/ICEA S-94-649)

    China Manufacturer UL Certificate 5 Kv to 35 Kv 100% and 133% Mv-90 XLPE Insulated PVC Jacketed Copper Wire Shield Urd Cable Mv90 Aluminum Conductor

    600V Single Conductor Urd Power Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION