American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power
American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
We are China American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6kv/1kv Products
Popular huatongcable Products
IEC60502-2 XLPE Insualted Armoured Underground 6/10kv Copper Cable 3X50mm2
Bare Aluminium Conductor Alloy Reinforced with ASTM Standard
Overhead Triplex Service Drop Barnacles Aerial Bundled Cable for Transmission Line
AAC-Conductor Aerial Bundled Cable, Service Drop ABC Cable
Bare Overhead Aluminum Conductor Aluminium Alloy Reinforced Acar ASTM B524
Overhead Quadruplex Service Drop Belgian Aerial Bundled Cable for Transmission Line
Popular Service Drop Cable Products
ABC Cable, Insulated Aerial Cable, Aerial Bundled Cable
Overhead Service Aerial Bundled Cable ABC Cable
Overhead Aluminum Service Drop Cable NF C 33-209 ABC Cable
Triplex Service Drop Cable with AAAC Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)
Service Drop Cable Twisted Aluminum Overhead ABC Cable
Popular Urd Cable Products
The High Quality 3 Core 600V XLPE Overhead Aluminium Urd Cable
Low Voltage LV 4core XLPE Insulated Underground Urd Power Cable
UL Certificate 28 Kv Al/Tr-XLPE/One Third Neutral/PVC Urd Cable (AEIC CS 8/ICEA S-94-649)
600V Single Conductor Urd Power Cable
Tags: 0.6kv/1kv, huatongcable, Service Drop Cable, Urd Cable