Product Details

0.6/1KV, 1.8/1KV, 3.6/6KV, 6/10K, 8.7/15KV, 12/20KV, 18/30KV, 26/35KV XLPE insulated flame retardant
Power Cable
Standards
Products can be manufactured according to GB standard, IEC standard, ASTM standard, BS standard and DIN and other standard and customers` specific requirements.

Specification
1. Conductors: Copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
4. PVC or XLPE sheathed.
5. Number of cable cores: One core (Single core), two cores(Double cores), three cores, four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core), five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).

Characteristics of Cable
1. Max Long-time operating temperature of PVC insulated cable is 70° C, XLPE 90° C
2. Installing temperature of cable should not be less than 0° C
3. Max short-circuit temperature is: PVC not exceed 160° C, XLPE 250° C, Not more than5 Sec.
4. Permitting bending radius cable: Not less than 10 D times (D: External diameter of cable)
5. Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.

Number of Cores & Nominal Cross-section Area

Installation:
1. The installation temperature should not over 20º C, If the ambient temperature is lower than 0º C, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 35kv D. C.

In air:
1. As the single core cable laying in parallel, the distance between the cable’s center is 2 times (for cables which cross section area of conductor ≤ 185mm2) and
90mm (for cables which cross sectional area of conductor≥ 240mm2)
2. Ambient temperature: 30º C
3. Max. Temperature of conductor: 70º C
4. Rating factors of current rating for ambient temperature:

Direct in ground:
1. When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.
2. Ambient temperature: 25º C.
3. Max. Temperature of conductor: 70º C.
4. Soil thermour resistivity: 1.0º C. M/w.
5. Depth: 0.7m
6. Rating factors under different ambient temp.:

PVC Insulation Electric Cable

XLPE Insulated electric cable

We are China Flexible Cable Flat Cable Four Cores Annealed Copper Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Annealed Copper Products

38 mm2 Bare Soft Copper Grounding Conductor Stranded PNS 1207

125 mm2 Bare Soft Copper Grounding Conductor Stranded

185 mm2 Bare Soft Copper Grounding Conductor Stranded

Solid Conductor #6AWG Annealed Copper Jumper Wire ASTM B3 for Distribution Lines

25mm Earth Cable Stranded Plain Annealed Copper Conductor

Popular Flat Cable Products

Africa& UK Twin and Earth Cable 6242y Cable Nigeria 2X2.5+1.0mm Flat Electro Cables

IEC Standard Flexible Power Cable Stranded Electric Cable Wire Electrical Building Wire

Flat Rubber Cable

750 V Building Wire Flat Cable

PVC Insulated 1/1.5/2.5mm 2 3 Core 2+E Solid Copper Stranded Copper Flat Twin and Earth Cable Electrical Wire

450/750V 2.5mm Electrical Wire Flat TPS Twin and Earth Cable

Popular huatongcable Products

Rabbit, Dog, Lynx, Racoon, Otter ACSR Conductor with BS Standard

All Aluminum Alloy Conductor AAAC ASTM BS IEC DIN CSA 4AWG

35mm2 Service Cable Solid Aluminum Cable with Copper Pilot Wires

High Voltage Aluminum Conductortape Armoured 220kv Power Cable (1-1000)

Overhead Quadruplex Service Drop Thoroughbred Aerial Bundled Cable for Transmission Line

Face Mask KN95 Protection

Popular Power Cable Products

XLPE Corrugated Aluminum Alloy Copper Sheath Electric Lsoh Flexible Mine Mining Cable

6AWG 13.3sqmm All Aluminum Alloy Conductor AAAC Conductor with Grease

Al/PVC/Swa/PVC, 0.6/1 Kv, Steel Wire Armored Power Cable (IEC 60502-1)

XLPE Insulated 3c 400mm2 185mm2 120mm2 Na2xsa2y 6 Kv 10kv, 20kv, 35 Kv Power Cable

10kv 22kv 11kv Medium Voltage Cu XLPE PVC Insulated Swa Armored Underground Power Cable in Kenya

Electrical Flexible Cable, PVC Insulated PVC Sheathed Control Flexible Cable.

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION