Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Terrier
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Terrier image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Specification
| Duplex service drop | |||||||||
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
| Bare | OD | ||||||||
| AAC | |||||||||
| Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
| Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
| Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
| Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
| Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
| Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
| Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
| Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
| Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| AAAC | |||||||||
| Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
| VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
| Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
| Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
| Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
| Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| ACSR | |||||||||
| Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
| Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
| Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
| Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
| Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
| Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
| Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
| Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
| Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| DESCRIPTION | INSULATED PHASE CONDUCTORS | Average Insulation Thickness | ||||
| Type | Nominal cross-section area | Wire Number in the conductor | Max. resistance at 20 o C | Average diameter of conductors | Rated Strength | |
| mm 2 | Number | Ohm/km | Mini mm Max. mm | Mini KN | mm | |
| PHASE, NEUTRAL, and PUBLIC LIGHTING |
16 | 7 | 1.910 | 4.6 5.1 | 1.9 | 1.2 |
| 25 | 7 | 1.200 | 5.8 6.3 | 3.0 | 1.4 | |
| 35 | 7 | 0.868 | 6.8 7.3 | – | 1.6 | |
| 50 | 7 | 0.641 | 7.9 8.4 | – | 1.6 | |
| 70 | 12 | 0.443 | 9.7 10.2 | – | 1.8 | |
| 95 | 19 | 0.320 | 11.0 12.0 | – | 1.8 | |
| 120 | 19 | 0.253 | 12.0 13.1 | – | 1.8 | |
| 150 | 19 | 0.206 | 13.9 15.0 | – | 1.7 | |
| PORTER | 54.6 | 7 | 0.630 | 9.2 9.6 | 16.6 | 1.6 |
| 70 | 7 | 0.500 | 10.0 10.2 | 20.5 | 1.5 | |
| 95 | 19 | 0.343 | 12.2 12.9 | 27.5 | 1.6 | |
We are China Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Terrier manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable 4 AWG Terrier Products
Popular Duplex 4 AWG Terrier Cable Products
Popular Factory Price Duplex Service Drop Products
Factory Price Duplex Service Drop Cable ABC Cable 4AWG Dachshund
Factory Price Duplex Service Drop Cable ABC Cable 1/0 AWG Bull
Factory Price Duplex Service Drop Cable ABC Cable 1AWG Airedale
Factory Price Duplex Service Drop Cable ABC Cable 2AWG Doberman
Factory Price Duplex Service Drop Cable ABC Cable 1/0 AWG Malemure
Factory Price Duplex Service Drop Cable ABC Cable 1/0 AWG Basset
Popular huatongcable Products
IEC60502-2 Aluminum XLPE Insualted 12/20kv 3X50mm2 Armored Underground Cable
Bare ACSR Aluminum Cable Conductor IEC/BS/DIN/ASTM/CSA, ACSR Stranded Conductor
AAC Overhead Cable All Aluminum Strand Conductor for Transmission Use
Low Voltage Overhead Cable Aluminium Bare Conductor AAAC
Bare Overhead Conductor ACSR150/25 with DIN 48204 Standard,
Tags: Cable 4 AWG Terrier, Duplex 4 AWG Terrier Cable, Factory Price Duplex Service Drop, huatongcable